Hybrid Graphene/Gold Plasmonic Fiber-Optic Biosensor

被引:60
|
作者
Zhang, Nancy Meng Ying [1 ,2 ]
Li, Kaiwei [1 ,2 ]
Shum, Perry Ping [1 ,2 ]
Yu, Xuechao [1 ,2 ]
Zeng, Shuwen [1 ,2 ]
Wu, Zhifang [1 ,2 ]
Wang, Qi Jie [1 ,2 ]
Yong, Ken Tye [1 ,2 ]
Wei, Lei [1 ,2 ]
机构
[1] Nanyang Technol Univ, Sch Elect & Elect Engn, 50 Nanyang Ave, Singapore 639798, Singapore
[2] CINTRA CNRS NTU THALES, UMI3288, Res Techno Plaza,50 Nanyang Dr, Singapore 637553, Singapore
来源
ADVANCED MATERIALS TECHNOLOGIES | 2017年 / 2卷 / 02期
关键词
OXIDE; NANOSTRUCTURES; SENSITIVITY; MODULATION;
D O I
10.1002/admt.201600185
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
A 2D material/metal hybrid plasmonic sensor is demonstrated by direct integration of graphene layer on gold-coated optical fiber. Both linear response to wide range ssDNA concentration from 1 x 10(-12) to 10 x 10(-6)m and low detection limit of 1 x 10(-12)m are achieved. The resulting hybrid plasmonic sensor shows prospects of highly sensitive, highly integrated, and flexible sensing at fiber-optic length scale.
引用
收藏
页数:6
相关论文
共 50 条
  • [21] A fiber-optic microarray biosensor using aptamers as receptors
    Lee, M
    Walt, DR
    ANALYTICAL BIOCHEMISTRY, 2000, 282 (01) : 142 - 146
  • [22] Fluorescence enhancements of fiber-optic biosensor with metallic nanoparticles
    Ng, Ming-Yaw
    Liu, Wei-Chih
    OPTICS EXPRESS, 2009, 17 (07): : 5867 - 5878
  • [23] Quantifying serum antiplague antibody with a fiber-optic biosensor
    Anderson, GP
    King, KD
    Cao, LK
    Jacoby, M
    Ligler, FS
    Ezzell, J
    CLINICAL AND DIAGNOSTIC LABORATORY IMMUNOLOGY, 1998, 5 (05) : 609 - 612
  • [24] A chemiluminescence fiber-optic biosensor for detection of DNA hybridization
    Zhang, GJ
    Zhou, YK
    Yuan, JW
    Ren, S
    ANALYTICAL LETTERS, 1999, 32 (14) : 2725 - 2736
  • [25] Fiber-optic microbial biosensor for organophosphorus pesticides.
    Kaneva, I
    Chen, W
    Mulchandani, A
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 1998, 216 : U248 - U248
  • [26] Adaptation of a fiber-optic biosensor for use in environmental monitoring
    Pease, MD
    ShriverLake, L
    Ligler, FS
    BIOSENSOR AND CHEMICAL SENSOR TECHNOLOGY: PROCESS MONITORING AND CONTROL, 1995, 613 : 33 - 43
  • [27] A disposable fiber-optic plasmonic sensor for chemical sensing
    Han, Tao
    Zhang, Cheng
    Yu, Hui
    Li, Jinghong
    ANALYTICAL BIOCHEMISTRY, 2025, 696
  • [28] Fiber-optic Lorentz force magnetometer based on a gold-graphene composite membrane
    Liu, Zeng-yong
    Cao, Hong-qian
    Xu, Fei
    APPLIED PHYSICS LETTERS, 2018, 112 (20)
  • [29] Sensitivity enhancement of fiber-optic biosensor by localized surface plasmon-coupled emission with gold nanoparticles
    Chang, Ying-Feng
    Hsieh, Bao-Yu
    Chen, Hsiang-Yin
    Ng, Ming-Yaw
    Liu, Wei-Chih
    Chung, Yung-Chang
    Wu, Hsieh-Ting
    Chou, Chien
    NANOSCALE IMAGING, SPECTROSCOPY, SENSING, AND ACTUATION FOR BIOMEDICAL APPLICATIONS IV, 2007, 6447
  • [30] Design and numerical analysis of a graphene-coated fiber-optic SPR biosensor using tungsten disulfide
    Rahman, M. Saifur
    Noor, Shaikh Sumit
    Anower, M. S.
    Abdulrazak, Lway Faisal
    Rahman, Md. Maksudur
    Rikta, K. A.
    PHOTONICS AND NANOSTRUCTURES-FUNDAMENTALS AND APPLICATIONS, 2019, 33 : 29 - 35