Photon extremity absorbed dose and kerma conversion coefficients for calibration geometries

被引:3
|
作者
Veinot, K. G. [1 ]
Hertel, N. E. [1 ]
机构
[1] Georgia Inst Technol, George W Woodruff Sch Mech Engn, Atlanta, GA 30332 USA
来源
HEALTH PHYSICS | 2007年 / 92卷 / 02期
关键词
dose; absorbed; photons; extremities; dosimetry; personnel;
D O I
10.1097/01.HP.0000243165.43316.78
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Absorbed dose and dose equivalent conversion coefficients are routinely used in personnel dosimetry programs. These conversion coefficients can be applied to particle fluences or to measured air kerma values to determine appropriate operational monitoring quantities such as the ambient dose equivalent or personal dose equivalent for a specific geometry. For personnel directly handling materials, the absorbed dose to the extremities is of concern. This work presents photon conversion coefficients for two extremity calibration geometries using ringer and wrist/arm phantoms described in HPS N13.32. These conversion coefficients have been calculated as a function of photon energy in terms of the kerma and the absorbed dose using Monte Carlo techniques and the calibration geometries specified in HPS N13.32. Additionally, kerma and absorbed dose conversion coefficients for commonly used x-ray spectra and calibration source fields are presented. The kerma values calculated in this work for the x-ray spectra and calibration sources compare well to those listed in HPS N13.32. The absorbed dose values, however, differ significantly for higher energy photons because charged particle equilibrium conditions have not been satisfied for the shallow depth. Thus, the air-kerma-to-dose and exposure-to-dose conversion coefficients for Cs-137 and Co-60 listed in HPS N13.32 overestimate the absorbed dose to the extremities. Applying the conversion coefficients listed in HPS N13.32 for Cs-137, for example, would result in an overestimate of absorbed dose of 62% for the ringer phantom and 55% for the wrist phantom.
引用
收藏
页码:179 / 185
页数:7
相关论文
共 50 条
  • [1] RELATION BETWEEN KERMA AND ABSORBED DOSE IN PHOTON BEAMS
    NILSSON, B
    BRAHME, A
    ACTA RADIOLOGICA ONCOLOGY, 1983, 22 (01): : 77 - 85
  • [2] Photon dose conversion coefficients for human teeth in standard irradiation geometries
    Ulanovsky, A
    Wieser, A
    Zankl, M
    Jacob, P
    HEALTH PHYSICS, 2005, 89 (06): : 645 - 659
  • [3] A comparison of Australian and Canadian calibration coefficients for air kerma and absorbed dose to water for 60Co γ radiation
    Shortt K.R.
    Huntley R.B.
    Kotler L.H.
    Boas J.F.
    Webb D.V.
    Australasian Physics & Engineering Sciences in Medicine, 2006, 29 (2): : 206 - 215
  • [4] ABSORBED DOSE VERSUS KERMA
    ROSSI, HH
    HEALTH PHYSICS, 1965, 11 (08): : 779 - +
  • [5] INTERNAL CONVERSION COEFFICIENTS FOR ABSORBED DOSE CALCULATIONS
    WIDMAN, JC
    POWSNER, ER
    PHYSICS IN MEDICINE AND BIOLOGY, 1970, 15 (01): : 99 - &
  • [6] Absorbed dose rate conversion coefficients for reference terrestrial biota for external photon and internal exposures
    Taranenko, V
    Pröhl, G
    Gómez-Ros, JM
    JOURNAL OF RADIOLOGICAL PROTECTION, 2004, 24 (4A) : A35 - A62
  • [7] CALIBRATION OF INDIVIDUAL DOSIMETERS BY THE ABSORBED DOSE OF PHOTON RADIATION
    BAKULIN, YP
    BASHMAKOV, VP
    BOGDANOV, EA
    GIMADOVA, TI
    MURATOV, NI
    TULTAEV, AV
    SOVIET ATOMIC ENERGY, 1984, 56 (03): : 201 - 203
  • [9] Absorbed dose conversion factors for megavoltage photon beams
    Nutbrown, R
    Duane, S
    Shipley, D
    Thomas, R
    ADVANCED MONTE CARLO FOR RADIATION PHYSICS, PARTICLE TRANSPORT SIMULATION AND APPLICATIONS, 2001, : 299 - 304
  • [10] CONVERSION COEFFICIENTS FROM FLUENCE AND AIR KERMA TO DOSE EQUIVALENT QUANTITIES
    ROSSITER, MJ
    BRITISH JOURNAL OF RADIOLOGY, 1990, 63 (747): : 230 - 230