A g-Factor Metric for k-t SENSE and k-t PCA Based Parallel Imaging

被引:4
|
作者
Binter, Christian [1 ,2 ]
Ramb, Rebecca [3 ]
Jung, Bernd [3 ,4 ]
Kozerke, Sebastian [1 ,2 ,5 ]
机构
[1] Univ Zurich, Inst Biomed Engn, Gloriastr 35, CH-8092 Zurich, Switzerland
[2] ETH, Gloriastr 35, CH-8092 Zurich, Switzerland
[3] Univ Med Ctr, Dept Diagnost Radiol, Med Phys, Freiburg, Germany
[4] Univ Hosp Bern, Inst Diagnost Intervent & Pediat Radiol, Bern, Switzerland
[5] Kings Coll London, Imaging Sci & Biomed Engn, London WC2R 2LS, England
基金
瑞士国家科学基金会;
关键词
parallel imaging; g-factor; noise estimation; temporal filtering; k-t SENSE; k-t PCA; DYNAMIC MRI; NOISE RATIO; BLAST RECONSTRUCTION; PHASED-ARRAY; COIL ARRAYS; GRAPPA; UNFOLD; EFFICIENCY; SNR;
D O I
10.1002/mrm.25606
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To propose and validate a g-factor formalism for k-t SENSE, k-t PCA and related k-t methods for assessing SNR and temporal fidelity. Methods: An analytical g(xf)-factor formulation in the spatiotemporal frequency domain is derived, enabling assessment of noise and depiction fidelity in both the spatial and frequency domain. Using pseudoreplica analysis of cardiac cine data the gxf-factor description is validated and example data are used to analyze the performance of k-t methods for various parameter settings. Results: Analytical gxf-factor maps were found to agree well with pseudoreplica analysis for 3x, 5x, and 7x k-t SENSE and k-t PCA. While k-t SENSE resulted in lower average g(xf) values (g(x)(avg)) in static regions when compared with k-t PCA, k-t PCA yielded lower g(x)(avg) values in dynamic regions. Temporal transfer was better preserved with k-t PCA for increasing under-sampling factors. Conclusion: The proposed gxf-factor and temporal transfer formalism allows assessing noise performance and temporal depiction fidelity of k-t methods including k-t SENSE and k-t PCA. The framework enables quantitative comparison of different k-t methods relative to frame-by-frame parallel imaging reconstruction. (C) 2015 Wiley Periodicals, Inc.
引用
收藏
页码:562 / 571
页数:10
相关论文
共 50 条
  • [21] BURNING AT THE K-T BOUNDARY
    HECHT, J
    NEW SCIENTIST, 1993, 139 (1885) : 16 - 16
  • [22] PLANTS AND THE K-T BOUNDARY
    Nichols, D. J.
    Johnson, K. R.
    PALYNOLOGY, 2008, 32 : 265 - 266
  • [23] Gaps in the K-T record
    Archibald, JD
    SCIENCE, 1998, 279 (5354) : 1114 - 1115
  • [24] SEDIMENTOLOGY OF THE K-T BOUNDARY
    CLIFTON, HE
    DOTT, RH
    SCIENCE, 1994, 264 (5167) : 1829 - 1829
  • [25] k-t BLAST reconstruction from non-Cartesian k-t space sampling
    Hansen, MS
    Baltes, C
    Tsao, J
    Kozerke, S
    Pruessmann, KP
    Eggers, H
    MAGNETIC RESONANCE IN MEDICINE, 2006, 55 (01) : 85 - 91
  • [26] Improved k-t BLAST for fast fMR imaging
    Sinha, Neelam
    Saranathan, Manojkumar
    Ramakrishnan, A. G.
    JOURNAL OF MAGNETIC RESONANCE, 2010, 204 (02) : 273 - 280
  • [27] K-T EVENT DEBATED - CONCLUSION
    HSU, KJ
    GEOTIMES, 1982, 27 (07): : 26 - 27
  • [28] K-T meteorite relics found
    不详
    CURRENT SCIENCE, 1997, 72 (04): : 232 - 233
  • [29] Cartesian SENSE and k-t SENSE reconstruction using commodity graphics hardware
    Hansen, Michael S.
    Atkinson, David
    Sorensen, Thomas S.
    MAGNETIC RESONANCE IN MEDICINE, 2008, 59 (03) : 463 - 468
  • [30] K-T BOUNDARY ISSUES - REPLY
    KERR, RA
    SCIENCE, 1994, 264 (5159) : 642 - 642