摘要
Power transformers are one of the key apparatus in electric power networks. To ensure the reliability of power transformers, the diagnosis of mechanical faults, such as the deformation and displacement of windings, is important. Frequency response analysis (FRA) has attracted considerable attention as a diagnostic method for mechanical faults of power-transformer windings. In FRA, the frequency responses of power transformers, namely, transfer functions (TFs), are measured in a wide frequency range. Faults are detected by detecting changes in TFs compared with reference data measured when the power transformers were operating normally. Therefore, it is important to ensure the repeatability of measurements. In this study, the TFs of two power transformers are measured shortly before and after a temperature-rise test and a subsequent cooling stage. Changes in TFs due to a change in oil temperature are found at frequencies higher than 400 kHz. Furthermore, the influence of the oil temperature on the repeatability of the measurements in FRA is objectively evaluated by employing a numerical index, which represents the identification degree of two compared TFs. It is found that the influence of the oil temperature is negligible when the average oil temperature is less than 50 degrees C.
引用
收藏
页码:472 / 480
页数:9
相关论文
共 50 条
  • [1] Effects of Test Cable Ground Extensions on Repeatability of Frequency Response Analysis Measurements on Power Transformers
    Reykherdt, Andrey A.
    Davydov, Valery G.
    IEEE ELECTRICAL INSULATION MAGAZINE, 2012, 28 (03) : 26 - 31
  • [2] Influence of Employing Different Measuring Systems on Measurement Repeatability in Frequency Response Analyses of Power Transformers
    Miyazaki, Satoru
    Mizutani, Yoshinobu
    Tahir, Mehran
    Tenbohlen, Stefan
    IEEE ELECTRICAL INSULATION MAGAZINE, 2019, 35 (02) : 27 - 33
  • [3] Influence of Moisture Content on the Frequency Response Analysis of Power Transformers
    Wang, Li
    Dong, Ming
    Xie, Jiacheng
    Hu, Yizhuo
    Ren, Ming
    2018 12TH INTERNATIONAL CONFERENCE ON THE PROPERTIES AND APPLICATIONS OF DIELECTRIC MATERIALS (ICPADM 2018), 2018, : 614 - 617
  • [4] A Contribution to the Analysis of Frequency Response and Impedance Measurements to Evaluation and Diagnostic of Power Transformers
    Martins, Helvio J. A.
    Urbani, Bruno
    Ferreira, Cintia de Faria
    ICHVE 2008: 2008 INTERNATIONAL CONFERENCE ON HIGH VOLTAGE ENGINEERING AND APPLICATION, 2008, : 566 - 569
  • [5] Precise Measurements of the Temperature Influence on the Complex Permittivity of Power Transformers Moistened Paper-Oil Insulation
    Zukowski, Pawel
    Rogalski, Przemyslaw
    Kierczynski, Konrad
    Koltunowicz, Tomasz N.
    ENERGIES, 2021, 14 (18)
  • [6] Core influence on the frequency response analysis (FRA) of power transformers through the finite element method
    Alvarez, D. L.
    Rosero, J. A.
    Mombello, E. E.
    INGENIERIA E INVESTIGACION, 2015, 35 : 110 - 117
  • [7] A NEW FREQUENCY-RESPONSE ANALYSIS METHOD FOR POWER TRANSFORMERS
    VAESSEN, PTM
    HANIQUE, E
    IEEE TRANSACTIONS ON POWER DELIVERY, 1992, 7 (01) : 384 - 391
  • [8] Frequency Response Analysis as a technique for moisture diagnostics of power transformers
    Yadav, Ramesh
    Venkatasami, A.
    PROCEEDINGS OF 2008 INTERNATIONAL CONFERENCE ON CONDITION MONITORING AND DIAGNOSIS, 2007, : 906 - 908
  • [9] Investigation of Core Effect on Frequency response Analysis of Power Transformers
    Mohseni, H.
    Mousavi, S. A.
    Mirzaie, H. R.
    Eslamian, M.
    Kharezi, M.
    Miralikhanie, S. K.
    2009 IEEE ELECTRICAL INSULATION CONFERENCE, 2009, : 124 - 128
  • [10] Interpretation of Frequency Response Analysis for Fault Detection in Power Transformers
    Al-Ameri, Salem Mgammal
    Kamarudin, Muhammad Saufi
    Yousof, Mohd Fairouz Mohd
    Salem, Ali A.
    Siada, A. Abu
    Mosaad, Mohamed I.
    APPLIED SCIENCES-BASEL, 2021, 11 (07):