Good repeatability of measurements of frequency response analysis (FRA) on power transformers can only be secured when selecting the same connection method of the used measuring leads as that employed in the measurement of reference data.
引用
收藏
页码:27 / 33
页数:7
相关论文
共 50 条
  • [1] Influence of Oil Temperature on Repeatability of Measurements in Frequency Response Analysis of Power Transformers
    Miyazaki, Satoru
    Mizutani, Yoshinobu
    Wada, Yoshihiro
    Hayashida, Chikara
    PROCEEDINGS OF THE 21ST INTERNATIONAL SYMPOSIUM ON HIGH VOLTAGE ENGINEERING, VOL 1, 2020, 598 : 472 - 480
  • [2] Influence of Moisture Content on the Frequency Response Analysis of Power Transformers
    Wang, Li
    Dong, Ming
    Xie, Jiacheng
    Hu, Yizhuo
    Ren, Ming
    2018 12TH INTERNATIONAL CONFERENCE ON THE PROPERTIES AND APPLICATIONS OF DIELECTRIC MATERIALS (ICPADM 2018), 2018, : 614 - 617
  • [3] Effects of Test Cable Ground Extensions on Repeatability of Frequency Response Analysis Measurements on Power Transformers
    Reykherdt, Andrey A.
    Davydov, Valery G.
    IEEE ELECTRICAL INSULATION MAGAZINE, 2012, 28 (03) : 26 - 31
  • [4] Frequency response of Measurement Current Transformers
    Cataliotti, A.
    Di Cara, D.
    Di Franco, P. A.
    Emanuel, A. E.
    Nuccio, S.
    2008 IEEE INSTRUMENTATION AND MEASUREMENT TECHNOLOGY CONFERENCE, VOLS 1-5, 2008, : 1254 - +
  • [5] Standard for Frequency Characteristics Measurement at Power Transformers
    Marinescu, A.
    Dumbrava, I.
    2011 7TH INTERNATIONAL SYMPOSIUM ON ADVANCED TOPICS IN ELECTRICAL ENGINEERING (ATEE), 2011,
  • [6] Experimental validation of using frequency response analysis method in measuring interwinding capacitance of power transformers
    Arumugam, Saravanakumar
    ENGINEERING REPORTS, 2019, 1 (05)
  • [7] Numerical Modelling of Piezoelectric Transformers for Low Frequency Measurement and Disturbance Monitoring in Power Systems
    Lele, Sneha
    Sobot, Robert
    Sidhu, Tarlochan
    2012 IEEE ELECTRICAL POWER AND ENERGY CONFERENCE (EPEC), 2012, : 188 - 191
  • [8] CALIBRATION OF TEST SYSTEMS FOR MEASURING POWER LOSSES OF TRANSFORMERS
    MEHTA, SP
    PETERSONS, O
    IEEE TRANSACTIONS ON POWER DELIVERY, 1986, 1 (04) : 215 - 223
  • [9] An Alternative Measurement Approach to Sweep Frequency Response Analysis (SFRA) for Power Transformers Fault Diagnosis
    Devadiga, Anurag A.
    Harid, Nouredine
    Griffiths, Huw
    Barkat, Braham
    2019 54TH INTERNATIONAL UNIVERSITIES POWER ENGINEERING CONFERENCE (UPEC), 2019,
  • [10] Identification of the most sensitive frequency response measurement technique for diagnosis of interturn faults in power transformers
    Behjat, V.
    Vahedi, A.
    Setayeshmehr, A.
    Borsi, H.
    Gockenbach, E.
    MEASUREMENT SCIENCE AND TECHNOLOGY, 2010, 21 (07)