The IFR online detector control at the BaBar experiment

被引:0
|
作者
Paolucci, P
Cavallo, N
Fabozzi, F
Piccolo, D
机构
[1] Stanford Linear Accelerator Ctr, Stanford, CA 94309 USA
[2] Ist Nazl Fis Nucl, Sezione Napoli, Complesso Monte Sant Angelo, I-80126 Naples, Italy
关键词
D O I
10.1109/23.846145
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
The Instrumented Flux Return (IFR)[I] is one of the five subdetectors of the BaBar[2] experiment on the PEP II accelerator at SLAG. The IFR consists of 774 Resistive Plate Chamber (RPC) detectors, covering an area of about 2,000 m(2) and equipped with 3,000 Front-end Electronic Cards (FEC) reading about 50,000 channels (readout strips). The first aim of a B-factory experiment is to run continuously without any interruption and then the Detector Control system plays a very important role in order to reduce the dead-time due to the hardware problems. The I.N.F.N. group of Naples has designed and built the IFR Online Detector Control system (IODC)[3] in order to control and monitor the operation of this large number of detectors and of all the IFR subsystems: High Voltage, Low Voltage, Gas system, Trigger and DAQ crates. The IODC consists of 8 custom DAQ stations, placed around the detector and one central DAQ station based on VME technology and placed in electronic house. The IODC use VxWorks and EPICS to implement slow control data flow of about 2500 hardware channels and to develop part of the readout module consisting in about 3500 records. EPICS is interfaced with the BaBar Run Control through the Component Proxy and with the BaBar database (Objectivity) through the Archiver and KeyLookup processes.
引用
收藏
页码:192 / 195
页数:4
相关论文
共 50 条
  • [1] IFR online detector control at the BaBar experiment
    Paolucci, P.
    Cavallo, N.
    Fabozzi, F.
    Piccolo, D.
    IEEE Transactions on Nuclear Science, 2000, 47 (2 I) : 192 - 195
  • [2] The IFR online detector control at the BaBar experiment at SLAC
    Paolucci, P
    Cavallo, N
    Fabozzi, F
    Piccolo, D
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2000, 456 (1-2): : 137 - 139
  • [3] Gas system upgrade for the BaBar IFR detector at SLAC
    Foulkes, S
    Gary, JW
    Shen, BC
    Wang, K
    Boyce, R
    Messner, R
    Stiles, P
    Sinev, N
    Band, HR
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2005, 538 (1-3): : 801 - 809
  • [4] A barrel IFR instrumented with limited streamer tubes for babar experiment
    Cibinetto, G
    INTERNATIONAL JOURNAL OF MODERN PHYSICS A, 2005, 20 (16): : 3834 - 3838
  • [5] Front-end readout development for the IFR muon detector at BaBar
    Cavallo, N
    Fabozzi, F
    Paolucci, P
    Parascandolo, L
    Parascandolo, P
    Piccolo, D
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1998, 409 (1-3): : 297 - 299
  • [6] The RPC-based IFR system at BaBar experiment: preliminary results
    Piccolo, D
    Palano, A
    Bagnasco, S
    Buzzo, A
    Contri, R
    Crosetti, G
    Lo Vetere, M
    Macri, M
    Monge, R
    Passaggio, S
    Patrignani, C
    Robutti, E
    Santroni, A
    Anulli, F
    Baldini, R
    Calcaterra, A
    De Sangro, R
    Falciai, D
    Finocchiaro, G
    Patteri, P
    Peruzzi, I
    Piccolo, M
    Yu, Z
    Zallo, A
    Cavallo, N
    De Nardo, G
    Fabozzi, F
    Gatto, C
    Lista, L
    Paolucci, P
    Sciacca, C
    Bionta, R
    Wright, D
    Band, H
    Johnson, J
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2002, 477 (1-3): : 435 - 439
  • [7] The detector control system for BaBaR
    Abrams, G
    Allison, S
    Anthony, P
    Kirkby, D
    Lewis, S
    Lionberger, C
    Meyer, T
    Morandin, M
    Olsen, J
    Paolucci, P
    Vasileiadis, G
    Zioulas, G
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2000, 47 (02) : 181 - 185
  • [8] Distributed Online Conditions Database of the BaBar Experiment
    Khan, A.
    Gaponenko, I. A.
    Brown, D. N.
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2008, 55 (05) : 2579 - 2583
  • [9] The BABAR detector
    Aubert, B
    Bazan, A
    Boucham, A
    Boutigny, D
    De Bonis, I
    Favier, J
    Gaillard, JM
    Jeremie, A
    Karyotakis, Y
    Le Flour, T
    Lees, JP
    Lieunard, S
    Petitpas, P
    Robbe, P
    Tisserand, V
    Zachariadou, K
    Palano, A
    Chen, GP
    Chen, JC
    Qi, ND
    Rong, G
    Wang, P
    Zhu, YS
    Eigen, G
    Reinertsen, PL
    Stugu, B
    Abbott, B
    Abrams, GS
    Amerman, L
    Borgland, AW
    Breon, AB
    Brown, DN
    Button-Shafer, J
    Clark, AR
    Dardin, S
    Day, C
    Dow, SF
    Fan, Q
    Gaponenko, I
    Gill, MS
    Goozen, FR
    Gowdy, SJ
    Gritsan, A
    Groysman, Y
    Hernikl, C
    Jacobsen, RG
    Jared, RC
    Kadel, RW
    Kadyk, J
    Karcher, A
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2002, 479 (01): : 1 - 116
  • [10] Resistive plate chamber performance in the BaBar IFR system
    Anulli, F
    Bagnasco, S
    Baldini, R
    Band, HR
    Bionta, R
    Brau, JE
    Brigljevic, V
    Buzzo, A
    Calcaterra, A
    Carpinelli, M
    Cartaro, T
    Cavallo, N
    Crosetti, G
    de Sangro, R
    De Nardo, G
    Eichenbaum, A
    Fabozzi, F
    Falciai, D
    Ferrarotto, F
    Ferroni, F
    Finocchiaro, G
    Forti, F
    Frey, R
    Gatto, C
    Grauges, E
    Iwasaki, M
    Johnson, JR
    Lange, DJ
    Lista, L
    Lo Vetere, M
    Lu, C
    Macri, M
    Messner, R
    Moore, TB
    Morganti, S
    Neri, N
    Neal, H
    Palano, A
    Paoloni, E
    Paolucci, P
    Passaggio, S
    Pastore, F
    Patteri, P
    Peruzzi, I
    Piccolo, M
    Piccolo, D
    Piredda, G
    Robutti, E
    Roodman, A
    Santroni, A
    2001 IEEE NUCLEAR SCIENCE SYMPOSIUM, CONFERENCE RECORDS, VOLS 1-4, 2002, : 519 - 524