SUSTAINABLE APPROACH TO ENERGY EFFICIENCY: MITIGATION OF INDOOR MICROCLIMATE AIR PARAMETERS IN A NATURALLY VENTILATED LIVESTOCK BUILDING

被引:0
|
作者
Denizopoulou, A. [1 ]
Andreopoulou, Z. [2 ,3 ]
Martzopoulou, A. [3 ]
Fragos, V [1 ]
机构
[1] Aristotle Univ Thessaloniki, Dept Hydraul Soil Sci & Agr Engn, Sch Agr, Thessaloniki 54124, Greece
[2] Aristotle Univ Thessaloniki, Sch Forestry & Nat Environm, P Box 247, Thessaloniki 54124, Greece
[3] Aristotle Univ Thessaloniki, Sch Architecture, Urban & Reg Innovat Res Unit, URENIO, Thessaloniki 54124, Greece
来源
关键词
indoor air quality; mitigation measures; livestock building; natural ventilation; open source device technology; AMMONIA; EMISSIONS;
D O I
暂无
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Indoor air pollution mitigation measures within a livestock building are crucial to farmer and bird health, livability of flock and animal productivity. Such measures are essential to minimise the accumulation of noxious gases that also affect the microclimate of the rural adjacent region. In the present study carbon dioxide and ammonia concentration, temperature and relative humidity were monitored in a naturally ventilated organic laying hen house in Northern Greece. Measurements were performed at one sampling point in the middle of the building by using open source device technology and compatible sensors for ammonia, temperature and humidity measurements and a carbon dioxide meter with a non-dispersive infrared CO2 sensor for carbon dioxide measurements during a 12-day period in spring. The main goal of this work was the evaluation of the contribution of natural ventilation in controlling indoor air quality parameters in the poultry house. Two different days were chosen one during which the side windows were closed for one hour and then re-opened and one when they remained open as usually done. Results identified the efficient function of the side openings and of the circular air vents along the ceiling of the structure indicating that the implementation of natural ventilation provides an adequate, sustainable and energy-efficient solution towards mitigating indoor air pollution.
引用
收藏
页码:562 / 570
页数:9
相关论文
共 39 条
  • [31] Effects of Supply Parameters of Stratum Ventilation on Energy Utilization Efficiency and Indoor Thermal Comfort: A Computational Approach
    Zhang, Lina
    Mao, Yanhui
    Tu, Qiu
    Wu, Xiaogang
    Tan, Lingyu
    MATHEMATICAL PROBLEMS IN ENGINEERING, 2021, 2021
  • [32] Indoor Lighting Conversion Approach for Sustainable Energy Efficiency Applications in Campus Buildings: Hitit University Engineering Faculty Study
    Seyitoglu, Sertac Samed
    Tozlu, Omer Faruk
    Avcioglu, Emir
    GAZI UNIVERSITY JOURNAL OF SCIENCE, 2023, 36 (03): : 1326 - 1337
  • [33] Indoor air environment and night cooling energy efficiency of a southern German passive public school building operated by the heat recovery air conditioning unit
    Wang, Yang
    Zhao, Fu-Yun
    Kuckelkorn, Jens
    Li, Xiao-Hong
    Wang, Han-Qing
    ENERGY AND BUILDINGS, 2014, 81 : 9 - 17
  • [34] Discussion on Indoor Design Parameters of Air-Conditioning in the Large Space Building with Considering Comfort and Energy Consumption Based on Nomograms
    Huang, Chen
    Cai, Ning
    Shen, Li
    PROCEEDINGS OF THE 8TH INTERNATIONAL SYMPOSIUM ON HEATING, VENTILATION AND AIR CONDITIONING, VOL 1: INDOOR AND OUTDOOR ENVIRONMENT, 2014, 261 : 185 - 192
  • [35] Carbon, indoor air, energy and financial benefits of coupled ventilation upgrade and enhanced rooftop garden installation: An interdisciplinary climate mitigation approach
    Buckley, Sarabeth
    Connolly, Catherine L.
    Templer, Pamela H.
    Ashmore, Jacqueline
    Carvalho, Luis
    Phillips, Nathan
    Fabian, Patricia
    SUSTAINABLE CITIES AND SOCIETY, 2023, 97
  • [36] Sustainable building energy efficiency retrofit for hotel buildings using EPC mechanism in China: analytic Network Process (ANP) approach
    Xu, Pengpeng
    Chan, Edwin H. W.
    Visscher, Henk J.
    Zhang, Xiaoling
    Wu, Zezhou
    JOURNAL OF CLEANER PRODUCTION, 2015, 107 : 378 - 388
  • [37] Occupancy-based zone-level VAV system control implications on thermal comfort, ventilation, indoor air quality and building energy efficiency
    Anand, Prashant
    Sekhar, Chandra
    Cheong, David
    Santamouris, Mattheos
    Kondepudi, Sekhar
    ENERGY AND BUILDINGS, 2019, 204
  • [38] Building energy efficiency and thermal comfort in tropical climates - Presentation of a numerical approach for predicting the percentage of well-ventilated living spaces in buildings using natural ventilation
    Bastide, Alain
    Lauret, Philippe
    Garde, Francois
    Boyer, Harry
    ENERGY AND BUILDINGS, 2006, 38 (09) : 1093 - 1103
  • [39] Analysis of UK domestic building retrofit scenarios based on the E.ON Retrofit Research House using energetic hygrothermics simulation - Energy efficiency, indoor air quality, occupant comfort, and mould growth potential
    Hall, Matthew R.
    Casey, Sean P.
    Loveday, Dennis L.
    Gillott, Mark
    BUILDING AND ENVIRONMENT, 2013, 70 : 48 - 59