The effect of imprecise repositioning on lesion volume measurements in patients with multiple sclerosis

被引:42
|
作者
Filippi, M
Marciano, N
Capra, R
Rocca, MA
Prandini, F
Gasparotti, R
Horsfield, MA
Comi, G
机构
[1] UNIV BRESCIA,SPEDALI CIVILI,DEPT NEURORADIOL,BRESCIA,ITALY
[2] UNIV BRESCIA,SPEDALI CIVILI,DEPT NEUROL,BRESCIA,ITALY
[3] POLIAMBULANZA,DEPT NEUROSCI,BRESCIA,ITALY
[4] UNIV LEICESTER,DIV MED PHYS,LEICESTER,LEICS,ENGLAND
关键词
D O I
10.1212/WNL.49.1.274
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
In this study, we evaluated the effect of imprecision in patient repositioning encountered in real life on multiple sclerosis (MS) lesion volumes measured from MRIs. We also evaluated two putative methods for reducing the variability in these lesion volume measurements: first, a reduction of slice thickness (from the conventional 5 mm to 3 mm) and second, the application of a new repositioning technique based on the use of head immobilization shells. We evaluated the errors in lesion volume by scanning 10 patients a total of four times using the two slice thicknesses and two repositioning methods (conventional and using a head immobilization shell). The mean absolute percentage difference between two corresponding scans was 6.8% (range, 1.24 to 11%) using conventional slice thickness and repositioning, 4.1% (range, 0.7 to 5.56%) using conventional slice thickness and head immobilization shells, 2.6% (range, 0.8 to 6.66%) using the conventional repositioning technique and 3-mm slice thickness, and 1.4% (range, 0.2 to 6.14%) using slice thickness of 3 mm and head immobilization shells. These mean absolute differences were significantly different (p = 0.0008). Our results indicate that the effect of repositioning errors of the order of those that can be encountered in the daily life situation of clinical trials affects significantly lesion load measurements in MS and that the combined use of thinner slices and more accurate repositioning techniques can markedly improve the reproducibility of such measurements.
引用
收藏
页码:274 / 276
页数:3
相关论文
共 50 条
  • [31] Posterior fossa lesion volume and slowed information processing in multiple sclerosis
    Archibald, CJ
    Wei, XC
    Scott, JN
    Wallace, CJ
    Zhang, Y
    Metz, LM
    Mitchell, JR
    BRAIN, 2004, 127 : 1526 - 1534
  • [32] Atrophied Brain Lesion Volume: A New Imaging Biomarker in Multiple Sclerosis
    Dwyer, Michael G.
    Bergsland, Niels
    Ramasamy, Deepa P.
    Jakimovski, Dejan
    Weinstock-Guttman, Bianca
    Zivadinov, Robert
    JOURNAL OF NEUROIMAGING, 2018, 28 (05) : 490 - 495
  • [33] Automatic quantification of multiple sclerosis lesion volume using stereotaxic space
    Zijdenbos, A
    Evans, A
    Riahi, F
    Sled, J
    Chui, J
    Kollokian, V
    VISUALIZATION IN BIOMEDICAL COMPUTING, 1996, 1131 : 439 - 448
  • [34] Atrophied T2 Lesion Volume in Multiple Sclerosis: Reducing the Focus on Lesion Counting
    Chiang, Gloria C.
    RADIOLOGY, 2019, 293 (02) : 434 - 435
  • [35] Salient Central Lesion Volume: A Standardized Novel Fully Automated Proxy for Brain FLAIR Lesion Volume in Multiple Sclerosis
    Dwyer, Michael G.
    Bergsland, Niels
    Ramasamy, Deepa P.
    Weinstock-Guttman, Bianca
    Barnett, Michael H.
    Wang, Chenyu
    Tomic, Davorka
    Silva, Diego
    Zivadinov, Robert
    JOURNAL OF NEUROIMAGING, 2019, 29 (05) : 615 - 623
  • [36] Grey matter volume determination in clinically isolated syndromes and patients with multiple sclerosis: role of lesion masking
    Pareto, D.
    Aymerich, F. X.
    Alonso, J.
    Huerga, E.
    Sastre-Garriga, J.
    Montalban, X.
    Rovira, A.
    MULTIPLE SCLEROSIS JOURNAL, 2011, 17 : S162 - S162
  • [37] Cognitive impairment in patients with relapsing-remitting multiple sclerosis. The correlation with MRI lesion volume
    Karlinska, Iwona
    Siger, Malgorzata
    Lewanska, Magdalena
    Selmaj, Krzysztof
    NEUROLOGIA I NEUROCHIRURGIA POLSKA, 2008, 42 (05) : 416 - 423
  • [38] Spinal cord volume in multiple sclerosis patients with dissociation of disability and intracranial white matter lesion load
    Andelova, M.
    Krasensky, J.
    Uher, T.
    Kusova, E.
    Benova, B.
    Kucerova, K.
    Kadrnozkova, L.
    Motyl, J.
    Havrdova, E. Kubala
    Vaneckova, M.
    Horakova, D.
    MULTIPLE SCLEROSIS JOURNAL, 2018, 24 : 211 - 211
  • [39] Intra- and inter-observer agreement of brain MRI lesion volume measurements in multiple sclerosis - A comparison of techniques
    Filippi, M
    Horsfield, MA
    Bressi, S
    Martinelli, V
    Baratti, C
    Reganati, P
    Campi, A
    Miller, DH
    Comi, G
    BRAIN, 1995, 118 : 1593 - 1600
  • [40] INTRA-RATER AND INTERRATER AGREEMENT OF BRAIN MRI LESION VOLUME MEASUREMENTS IN MULTIPLE-SCLEROSIS - A COMPARISON OF TECHNIQUES
    FILIPPI, M
    HORSFIELD, M
    BARATTI, C
    REGANATI, P
    BRESSI, S
    MARTINELLI, V
    MILLER, D
    COMI, G
    NEUROLOGY, 1995, 45 (04) : A399 - A399