Intercomparison study of the size-dependent counting efficiency of 26 condensation particle counters

被引:122
|
作者
Wiedensohlet, A
Orsini, D
Covert, DS
Coffmann, D
Cantrell, W
Havlicek, M
Brechtel, FJ
Russell, LM
Weber, RJ
Gras, J
Hudson, JG
Litchy, M
机构
[1] UNIV WASHINGTON,DEPT ATMOSPHER SCI,SEATTLE,WA 98195
[2] UNIV ALASKA,INST GEOPHYS,FAIRBANKS,AK 99775
[3] TSI INC,ST PAUL,MN 55164
[4] COLORADO STATE UNIV,DEPT ATMOSPHER SCI,FT COLLINS,CO 80523
[5] CALTECH,DEPT CHEM ENGN,PASADENA,CA 91125
[6] UNIV MINNESOTA,DEPT MECH ENGN,MINNEAPOLIS,MN 55455
[7] CSIRO,DIV ATMOSPHER RES,MORDIALLOC,VIC 3195,AUSTRALIA
[8] UNIV NEVADA,DESERT RES INST,RENO,NV 89506
[9] UNIV HAWAII,DEPT OCEANOG,HONOLULU,HI 96822
基金
美国国家科学基金会;
关键词
D O I
10.1080/02786829708965469
中图分类号
TQ [化学工业];
学科分类号
0817 ;
摘要
Particle detection efficiency curves for 26 condensation particle counters were determined during a calibration workshop in preparation for the Aerosol Characterization Experiment 1 (ACE1). Three different types of commercially available particle counters, the ultrafine condensation particle counter (TSI-3025) and the condensation particle counters (TSI-3010 and TSI-3760 or TSI-7610) were investigated at default temperature and flow settings as well as for other flow rates and temperature differences between the saturator and the condenser. Furthermore, the pulse-height-analysis ultrafine condensation particle counter and a TSI-3010 modified to achieve a higher temperature difference were calibrated. In this study, the large number of particle counters investigated provided the opportunity to obtain a more statistically significant picture of the performance of different particle counters for different operating conditions. (C) 1997 American Association for Aerosol Research.
引用
收藏
页码:224 / 242
页数:19
相关论文
共 50 条
  • [21] Particle Size-Dependent Electrophoresis in Polymer Solutions
    Bentor, Joseph
    Xuan, Xiangchun
    ANALYTICAL CHEMISTRY, 2024, 96 (07) : 3186 - 3191
  • [22] A study of size-dependent microindentation
    Chen, SH
    Tao, CJ
    Wang, TC
    ACTA MECHANICA, 2004, 167 (1-2) : 57 - 71
  • [23] Intercomparison in the laboratory of various Condensation Particle Counters challenged by nanoaerosols in the range 6-460 nm
    Bau, Sebastien
    Payet, Raphael
    Tritscher, Torsten
    Witschger, Olivier
    6TH NANOSAFE INTERNATIONAL CONFERENCE, 2019, 1323
  • [24] A study of size-dependent microindentation
    S. H. Chen
    C. J. Tao
    T. C. Wang
    Acta Mechanica, 2004, 167 : 57 - 71
  • [25] Size resolution and capillary centering in sheathed condensation particle counters studied with a new variable saturation condensation particle sizer
    de la Mora, Juan Fernandez
    Kozlowski, Jerzy
    Attoui, Michel
    Perez-Lorenzo, Luis J.
    Carbone, Francesco
    JOURNAL OF AEROSOL SCIENCE, 2025, 185
  • [26] The size-dependent morphology of Pd nanoclusters formed by gas condensation
    Pearmain, D.
    Park, S. J.
    Abdela, A.
    Palmer, R. E.
    Li, Z. Y.
    NANOSCALE, 2015, 7 (46) : 19647 - 19652
  • [27] REMARKS ABOUT SMALLEST PARTICLE-SIZE DETECTABLE IN CONDENSATION NUCLEI COUNTERS
    WALTER, H
    JAENICKE, R
    ATMOSPHERIC ENVIRONMENT, 1973, 7 (10) : 939 - 944
  • [28] Laboratory study of the performances of two individual Condensation Particle Counters
    Bau, Sebastien
    Payet, Raphael
    7TH NANOSAFE INTERNATIONAL CONFERENCE ON HEALTH AND SAFETY ISSUES RELATED TO NANOMATERIALS FOR A SOCIALLY RESPONSIBLE APPROACH, NANOSAFE 2020, 2021, 1953
  • [29] Particle size-dependent concentrations of polycyclic aromatic hydrocarbons
    Schnelle, J
    Wolf, K
    Frank, G
    Hietel, B
    Gebefugi, I
    Kettrup, A
    ANALYST, 1996, 121 (09) : 1301 - 1304
  • [30] No size-dependent net particle retention in the hindgut of horses
    Schwarm, Angela
    Clauss, Marcus
    Ortmann, Sylvia
    Jensen, Rasmus B.
    JOURNAL OF ANIMAL PHYSIOLOGY AND ANIMAL NUTRITION, 2022, 106 (06) : 1356 - 1363