Optimization of a flow injection analysis system for tartaric acid determination in wines

被引:21
|
作者
Silva, HADFO [1 ]
Alvares-Ribeiro, LMBC [1 ]
机构
[1] Univ Porto, LAQUIPAI, Fac Ciencias, P-4169007 Oporto, Portugal
关键词
flow injection analysis; wine; tartaric acid; dialysis; simplex optimisation;
D O I
10.1016/S0039-9140(02)00436-8
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The objective of this work is the development and optimization of a method for tartaric acid analysis in wines that does not require any sample pre-treatment and with adequate accuracy. A flow injection analysis manifold with three channels, using a dialysis unit to eliminate sample matrix interferences and to accomplish on-line dilution, is proposed for the spectrophotometrical determination of tartaric acid in wines making use of its reaction with vanadate. The proposed method is fast, accurate, simple, economic and does not require any sample pre-treatment. Preliminary studies using factorial designs were performed to determine which operational parameters should be included in the optimization stage. The optimization was performed using a modified simplex algorithm with a response function that included sensitivity, deviation from linearity at low concentrations and residence time, used as an inverse measure of sampling rate. The most relevant analytical parameters of the method are presented, including a comparison between the results provided by the proposed method and by an alternative procedure in the analysis of a set of wine samples from Portugal, with tartaric acid values in the range 0.5-4 g l(-1). (C) 2002 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:1311 / 1318
页数:8
相关论文
共 50 条
  • [31] Determination of pipernidic acid by flow injection analysis with chemiluminescence detection
    Li, LQ
    Wu, YY
    Feng, ML
    Lü, JR
    CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2002, 30 (02) : 169 - 171
  • [32] Determination of uric acid by chemiluminescence-flow injection analysis
    Wu, YY
    Li, LQ
    Geng, Z
    Liu, QG
    CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 1999, 27 (05) : 543 - 546
  • [33] Chemiluminescence determination of folic acid by a flow injection analysis assembly
    Wabaidur, Saikh Mohammad
    Alam, Seikh Mafiz
    Lee, Sang Hak
    Alothman, Zeid Abdullah
    Eldesoky, Gaber E.
    SPECTROCHIMICA ACTA PART A-MOLECULAR AND BIOMOLECULAR SPECTROSCOPY, 2013, 105 : 412 - 417
  • [34] Flow Injection Analysis Determination of Ascorbic Acid with Spectrofluorimetric Detection
    Ensafi, A. A.
    Rezaei, B.
    Analytical Letters, 31 (02):
  • [35] Flow injection analysis determination of ascorbic acid with spectrofluorimetric detection
    Ensafi, AA
    Rezaei, B
    ANALYTICAL LETTERS, 1998, 31 (02) : 333 - 342
  • [36] Sequential injection system for the spectrophotometric determination of reducing sugars in wines
    Araújo, AN
    Lima, JLFC
    Rangel, AOSS
    Segundo, MA
    TALANTA, 2000, 52 (01) : 59 - 66
  • [37] CONDUCTIMETRIC AND SPECTROPHOTOMETRIC DETERMINATION OF THE VOLATILE ACIDITY OF WINES BY FLOW-INJECTION
    BARROS, FG
    TUBINO, M
    ANALYST, 1992, 117 (05) : 917 - 919
  • [38] Spectrophotometric determination of carbon dioxide and sulphur dioxide in wines by flow injection
    Atanassov, G
    Lima, RC
    Mesquita, RBR
    Rangel, AOSS
    Tóth, IV
    ANALUSIS, 2000, 28 (01) : 77 - 82
  • [39] Semiautomatic flow-injection method for determination of volatile acidity in wines
    González-Rodríguez, J
    Pérez-Juan, PP
    de Castro, MDL
    JOURNAL OF AOAC INTERNATIONAL, 2001, 84 (06) : 1846 - 1850
  • [40] Automatic spectrophotometric procedure for the determination of tartaric acid in wine employing multicommutation flow analysis process
    Fernandes, EN
    Reis, BF
    ANALYTICA CHIMICA ACTA, 2006, 557 (1-2) : 380 - 386