Noninvasive Continuous Blood Pressure Measurement with Wearable Millimeter Wave Device

被引:9
|
作者
Liao, Catherine [1 ]
Shay, Oliver [1 ]
Gomes, Elizabeth [1 ]
Bikhchandani, Nikhil [1 ]
机构
[1] Blumio Inc, San Mateo, CA 94401 USA
关键词
blood pressure; continuous noninvasive blood pressure monitoring; CNIBP; FMCW radar; medical device; millimeter wave radar; vital sign detection; AGREEMENT; BLAND;
D O I
10.1109/BSN51625.2021.9507020
中图分类号
TB3 [工程材料学]; R318.08 [生物材料学];
学科分类号
0805 ; 080501 ; 080502 ;
摘要
Wearable monitors for measuring vital signs such as blood pressure will greatly impact the medical field. This work presents a millimeter-wave, radar-based system for performing accurate measurements of systolic and diastolic blood pressure at the radial artet-y. A 120-subject study was conducted to assess the feasibility of the proposed approach. Blood pressure was determined using a one-time initialization process that converts radar output into pressure units (in mmHg). Measured systolic and diastolic blood pressure values against a clinical reference device show promise for beat-to -beat blood pressure measurement in a variety of healthcare settings.
引用
收藏
页数:5
相关论文
共 50 条
  • [31] Noninvasive Continuous Blood Pressure Measurement and GPS Position Monitoring of Patients
    Krejcar, Ondrej
    Slanina, Zdenek
    Stambachr, Jan
    Silber, Petr
    Frischer, Robert
    2009 IEEE 70TH VEHICULAR TECHNOLOGY CONFERENCE FALL, VOLS 1-4, 2009, : 3 - +
  • [32] NONINVASIVE CONTINUOUS BLOOD-PRESSURE MEASUREMENT FROM THE FINGER - FACTORS AFFECTING THE MEASUREMENT
    KURKI, TS
    SMITH, NT
    HEAD, N
    DECSILVER, H
    QUINN, A
    ANESTHESIOLOGY, 1986, 65 (3A) : A134 - A134
  • [33] Subjective perceptions of a new, noninvasive, semi-continuous blood pressure device
    Weaver, JB
    Christie, IC
    Friedman, BH
    Sargent, SL
    PSYCHOSOMATIC MEDICINE, 2001, 63 (01): : 157 - 157
  • [34] ACCURACY OF CONTINUOUS NONINVASIVE BLOOD-PRESSURE MEASUREMENT AT HIGH AND LOW BLOOD PRESSURES
    WONG, DH
    EATON, S
    CLACK, S
    ZACCARI, J
    SURESH, K
    BOGARD, D
    WATSON, TB
    ANESTHESIA AND ANALGESIA, 1994, 78 (02): : U257 - U257
  • [35] Noninvasive continuous blood pressure monitoring
    Poghosyan, Armen
    Mouradian, Vahram
    Hovhannisyan, Levon
    OPTICAL FIBERS AND SENSORS FOR MEDICAL DIAGNOSTICS AND TREATMENT APPLICATIONS XV, 2015, 9317
  • [36] Modeling of the cuffless blood pressure measurement errors for the evaluation of a wearable medical device
    Xiang, X. Y.
    Poon, Carmen C. Y.
    Zhang, Yuan-ting
    2006 3RD IEEE/EMBS INTERNATIONAL SUMMER SCHOOL ON MEDICAL DEVICES AND BIOSENSORS, 2006, : 105 - +
  • [37] An Armband Wearable Device for Overnight and Cuff-Less Blood Pressure Measurement
    Zheng, Ya-Li
    Yan, Bryan P.
    Zhang, Yuan-Ting
    Poon, Carmen C. Y.
    IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2014, 61 (07) : 2179 - 2186
  • [38] Noninvasive Continuous Blood Pressure Monitoring Based on Wearable Radar Sensor with Preliminary Clinical Validation
    Wen, Li
    Dong, Shuqin
    Zhang, Zhi
    Gu, Changzhan
    Mao, Junfa
    2022 IEEE/MTT-S INTERNATIONAL MICROWAVE SYMPOSIUM (IMS 2022), 2022, : 707 - 710
  • [39] NONINVASIVE CONTINUOUS BLOOD PRESSURE MONITORING BASED ON WEARABLE RADAR SENSOR WITH PRELIMINARY CLINICAL VALIDATION
    Liu, Jiaqi
    Wen, Li
    Dong, Shuqin
    Zhang, Zhi
    Gu, Changzhan
    Mao, Junfa
    JOURNAL OF HYPERTENSION, 2023, 41 : E291 - E292
  • [40] Single-Channel Bioimpedance Measurement for Wearable Continuous Blood Pressure Monitoring
    Wang, Ting-Wei
    Chen, Wen-Xiang
    Chu, Hsiao-Wei
    Lin, Shien-Fong
    IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2021, 70