Duplex ultrasound follow-up after fenestrated and branched endovascular aneurysm repair (FEVAR and BEVAR)

被引:11
|
作者
Zierler, R. Eugene [1 ,2 ,3 ]
机构
[1] Univ Washington, Dept Surg, Sch Med, Box 356410, Seattle, WA 98195 USA
[2] Univ Washington, Med Ctr, DE Strandness Jr Vasc Lab, Seattle, WA 98195 USA
[3] Harborview Med Ctr, Seattle, WA USA
关键词
SURGERY PRACTICE GUIDELINES; SUPERIOR MESENTERIC-ARTERY; SOCIETY;
D O I
10.1053/j.semvascsurg.2020.05.006
中图分类号
R61 [外科手术学];
学科分类号
摘要
Endovascular aneurysm repair (EVAR) is now the predominant method for treatment of infrarenal abdominal aortic aneurysms. Although EVAR has numerous advantages over standard open surgical repair, it also exposes patients to risks such as aneurysm sac enlargement, endoleaks, and graft migration, which make surveillance or follow-up mandatory. Fenestrated (FEVAR) and branched (BEVAR) endografts have extended the application of EVAR to juxtarenal, pararenal/paravisceral, and thoracoabdominal aneurysms, with some complex aneurysms requiring combined approaches (F-BEVAR). Duplex ultrasound has been recommended as an alternative to frequent computed tomography imaging for EVAR follow-up when it can provide the clinically necessary information. The major components of a post-EVAR duplex examination include measurement of aortic aneurysm sac size, assessment for endoleak, and evaluation of the endograft for patency and integrity. The duplex protocol for EVAR follow-up can be extended for follow-up after FEVAR, BEVAR, and F-BEVAR, with additional attention to the device components associated with fenestrations and branches. At the University of Washington, the physician- modified endovascular graft approach has been used for FEVAR. During these procedures, covered stents are placed in the renal arteries through fenestrations and the superior mesenteric artery is perfused through a fenestration, but typically remains unstented. Duplex scanning of the renal and mesenteric arteries has been performed preoperatively and at 30 days, 6 months, 1 year, and annually. In a review of patients having covered stents placed in non-stenotic renal arteries during FEVAR, both peak systolic velocity and the renal to aortic velocity ratio remained below the standard significant stenosis threshold in most patients. The duplex velocity criteria for stenosis in native renal arteries appeared to overestimate the severity of stenosis in renal artery covered stents. The unstented superior mesenteric artery remained widely patent in the presence of fenestrations or crossing struts and was not associated with endoleaks. Duplex ultrasound protocols for follow-up after FEVAR, BEVAR, and F-BEVAR can be based on those that have been established for standard EVAR, along with assessment of fenestrations and branches, as well as patency of the renal and mesenteric arteries. (C) 2020 Elsevier Inc. All rights reserved.
引用
收藏
页码:60 / 64
页数:5
相关论文
共 50 条
  • [21] Factors Influencing Compliance to Follow-Up After Endovascular Aneurysm Repair
    Oezdemir-van Brunschot, Denise
    Zerellari, Romina
    Tevs, Maria
    Holzhey, David
    Botsios, Spiridon
    VASCULAR AND ENDOVASCULAR SURGERY, 2023, 57 (08) : 878 - 883
  • [22] Follow-up Surveillance After Endovascular Aneurysm Repair Less Is More?
    Hoel, Andrew W.
    Schanzer, Andres
    JAMA SURGERY, 2015, 150 (10) : 964 - 964
  • [23] Factors Predicting Noncompliance with Follow-up after Endovascular Aneurysm Repair
    Shiraev, Timothy P.
    Durur, Elif
    Robinson, David A.
    ANNALS OF VASCULAR SURGERY, 2018, 52 : 30 - 35
  • [24] Duplex Ultrasound Is a Clinically Useful Modality for Surveillance of Renal Branch Grafts After Fenestrated Endovascular Aneurysm Repair
    Tran, Kenneth
    Mcfarland, Graeme
    Sgroi, Michael
    Lee, Jason T.
    JOURNAL OF VASCULAR SURGERY, 2018, 68 (03) : E36 - E36
  • [25] Postdissection aortic aneurysm sac enlargement after fenestrated and branched endovascular aortic aneurysm repair
    Figueroa, Andres V.
    Tanenbaum, Mira T.
    Timaran, Carlos H.
    Oderich, Gustavo S.
    Eagleton, Matthew J.
    Schanzer, Andres
    Farber, Mark A.
    Beck, Adam W.
    Schneider, Darren B.
    Gasper, Warren
    Sweet, Matthew P.
    Lee, Anthony
    Cantor, Ryan S.
    Li, Xingsheng
    JOURNAL OF VASCULAR SURGERY, 2024, 80 (03)
  • [26] Outcomes of Explants vs Fenestrated-Branched Endovascular Aortic Aneurysm Repair After Failed Endovascular Aortic Aneurysm Repair
    Dias, Agenor
    Steenberge, Sean
    Farivar, Behzad S.
    Brier, Corey S.
    Kuramochi, Yuki
    Lyden, Sean P.
    Eagleton, Matthew J.
    JOURNAL OF VASCULAR SURGERY, 2017, 65 (06) : 44S - 45S
  • [27] Robot-assisted Fenestrated Endovascular Aneurysm Repair (FEVAR) Using the Magellan System
    Riga, Celia V.
    Bicknell, Colin D.
    Rolls, Alexander
    Cheshire, Nicholas J.
    Hamady, Mohamad S.
    JOURNAL OF VASCULAR AND INTERVENTIONAL RADIOLOGY, 2013, 24 (02) : 191 - 196
  • [28] Role of Contrast-Enhanced Ultrasound in the Follow-Up after Endovascular Abdominal Aortic Aneurysm Repair
    Benedetto, Filippo
    Spinelli, Domenico
    La Corte, Francesco
    Pipito, Narayana
    Passari, Gabriele
    De Caridi, Giovanni
    DIAGNOSTICS, 2022, 12 (12)
  • [29] Contrast enhanced duplex ultrasound for early postoperative follow-up after endovascular aneurysm repair: Relation to patient's initial risk of complications
    Park, Young Jun
    Mok, Sang Kyun
    Kim, Jang Yong
    Park, Sun Cheol
    Yun, Sang Seob
    VASCULAR, 2023, 31 (04) : 637 - 643
  • [30] Fenestrated and Branched Endovascular Aortic Aneurysm Repair Among Octogenarians
    Timaran, Carlos H.
    Tulip, Hans
    Timaran, David E.
    Baig, Shadman M.
    Valentine, R. James
    Gomez, Luis
    JOURNAL OF VASCULAR SURGERY, 2013, 57 (01) : 294 - 295