Diagnostic accuracy of 18F amyloid PET tracers for the diagnosis of Alzheimer's disease: a systematic review and meta-analysis

被引:177
|
作者
Morris, Elizabeth [1 ,2 ]
Chalkidou, Anastasia [1 ,2 ]
Hammers, Alexander [2 ]
Peacock, Janet [1 ,3 ,4 ]
Summers, Jennifer [1 ,3 ,4 ]
Keevil, Stephen [1 ,2 ,5 ]
机构
[1] Kings Coll London, St Thomas Hosp, Kings Technol Evaluat Ctr, London SE1 7EH, England
[2] Kings Coll London, Div Imaging Sci & Biomed Engn, Dept Biomed Engn, St Thomas Hosp, London SE1 7EH, England
[3] Kings Coll London, Div Hlth & Social Care Res, London SE1 7EH, England
[4] Kings Coll London, Guys & St Thomas NHS Fdn Trust, NIHR Biomed Res Ctr, London SE1 7EH, England
[5] St Thomas Hosp, Dept Med Phys, Guys & St Thomas NHS Fdn Trust, London, England
关键词
Florbetapir; Florbetaben; Flutemetamol; Amyloid; PET; Alzheimer's disease; MILD COGNITIVE IMPAIRMENT; TASK-FORCE; FLORBETAPIR; DEMENTIA; CRITERIA; RECOMMENDATIONS; AUTOPSY; PLAQUES; BINDING;
D O I
10.1007/s00259-015-3228-x
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Imaging or tissue biomarker evidence has been introduced into the core diagnostic pathway for Alzheimer's disease (AD). PET using F-18-labelled beta-amyloid PET tracers has shown promise for the early diagnosis of AD. However, most studies included only small numbers of participants and no consensus has been reached as to which radiotracer has the highest diagnostic accuracy. First, we performed a systematic review of the literature published between 1990 and 2014 for studies exploring the diagnostic accuracy of florbetaben, florbetapir and flutemetamol in AD. The included studies were analysed using the QUADAS assessment of methodological quality. A meta-analysis of the sensitivity and specificity reported within each study was performed. Pooled values were calculated for each radiotracer and for visual or quantitative analysis by population included. The systematic review identified nine studies eligible for inclusion. There were limited variations in the methods between studies reporting the same radiotracer. The meta-analysis results showed that pooled sensitivity and specificity values were in general high for all tracers. This was confirmed by calculating likelihood ratios. A patient with a positive ratio is much more likely to have AD than a patient with a negative ratio, and vice versa. However, specificity was higher when only patients with AD were compared with healthy controls. This systematic review and meta-analysis found no marked differences in the diagnostic accuracy of the three beta-amyloid radiotracers. All tracers perform better when used to discriminate between patients with AD and healthy controls. The sensitivity and specificity for quantitative and visual analysis are comparable to those of other imaging or biomarker techniques used to diagnose AD. Further research is required to identify the combination of tests that provides the highest sensitivity and specificity, and to identify the most suitable position for the tracer in the clinical pathway.
引用
收藏
页码:374 / 385
页数:12
相关论文
共 50 条
  • [21] [18F]-FDG PET in anal canal cancer: a systematic review and meta-analysis
    Mirshahvalad, Seyed Ali
    Mesci, Aruz
    Murad, Vanessa
    Kohan, Andres
    Ortega, Claudia
    Veit-Haibach, Patrick
    Metser, Ur
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2023, 51 (01) : 258 - 277
  • [22] [18F]-FDG PET in anal canal cancer: a systematic review and meta-analysis
    Seyed Ali Mirshahvalad
    Aruz Mesci
    Vanessa Murad
    Andres Kohan
    Claudia Ortega
    Patrick Veit-Haibach
    Ur Metser
    European Journal of Nuclear Medicine and Molecular Imaging, 2023, 51 : 258 - 277
  • [23] 18F-barbiturates are PET tracers with diagnostic potential in Alzheimer's disease
    Calamai, Elisa
    Dall'Angelo, Sergio
    Koss, David
    Domarkas, Juozas
    McCarthy, Timothy J.
    Mingarelli, Marco
    Riedel, Gernot
    Schweiger, Lutz F.
    Welch, Andy
    Platt, Bettina
    Zanda, Matteo
    CHEMICAL COMMUNICATIONS, 2013, 49 (08) : 792 - 794
  • [24] [18F]FDG PET/CT versus [18F]FDG PET/MRI in the diagnosis of lymph node metastasis in nasopharyngeal carcinoma: a systematic review and meta-analysis
    Lei, Junfang
    Li, Xu
    Xue, Wenbo
    Qian, Xinrui
    Wang, Tong
    Xiang, Yunuo
    Zhang, Yangchun
    Chen, Meixing
    Liu, Zhaohui
    FRONTIERS IN MEDICINE, 2024, 11
  • [25] Diagnostic accuracy of 18F-FDG PET or PET/CT for the characterization of adrenal masses: a systematic review and meta-analysis
    Kim, Seong-Jang
    Lee, Sang-Woo
    Pak, Kyoungjune
    Kim, In-Ju
    Kim, Keunyoung
    BRITISH JOURNAL OF RADIOLOGY, 2018, 91 (1086):
  • [26] Diagnostic and grading accuracy of 18F-FDOPA PET and PET/CT in patients with gliomas: a systematic review and meta-analysis
    Jiarui Xiao
    Yizi Jin
    Ji Nie
    Fukun Chen
    Xuelei Ma
    BMC Cancer, 19
  • [27] Diagnostic and grading accuracy of 18F-FDOPA PET and PET/CT in patients with gliomas: a systematic review and meta-analysis
    Xiao, Jiarui
    Jin, Yizi
    Nie, Ji
    Chen, Fukun
    Ma, Xuelei
    BMC CANCER, 2019, 19 (01)
  • [28] The potential diagnostic accuracy of urine formaldehyde levels in Alzheimer's disease: A systematic review and meta-analysis
    Chen, Fan
    Wang, Na
    Tian, Xinyan
    Qin, Yan
    Su, Juan
    He, Rongqiao
    He, Xiaping
    FRONTIERS IN AGING NEUROSCIENCE, 2022, 14
  • [29] Diagnostic Accuracy of 18F-FDG-PET and PET/CT in the Differential Diagnosis between Malignant and Benign Pleural Lesions: A Systematic Review and Meta-Analysis
    Treglia, Giorgio
    Sadeghi, Ramin
    Annunziata, Salvatore
    Lococo, Filippo
    Cafarotti, Stefano
    Bertagna, Francesco
    Prior, John O.
    Ceriani, Luca
    Giovanella, Luca
    ACADEMIC RADIOLOGY, 2014, 21 (01) : 11 - 20