X-ray spectral measurements of a dense plasma focus

被引:2
|
作者
Whitlock, RR [1 ]
Dozier, CM [1 ]
Newman, DA [1 ]
Petr, R [1 ]
Freshman, J [1 ]
Hoey, DW [1 ]
Heaton, JL [1 ]
机构
[1] USN, Res Lab, Washington, DC 20375 USA
关键词
dense plasma focus; X-ray lithography; X-ray spectrum;
D O I
10.1117/12.456515
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
Absolute intensities of spectra in a dense-plasma-focus (DPF) source have been recorded and analyzed. This DPF source has been identified as one of the more promising sources for X-ray lithography. The source, developed by Science Research Laboratory, Inc., is currently undergoing testing and further development at BAE Systems, Inc. The DPF operates at 60 Hz and produces an average output pulse of similar to5 J of X rays into 4pi steradians in a continuous operation mode. In all runs, there was an initial number of pulses, typically between 30 to 40, during which the X-ray output increased and the DPF appeared to be undergoing a conditioning process, and after which a "steady-state" mode was achieved where the average X-ray power was relatively constant. Each spectral run was exposed to similar to600 J of output, as measured by the PIN. The X-ray spectral region between 0.8 and 3 keV was recorded on Kodak DEF film in a potassium acid phthalate (KAP) convex curved-crystal spectrograph. The source emits neon line radiation from Ne IX and Ne X ionization stages in the 900 to 1300 eV region, suitable for lithographic exposures of photoresist. Two helium-like neon lines contribute more than 50% of the total energy. From continuum shape, plasma temperatures were found to be approximately 170-200. eV. The absolute, integrated spectral outputs were verified to within 30% by comparison with measurements by a PIN detector and a radiachromic X-ray dosimeter.
引用
收藏
页码:54 / 60
页数:7
相关论文
共 50 条
  • [21] STUDIES OF THE SPATIAL AND TEMPORAL EVOLUTION OF A DENSE-PLASMA FOCUS IN THE X-RAY REGION
    CHOI, P
    WONG, CS
    HEROLD, H
    LASER AND PARTICLE BEAMS, 1989, 7 : 763 - 772
  • [22] Dense plasma focus: different cathode geometries and their influence on the hard x-ray production
    Barbaglia, M.
    Giovachini, R.
    Milanese, M.
    PLASMA PHYSICS AND CONTROLLED FUSION, 2023, 65 (04)
  • [23] X-ray diffraction from a dense plasma
    Riley, D
    Woolsey, NC
    McSherry, D
    Weaver, I
    Djaoui, A
    Nardi, E
    PHYSICAL REVIEW LETTERS, 2000, 84 (08) : 1704 - 1707
  • [24] X-ray scattering as a dense plasma diagnostic
    Nardi, E
    Zinamon, Z
    Riley, D
    Woolsey, NC
    PHYSICAL REVIEW E, 1998, 57 (04): : 4693 - 4697
  • [25] X-ray scattering as a dense plasma diagnostic
    Nardi, Eran
    Zinamon, Zeev
    Riley, David
    Woolsey, Nigel C.
    Physical Review E. Statistical Physics, Plasmas, Fluids, and Related Interdisciplinary Topics, 1998, 57 (04):
  • [26] HARD X-RAY SPECTRUM OF A PLASMA FOCUS
    LEE, JH
    LOEBBAKA, DS
    ROOS, CE
    PLASMA PHYSICS, 1971, 13 (04): : 347 - &
  • [27] SPECTROSCOPIC AND X-RAY OBSERVATIONS OF A PLASMA FOCUS
    BERNSTEI.MJ
    HAI, F
    BULLETIN OF THE AMERICAN PHYSICAL SOCIETY, 1969, 14 (11): : 1077 - &
  • [28] Study of X-ray emission of dense plasma focus device in the presence of external magnetic field
    Mohanty, S. R.
    Srivastava, M. P.
    Rawat, R. S.
    Physics Letters. Section A: General, Atomic and Solid State Physics, 234 (06):
  • [29] Neutron anisotropy and X-ray production of the FN-II Dense Plasma Focus device
    Castillo, F
    Herrera, JJE
    Rangel, J
    Alfaro, A
    Maza, MA
    Sakaguchi, V
    Espinosa, G
    Golzarri, JI
    BRAZILIAN JOURNAL OF PHYSICS, 2002, 32 (01) : 3 - 12
  • [30] The effects of pre-ionization on the impurity and x-ray level in a dense plasma focus device
    Piriaei, D.
    Yousefi, H. R.
    Mahabadi, T. D.
    Elahi, A. Salar
    Ghoranneviss, M.
    PHYSICS OF PLASMAS, 2017, 24 (02)