An adjustable air-regulated siphon spillway

被引:3
|
作者
Hardwick, JD
Grant, DJ
机构
[1] Civil Engineering Department, Imperial College of Science, Technology and Medicine
关键词
D O I
10.1680/iwtme.1997.29772
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
The Pergau hydroelectric project was built as a design and construct contract in Northern Peninsular Malaysia by an Anglo-Malaysian joint venture with funding assistance provided by the British Government, A regulating pond providing 1.5 x 10(6) m(3) of live storage was constructed at the tailrace outfall to accept peak generation flows and release them back into the river in a controlled manner, Discharge from the pond is normally regulated by two hydraulically activated radial gates acting on signals from the project's automatic control system, An air-regulated siphon with a design capacity of 140 m(3)/s was provided to protect the embankment crest from overtopping in the event of gate malfunction or station generation flow continuing for longer than programmed, The spillway was developed with novel features in an extensive series of laboratory trials, Provision was made in the prototype to adjust the air intake area to compensate for scale effects in the model study and to ensure that the required head discharge relationship is obtained.
引用
收藏
页码:95 / 103
页数:9
相关论文
共 50 条
  • [21] Tests of a siphon-shaft spillway with cylindrical hoods
    Agiralioglu, N
    Sasal, M
    Karpuz, S
    WATER RESOURCES ENGINEERING 98, VOLS 1 AND 2, 1998, : 1440 - 1445
  • [22] KTESIBIOSS WATERCLOCK AND HERONS ADJUSTABLE SIPHON
    DRACHMANN, AG
    CENTAURUS, 1976, 20 (01) : 1 - 10
  • [23] Case study on hydraulic performance of Brent Reservoir siphon spillway
    Babaeyan-Koopaei, K
    Valentine, EM
    Ervine, DA
    JOURNAL OF HYDRAULIC ENGINEERING-ASCE, 2002, 128 (06): : 562 - 567
  • [24] Experiments for the Discharge Capacity of the Siphon Spillway Having the Creager - Ofitserov Profile
    Houichi, Larbi
    Ibrahim, Ghassan
    Achour, Bachir
    INTERNATIONAL JOURNAL OF FLUID MECHANICS RESEARCH, 2006, 33 (05) : 395 - 406
  • [25] AIR ENTRAINMENT BY SPILLWAY AERATORS
    RUTSCHMANN, P
    HAGER, WH
    JOURNAL OF HYDRAULIC ENGINEERING-ASCE, 1990, 116 (06): : 765 - 782
  • [26] STUDY OF AIR DEMAND ON SPILLWAY AERATOR
    CHANSON, H
    JOURNAL OF FLUIDS ENGINEERING-TRANSACTIONS OF THE ASME, 1990, 112 (03): : 343 - 350
  • [27] AIR ENTRAINMENT BY SPILLWAY AERATORS - DISCUSSION
    PINTO, NLD
    NEIDERT, SH
    OTA, JJ
    JOURNAL OF HYDRAULIC ENGINEERING-ASCE, 1992, 118 (01): : 114 - 116
  • [28] STEPPED SPILLWAY FLOWS AND AIR ENTRAINMENT
    CHANSON, H
    CANADIAN JOURNAL OF CIVIL ENGINEERING, 1993, 20 (03) : 422 - 435
  • [29] AIR ENTRAINMENT BY SPILLWAY AERATORS - CLOSURE
    RUTSCHMANN, P
    HAGER, WH
    JOURNAL OF HYDRAULIC ENGINEERING-ASCE, 1992, 118 (01): : 116 - 117
  • [30] NUMERICAL SIMULATION OF FLOW ON A SIPHON SPILLWAY AND INVESTIGATION OF THE EFFECT OF A BOTTOM/OUTLET ANGLE ON HYDRAULIC PARAMETERS
    Pakgar, Farshid
    Daneshfaraz, Rasoul
    Joudi, Ali Rezazadeh