PRACTICAL TESTS WITH R290 USED IN REEFER CONTAINER REFRIGERATION LEAKAGE TESTING

被引:0
|
作者
Koenig, Holger [1 ]
Bararu, Marius [2 ]
Holtappels, Kai [3 ]
机构
[1] Ref Tech Engn, Bechtersweiler 31, D-88131 Lindau, Germany
[2] Maersk Container Ind AS, Bjerndrupvej 47, DK-6360 Tinglev, Denmark
[3] BAM Fed Inst Mat Res & Testing, Unter Eichen 87, D-12205 Berlin, Germany
关键词
Reefer; safety; explosion protection; practice tests; leakage simulations; propane; flammable refrigerants;
D O I
10.18462/iir.gl.2016.1138
中图分类号
TH [机械、仪表工业];
学科分类号
0802 ;
摘要
The option of using flammable refrigerants in the reefer container has already been studied and reported by Konig (2013, 2014) in various publications. In the present paper, the results of experiments are presented, related to the investigation of the potential fire and explosions risks by R290 leaks in refrigerated containers. A safety concept for reefer containers operating with R290 as refrigerant has been tested and validated. In addition, there were extensive leakage simulations, the results have been evaluated for the comparison with the practical tests. Both experiments and the simulations were done at the Federal Institute for Materials Research and Testing (BAM). Further tests are carried out by the manufacturer with the support of the firefighting service and the Danish institute of Fire and Security Technology (DBI). The results from practical tests and the leakage simulations allow for first generalization and more precise studies with respect to potential risks of refrigerant leaks. Potentially explosive atmospheres situations can be evaluated much easier and appropriate measures can be derived. It turns out that dangerous situations for small, medium and rupture of pipe leaks are manageable. The results of the practical testing of leaking R290 inside and outside of a reefer container showed that the risk is being commonly overestimated.
引用
收藏
页码:845 / 852
页数:8
相关论文
共 50 条
  • [41] Experimental performance analysis of a packaged R290 refrigeration unit retrofitted with R170 for ultra-low temperature freezing
    Carlos Rodriguez-Criado, Juan
    Antonio Exposito-Carrillo, Jose
    Peris Perez, Bernardo
    Dominguez-Munoz, Fernando
    INTERNATIONAL JOURNAL OF REFRIGERATION, 2022, 134 : 105 - 114
  • [42] Energy and exergy analysis of zeotropic mixture R290/R600a vapor-compression refrigeration cycle with separation condensation
    Yan, Gang
    Cui, Chengfeng
    Yu, Jianlin
    INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2015, 53 : 155 - 162
  • [43] A new structure and theoretical analysis on leakage and performance of an oil-free R290 rolling piston compressor
    Wu, JianHua
    Chen, Ang
    INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2015, 49 : 110 - 118
  • [44] Development of novel wet sublimation cascade refrigeration system with binary mixtures of R744/R32 and R744/R290
    Sobieraj, Michal
    APPLIED THERMAL ENGINEERING, 2021, 196
  • [45] Thermodynamic comparison of various refrigerants for an on-board R290 refrigeration system with economizer subcooling in small fishing boats
    Singha, Prosenjit
    Das, Chayan
    Koster, Lukas
    Kochunni, Sarun Kumar
    Dasgupta, Mani Sankar
    Widell, Kristina Norne
    Bhattacharyya, Souvik
    Hafner, Armin
    THERMAL SCIENCE AND ENGINEERING PROGRESS, 2025, 60
  • [46] Performance evaluation of an ejector subcooling refrigeration cycle with zeotropic mixture R290/R170 for low-temperature freezer applications
    Liu, Ye
    Yu, Jianlin
    APPLIED THERMAL ENGINEERING, 2019, 161
  • [47] Thermodynamic analysis and performance optimization on an ultra-low-temperature cascade refrigeration system using refrigerants R290 and R170
    Ji, Shenrui
    Liu, Zhan
    Li, Jiafeng
    Wang, Tao
    ASIA-PACIFIC JOURNAL OF CHEMICAL ENGINEERING, 2024,
  • [48] Experimental investigation of the performance of a low-temperature refrigeration cycle using R170/R290 and R1150/R600a mixtures
    Monros-Andreu, G.
    Prades, L.
    Saez, A.
    Marin, E.
    Llopis, R.
    Patino, J.
    15TH IIR-GUSTAV LORENTZEN CONFERENCE ON NATURAL REFRIGERANTS, 2022, : 1764 - 1772
  • [49] Conventional and advanced exergy analysis of parallel and series compression-ejection hybrid refrigeration system for a household refrigerator with R290
    Zhao, Hongxia
    Yuan, Tianpeng
    Gao, Jia
    Wang, Xinli
    Yan, Jia
    ENERGY, 2019, 166 : 845 - 861
  • [50] A mathematical model of critical releasable charge for R290 indoor leakage of split-type household air conditioners
    Ning, Qian
    He, Guogeng
    Xiong, Jun
    Fan, Mingjing
    Li, Xiao
    BUILDING AND ENVIRONMENT, 2023, 228