The presence of arginine may be a source of false positive results in the Ames test

被引:12
|
作者
Khandoudi, Nassirah [1 ]
Porte, Pierre [1 ]
Chtourou, Sami [1 ]
Nesslany, Fabrice [2 ]
Marzin, Daniel [2 ,3 ]
Le Curieux, Frank [2 ,3 ]
机构
[1] Lab Francais Fractionnement & Biotechnol, F-91958 Les Ulis, Courtaboeuf, France
[2] Inst Pasteur, Toxicol Lab, EA2690, F-59019 Lille, France
[3] Fac Sci Pharmaceut & Biol, Dept Toxicol Sante Publ Environm, EA2690, F-59006 Lille, France
关键词
Salmonella typhimurium; Amino acids; Arginine; Artefact; False positive; HISTIDINE TRANSPORT COMPONENT; BACTERIAL MUTATION ASSAYS; SALMONELLA-TYPHIMURIUM; MUTAGENICITY TEST; NITRIC-OXIDE; N-NITROSAMINES; HISP PROTEIN; IDENTIFICATION; SUBSTANCES; SYSTEM;
D O I
10.1016/j.mrgentox.2009.03.010
中图分类号
Q81 [生物工程学(生物技术)]; Q93 [微生物学];
学科分类号
071005 ; 0836 ; 090102 ; 100705 ;
摘要
An increase in the number of revertant colonies in the Ames testis generally taken as a strong indication of mutagenic activity of a test compound. However. irrelevant positive findings may constitute a major problem in regulatory drug testing. In this study, mixtures containing only amino acids such as glycine, lysine, arginine and isoleucine, routinely used as peptide preservatives in polypeptide pharmaceutical products, were investigated for mutagenesis in the Ames Salmonella typhimurium test. The results demonstrated that in the presence of metabolic activation, all the solutions containing arginine induced an increase in the number of revertant colonies in strains TA98, TA100 and TA1535 compared with the solvent control. More specifically, for strain TA98, all arginine doses tested, i.e. from 0.4 to 8 mg/plate induced a statistically significant increase in the number of revertants. This increase was biologically significant from 1.2 to 8 mg/plate. For strain TA100, the five highest test doses, i.e. from 1.2 to 8 mg/plate, induced statistically and biologically significant increases in the number of revertants. A statistically significant increase in colony number was also observed in strain TA1535, but only at the maximal test dose of 8 mg/plate arginine. These increases were observed with arginine from two different sources, suggesting that the observed effect would not be due to the presence of potential impurities in the type of arginine used. Our findings show that a functional metabolic activation system was required to induce an increase in the number of colonies. The presence of vitamin C inhibited the arginine-induced increase in the number of revertant colonies in S. typhimurium strain TA98, suggesting a potential involvement of oxidative stress. (C) 2009 Elsevier B.V. All rights reserved.
引用
收藏
页码:65 / 71
页数:7
相关论文
共 50 条
  • [31] FALSE POSITIVE RESULTS WITH THE QUALITATIVE AMNIOTIC-FLUID ACETYLCHOLINESTERASE TEST
    READ, AP
    FENNELL, SJ
    DONNAI, D
    LANCET, 1981, 1 (8215): : 329 - 330
  • [32] ECHOVIRUS MENINGITIS AND FALSE-POSITIVE LYME TEST-RESULTS
    DEHART, DJ
    AVULA, R
    MUNNANGI, SR
    ANNALS OF INTERNAL MEDICINE, 1992, 116 (07) : 603 - 604
  • [33] The magnitude and challenge of false-positive newborn screening test results
    Kwon, C
    Farrel, PM
    ARCHIVES OF PEDIATRICS & ADOLESCENT MEDICINE, 2000, 154 (07): : 714 - 718
  • [34] Are the Harms of False-Positive Screening Test Results Minimal or Meaningful?
    Kroenke, Kurt
    JAMA INTERNAL MEDICINE, 2014, 174 (06) : 961 - 963
  • [35] Reducing False-Positive Pregnancy Test Results in Patients With Cancer
    McCash, Samuel I.
    Goldfrank, Deborah J.
    Pessin, Melissa S.
    Ramanathan, Lakshmi V.
    OBSTETRICS AND GYNECOLOGY, 2017, 130 (04): : 825 - 829
  • [36] Causes of false-positive HIV rapid diagnostic test results
    Klarkowski, Derryck
    O'Brien, Daniel P.
    Shanks, Leslie
    Singh, Kasha P.
    EXPERT REVIEW OF ANTI-INFECTIVE THERAPY, 2014, 12 (01) : 49 - 62
  • [37] False positive test results caused by inter-instrument contamination
    Robertson, GF
    Stallone, F
    Cyrus, S
    Caglioti, S
    TRANSFUSION, 2000, 40 (10) : 138S - 138S
  • [38] Vortioxetine use may cause false positive immunoassay results for urine methadone
    Uljon, Sacha
    Kataria, Yachana
    Flood, James G.
    CLINICA CHIMICA ACTA, 2019, 499 : 1 - 3
  • [39] Faulty washers and soiled micropipettors may generate false positive serological results
    Parry, JV
    Mortimer, PP
    Friderich, P
    Connell, JA
    CLINICAL AND DIAGNOSTIC VIROLOGY, 1997, 7 (03): : 173 - 181
  • [40] Hemorrhoids Are an Infrequent Cause of False Positive Fecal Immunochemical Test Results
    Van Turenhout, Sietze T.
    Oort, Frank A.
    Droste, Jochim S. Terhaar Sive
    van der Hulst, Rene W.
    Coupe, Veerle M.
    Bouman, Anneke A.
    Meijer, Gerrit A.
    van Rossum, Leo G.
    Mulder, Chris J.
    GASTROENTEROLOGY, 2011, 140 (05) : S418 - S418