Flexibility study for an MSF desalination plant

被引:2
|
作者
Tarifa, Enrique E. [1 ]
Franco, Samuel [1 ]
Humana, Demetrio [1 ]
Mussati, Sergio [2 ]
机构
[1] Univ Nacl Jujuy, CONICET, RA-4600 San Salvador De Jujuy, Argentina
[2] INGAR CONICET, RA-3000 Santa Fe, Argentina
关键词
Flexibility; Simulation; Monte Carlo; MSF; STEADY-STATE;
D O I
10.5004/dwt.2009.925
中图分类号
TQ [化学工业];
学科分类号
0817 ;
摘要
This work addresses a flexibility Study on a multi-stage flash (MSF) desalination plant. When any plant is designed, the engineers define the design for reaching optimal operation under nominal conditions. However, uncertain variables or disturbance cannot be handled to obtain those nominal conditions. For this reason, the design contains control elements for compensating the disturbance effects. This compensation is only possible into a region defined by the characteristics of the process and the control elements. When the actual conditions are out of that region, the compensation is not enough, and the plant is not operable. A flexibility study determines the region into which the process is operable. This information can be useful for determining design modifications to improve the process flexibility. A flexibility study involves a complex mathematical model, which is even more complex for a MSF plant. To perform the task, in this work, a stationary simulator was developed for a real-world case study, and the region exploration was performed by Monte Carlo simulation. Results show, in terms of both robustness and speed of computation, that this approach can be a useful tool.
引用
收藏
页码:229 / 237
页数:9
相关论文
共 50 条
  • [11] Exergy analysis of a MSF desalination plant in Yanbu, Saudi Arabia
    Al Ghamdi, Ahmed
    Mustafa, Ibrahim
    DESALINATION, 2016, 399 : 148 - 158
  • [12] Fault diagnosis for an MSF desalination plant by using Bayesian networks
    Tarifa, Enrique E.
    Alvaro, F. Nunez
    Franco, Samuel
    Mussati, Sergio
    DESALINATION AND WATER TREATMENT, 2010, 21 (1-3) : 102 - 108
  • [13] A comparative study of RO and MSF desalination plants
    AlMutaz, IS
    DESALINATION, 1996, 106 (1-3) : 99 - 106
  • [14] Design of robust SISO PI controllers for a MSF desalination plant
    Chidambaram, M
    Reddy, BC
    AlGobaisi, DMK
    DESALINATION, 1997, 109 (02) : 109 - 119
  • [15] Copper dust formation in a large scale MSF desalination plant
    Al-Kawari, M
    Al-Bastaki, N
    DESALINATION, 2004, 166 (1-3) : 153 - 156
  • [16] SEAWATER DESALINATION PLANT SIRTE - AN EXAMPLE FOR AN ADVANCED MSF DESIGN
    TUSEL, GF
    RAUTENBACH, R
    WIDUA, J
    DESALINATION, 1994, 96 (1-3) : 379 - 396
  • [17] Performance analysis of a trihybrid NF/RO/MSF desalination plant
    Hamed, Osman A.
    Hassan, Ata M.
    Al-Shail, Khalid
    Farooque, Mohammed A.
    DESALINATION AND WATER TREATMENT, 2009, 1 (1-3) : 215 - 222
  • [18] MSF nuclear desalination
    Faibish, RS
    Ettouney, H
    DESALINATION, 2003, 157 (1-3) : 277 - 287
  • [19] Variable frequency drives for MSF desalination plant and associated pumping stations
    Camoirano, R
    Dellepiane, G
    DESALINATION, 2005, 182 (1-3) : 53 - 65
  • [20] CORROSION PROBLEMS AND THEIR PREVENTIONS OF MSF DESALINATION PLANT CONSTRUCTED WITH TITANIUM TUBE
    FUKUZUKA, T
    SHIMOGORI, K
    SATOH, H
    KAMIKUBO, F
    DESALINATION, 1979, 31 (1-3) : 389 - 398