Effect of Regeneration Section Angle on the Performance of a Rotary Desiccant Wheel

被引:14
|
作者
Muthu, Selvaraji [1 ]
Talukdar, Prabal [1 ]
Jain, Sanjeev [1 ]
机构
[1] Indian Inst Technol Delhi, Dept Mech Engn, New Delhi 110016, India
关键词
coupled heat and mass transfer; desiccant isotherm; RD silica gel; composite desiccant; rotary desiccant wheel; adjustable regeneration section split ratio;
D O I
10.1115/1.4030966
中图分类号
O414.1 [热力学];
学科分类号
摘要
In this work, the governing equations of coupled heat and mass transfer are developed based on the conservation of energy and moisture in air and desiccant layer of a rotary desiccant wheel in order to consider both the solid-side resistance (SSR) and gas-side resistance (GSR). The simulations are done for composite desiccant and conventional silica gel. The properties of air and desiccant are taken as function of temperature in the adsorption and regeneration sections. The governing partial differential equations are discretized using the finite-volume method with fully implicit scheme and the resulting system of algebraic equations is solved using the Gauss-Seidel method. The model is validated for the moisture removal capacity and relative moisture removal efficiency by comparing the present results with the literature data. The parametric simulations are performed by varying one parameter at a time with the angle of regeneration section kept in a range from 60 deg to 300 deg. The selection of regeneration section angle and temperature of regeneration air is discussed for operating the rotary desiccant wheel at its optimum performance for the range of operating conditions.
引用
收藏
页数:9
相关论文
共 50 条
  • [41] Integration of a rotary desiccant wheel into a hot-air drying system: Drying performance and product quality studies
    Madhiyanon, Thanid
    Adirekrut, Sermpong
    Sathitruangsak, Prasan
    Soponronnarit, Somchart
    CHEMICAL ENGINEERING AND PROCESSING-PROCESS INTENSIFICATION, 2007, 46 (04) : 282 - 290
  • [42] Performance investigation of an internally cooled desiccant wheel
    Zhou, Xingchao
    Goldsworthy, Mark
    Sproul, Alistair
    APPLIED ENERGY, 2018, 224 : 382 - 397
  • [43] Performance of solar liquid desiccant regeneration
    Qian, Junfei
    Yin, Yonggao
    Zhang, Xiaosong
    Gao, Longfei
    Zhang, Youchao
    Huagong Xuebao/CIESC Journal, 2014, 65 : 272 - 279
  • [44] Performance evaluation of a rotary dehumidifier with molecular sieve desiccant using coupled regeneration mode: Experimental investigation
    Mehare, Hussam Bin
    Hussain, Taliv
    Zia, Mohd Aqib
    Saleem, Saif
    Energy and Built Environment, 2025, 6 (02): : 219 - 229
  • [45] Solar powered air conditioning system using rotary honeycomb desiccant wheel
    Kabeel, A. E.
    RENEWABLE ENERGY, 2007, 32 (11) : 1842 - 1857
  • [46] Interpolation methods to predict the influence of inlet airflow states on desiccant wheel performance at low regeneration temperature
    Ruivo, Celestino R.
    Goldsworthy, Mark
    Intini, Manuel
    ENERGY, 2014, 68 : 765 - 772
  • [47] Energy consumption analysis on a dedicated outdoor air system with rotary desiccant wheel
    Liu, Weiwei
    Lian, Zhiwei
    Radermacher, Reinhard
    Yao, Ye
    ENERGY, 2007, 32 (09) : 1749 - 1760
  • [48] FABRICATION AND EXPERIMENTAL STUDY OF REGENERATION TEMPERATURE, ROTATIONAL SPEED AND INLET AIR HUMIDITY ON THE PERFORMANCE OF A DESICCANT WHEEL
    Zendehboudi, A. R.
    Hashemi, R.
    IRANIAN JOURNAL OF SCIENCE AND TECHNOLOGY-TRANSACTIONS OF MECHANICAL ENGINEERING, 2015, 39 (M2) : 451 - 458
  • [49] Optimization of desiccant wheel speed and area ratio of regeneration to dehumidification as a function of regeneration temperature
    Chung, Jae Dong
    Lee, Dae-Young
    Yoon, Seok Mann
    SOLAR ENERGY, 2009, 83 (05) : 625 - 635
  • [50] Superheated Steam Regeneration of a Desiccant Wheel-Experimental Results and Comparison with Air Regeneration
    Goldsworthy, M. J.
    Alessandrini, S.
    White, S. D.
    DRYING TECHNOLOGY, 2015, 33 (04) : 471 - 478