Detection of coagulating blood under steady flow by statistical analysis of backscattered signals

被引:25
|
作者
Huang, Chih-Chung [1 ]
Tsui, Po-Hsiang
Wang, Shyh-Hau
机构
[1] Chung Yuan Christian Univ, Dept Biomed Engn, Chungli 32023, Taiwan
[2] Chung Yuan Christian Univ, R&D Ctr Membrane Technol, Chungli 32023, Taiwan
[3] Acad Sinica, Div Mech, Res Ctr Appl Sci, Taipei 11529, Taiwan
关键词
D O I
10.1109/TUFFC.2007.258
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
The main purpose of this study is to detect blood coagulation under flow condition by analyzing Nakagami statistical model of backscattered signals. The radiofrequency (RF) signals backscattered from flowing blood were measured with a 10-MHz focused transducer. A 30-ml aliquot of blood was circulated in the flow model, and 3 ml of 0.5 M calcium chloride solution was added to induce blood coagulation. The progression in the blood coagulation due to the addition of the calcium chloride solution resulted in the integrated backscatter being increased by 4.2 +/- 0.5 dB, then tended to stabilize as the clot was formed. The Nakagami parameter was approximately 0.75 +/- 0.1 for flowing blood during the initial stage of blood coagulation, and it increased rapidly to its highest level of 2.6 +/- 0.5 during clotting. These experimental results demonstrate the feasibility of using the ultrasonic statistical parameter for detecting blood coagulation from flowing blood and provide a novel method for further monitoring the progress of clotting and thrombosis in vivo.
引用
收藏
页码:435 / 442
页数:8
相关论文
共 50 条
  • [41] Statistical Analysis on the Signals Monitoring Multiphase Flow Patterns in Pipeline-Riser System
    Ye, Jing
    Guo, Liejin
    7TH INTERNATIONAL SYMPOSIUM ON MULTIPHASE FLOW, HEAT MASS TRANSFER AND ENERGY CONVERSION, 2013, 1547 : 221 - 229
  • [42] PREDICTION OF THE FAILURE OF A STRUCTURE BY STATISTICAL-ANALYSIS OF PAUSES IN A FLOW OF ACOUSTIC-SIGNALS
    KRASILNIKOV, AZ
    PETROV, VA
    MECHANICS OF COMPOSITE MATERIALS, 1992, 28 (03) : 245 - 250
  • [43] Novel algorithm for reliable detection of beat onsets in cerebral blood flow velocity signals
    Canac, N.
    Thorpe, S.
    Ranjbaran, M.
    O'Brien, M.
    Thibeault, C.
    Wilk, S.
    Hamilton, R.
    Scalzo, F.
    EUROPEAN JOURNAL OF NEUROLOGY, 2018, 25 : 59 - 60
  • [44] Transition to Turbulence Downstream of a Stenosis for Whole Blood and a Newtonian Analog Under Steady Flow Conditions
    Costa, Rayanne Pinto
    Nwotchouang, Blaise Simplice Talla
    Yao, Junyao
    Biswas, Dipankar
    Casey, David
    McKenzie, Ruel
    Steinman, David A.
    Loth, Francis
    JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 2022, 144 (03):
  • [45] A digital twin model of traffic flow load for full bridge deck geared to analysis of bridge mechanical effects under statistical steady state
    Dan, Danhui
    Pan, Ruiyang
    Kong, Zhaowen
    Yan, Xingfei
    STRUCTURES, 2025, 73
  • [46] Statistical Analysis of Wrist Pulse Signals Obtained Under Different Food Intake Conditions
    Rangaprakash, D.
    2014 INTERNATIONAL CONFERENCE ON COMMUNICATIONS AND SIGNAL PROCESSING (ICCSP), 2014,
  • [47] Analysis of Energy Detection of Unknown Signals under Beckmann Fading Channels
    Pena-Martin, Juan P.
    Romero-Jerez, Juan M.
    Javier Lopez-Martinez, F.
    2017 IEEE 85TH VEHICULAR TECHNOLOGY CONFERENCE (VTC SPRING), 2017,
  • [48] Balanced detection of correlated incoherent signals: A statistical analysis of intensity noise with experimental validation
    Abtahi, Mohammad
    Ayotte, Simon
    Penon, Julien
    Rusch, Leslie A.
    JOURNAL OF LIGHTWAVE TECHNOLOGY, 2008, 26 (9-12) : 1330 - 1338
  • [49] Crowd behaviour analysis and anomaly detection by statistical modelling of flow patterns
    Pathan, Saira Saleem
    Al-Hamadi, Ayoub
    Michaelis, Bernd
    INTERNATIONAL JOURNAL OF DATA MINING MODELLING AND MANAGEMENT, 2014, 6 (02) : 168 - 186
  • [50] Detection of local preform defects by gas flow method and statistical analysis
    Kim, SK
    Opperer, JG
    Daniel, IM
    ADVANCED COMPOSITES LETTERS, 2003, 12 (03) : 109 - 114