Dielectric Dissipation factor measurements on stator insulation - results from a global survey

被引:0
|
作者
Krieg-Wezelenburg, M. G. [1 ]
机构
[1] CIGRE, Paris, France
关键词
Dielectric Dissipation Factor; Electrical Insulation Systems; Stator bar/coil; Tip-up; SYSTEMS;
D O I
10.1109/eic47619.2020.9158740
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Dielectric Dissipation Factor (DDF) measurements are used to assess the manufacturing quality of individual stator bars/coils and the dielectric behavior of the electrical insulation system of stator windings. The use of this diagnostic test method is widespread and standardized in IEEE and IEC documents. The new IEC 60034-27-3 document sets acceptance limits for individual stator bars and coils based on parameters such as the absolute value of DDF and DDF tip-up at specified voltages. These requirements are viewed by some as too restrictive and by others as overly lenient. Therefore, in 2012, CIGRE established a working group to survey experience with and collect data on DDF testing of newly manufactured stator bars and coils on a worldwide basis. The collected DDF measurement results were analyzed in relation to various influence factors and the results were incorporated in a technical brochure. This contribution will discuss some of the key findings of this work of great significance that was published by CIGRE in 2019.
引用
收藏
页码:269 / 273
页数:5
相关论文
共 50 条
  • [31] Coseismic Displacements from the Hector Mine, California, earthquake: Results from survey-mode global positioning system measurements
    Agnew, DC
    Owen, S
    Shen, ZK
    Anderson, G
    Svarc, J
    Johnson, H
    Austin, KE
    Reilinger, R
    BULLETIN OF THE SEISMOLOGICAL SOCIETY OF AMERICA, 2002, 92 (04) : 1355 - 1364
  • [32] Estimation of Paper Moisture Content based on Dielectric Dissipation Factor of Oil-paper Insulation under Non-sinusoidal Excitations
    Pradhan, A. K.
    Chatterjee, B.
    Chakravorti, S.
    IEEE TRANSACTIONS ON DIELECTRICS AND ELECTRICAL INSULATION, 2015, 22 (02) : 822 - 830
  • [33] Diagnostics of power system cable lines on dielectric dissipation factor and impregnated-paper insulation self-discharge time constant
    Naboka, B. G.
    Bezprozvannych, A. V.
    Moscvitin, E. S.
    Bytko, M. V.
    Bytko, S. M.
    Golovan, A. A.
    ELECTRICAL ENGINEERING & ELECTROMECHANICS, 2011, (02) : 65 - 69
  • [34] Global Burden Of Asthma, Results From The World Health Survey
    To, T.
    Boulet, L. -P.
    Feldman, R.
    Moores, G.
    McLimont, S.
    Daly, C.
    Gershon, A. S.
    AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 2011, 183
  • [35] Global trends in migraine care - Results from the MAZE survey
    Brandes, JL
    CNS DRUGS, 2002, 16 (Suppl 1) : 13 - 18
  • [36] Palliative Care in Public Policy: Results from a Global Survey
    Clelland, David
    van Steijn, Danny
    Whitelaw, Sandy
    Connor, Stephen
    Centeno, Carlos
    Clark, David
    PALLIATIVE MEDICINE REPORTS, 2020, 1 (01): : 183 - 190
  • [37] Religiosity and Attitudes towards Robots: Results from a Global Survey
    Webster, Craig
    Nov, Stanislaviva
    SCIENTIA ET FIDES, 2024, 12 (02): : 197 - 215
  • [38] Bioeconomy from experts' perspectives - Results of a global expert survey
    Issa, Irwa
    Delbrueck, Sebastian
    Hamm, Ulrich
    PLOS ONE, 2019, 14 (05):
  • [39] Accurate Extraction of High Quality Factor of Dielectric Resonators from Measurements
    Lei, Dajun
    Qiu, Feng
    Zhang, Jinggui
    Dong, Hui
    Tang, Zhenghua
    Huang, Jianquan
    Yao, Min
    Chu, Qing-Xin
    PROGRESS IN ELECTROMAGNETICS RESEARCH LETTERS, 2016, 62 (62): : 77 - 82
  • [40] Comparison of the mineral oil lifetime estimates obtained by differential scanning calorimetry, infrared spectroscopy, and dielectric dissipation factor measurements
    Polansky, R.
    Prosr, P.
    Vik, R.
    Moravcova, D.
    Pihera, J.
    THERMOCHIMICA ACTA, 2017, 647 : 86 - 93