Influence of the presence of an upstream annular liquid film on the wet gas flow measured by a Venturi in a downward vertical configuration

被引:20
|
作者
Lupeau, A.
Platet, B.
Gajan, P.
Strzelecki, A.
Escande, J.
Couput, J. P.
机构
[1] Off Natl Etud & Rech Aerosp, Off Natl Etud & Rech Aerosp, F-31055 Toulouse, France
[2] Gaz France, Direct Rech, F-94140 Alfortville, France
[3] Total, F-64018 Pau, France
关键词
gas; annular flow; film thickness; Venturi meter; modelling;
D O I
10.1016/j.flowmeasinst.2006.09.002
中图分类号
TH [机械、仪表工业];
学科分类号
0802 ;
摘要
This work is included in an overall study linked to the production of gas from high pressure natural reservoirs. During the extraction of the gas, a liquid phase appears as condensates and water. In many applications the gas volume fraction (GVF) is high and the flow can be considered as a wet gas. The exact metering of the extracted gas necessitates gas/liquid separation. In order to reduce the costs, another solution is to measure the whole flow with a single flow meter. Among the different methods on the market, the use of the Venturi meter is nowadays still widespread. Different empirical correlations based on a Lockhart-Martinelli parameter were proposed to take into account the liquid phase, in the gas flow rate measurement. Nevertheless the accuracy of these correlations is not sufficient for allocation or reservoir monitoring. In fact these correlations do not take into account the influence of the two phase flow characteristics in the pipe upstream of the flow meter. To improve the metering method, a research program based on modelling and experimental tests has been developed by Total, Gaz de France and ONERA. In this paper, experimental results on the influence of the liquid film characteristics on the Venturi pressure drop (Delta P) are presented. Visualizations of the film upstream and inside the Venturi meter are shown. They are completed by film thickness wave amplitude and wavelength measurements. The Delta P measurements indicate that for the same Lockhart-Martinelli parameter, the characteristics of the liquid film have a great influence on the correlation coefficient. A one dimensional model is proposed which evaluates the influence of the different phenomena occurring between the two pressure taps. (c) 2006 Elsevier Ltd. All rights reserved.
引用
收藏
页码:1 / 11
页数:11
相关论文
共 50 条
  • [21] HYDRODYNAMICS OF DOWNWARD TURBULENT-FLOW OF A LIQUID-GAS FILM
    FEDOTKIN, IM
    IVANOV, VS
    LIPSMAN, VS
    CHEPURNOI, MN
    SHNAIDER, VE
    INTERNATIONAL CHEMICAL ENGINEERING, 1975, 15 (02): : 296 - 298
  • [22] Influence of Liquid Viscosity and Geometry on Vertical Gas/Liquid Two-Phase Annular-Duct Flow
    Almeida Colmanetti, Alex Roger
    de Castro, Marcelo Souza
    Barbosa, Marcel Cavailini
    Hernandez Rodriguez, Oscar Mauricio
    SPE JOURNAL, 2020, 25 (06): : 3236 - 3249
  • [23] An optimize empirical correlations for liquid film thickness and interfacial friction factor in vertical gas-liquid annular flow
    Ghafouri, Arash
    Ghafouri, Ashkan
    Kosarineia, Abbas
    Daneh-Dezfuli, Alireza
    JOURNAL OF THE TAIWAN INSTITUTE OF CHEMICAL ENGINEERS, 2023, 148
  • [24] Prediction of the liquid film reversal of annular flow in vertical and inclined pipes
    Wang, Li-song
    Liu, Shuo
    Hou, Lin-tong
    Yang, Meng
    Zhang, Jian
    Xu, Jing-yu
    INTERNATIONAL JOURNAL OF MULTIPHASE FLOW, 2022, 146
  • [25] TRANSITION TO ANNULAR-FLOW IN VERTICAL UPWARD GAS-LIQUID FLOW
    SYLVESTER, ND
    AICHE JOURNAL, 1984, 30 (04) : 700 - 700
  • [26] EFFECT OF ENTRAINMENT ON LIQUID FILM DRYOUT IN VERTICAL UPWARD ANNULAR FLOW
    Wu, Zan
    Wadekar, Vishwas
    Sunden, Bengt
    PROCEEDINGS OF THE ASME SUMMER HEAT TRANSFER CONFERENCE, 2016, VOL 2, 2016,
  • [27] TRANSITION TO ANNULAR-FLOW IN VERTICAL UPWARD GAS-LIQUID FLOW
    CHEN, JJJ
    SPEDDING, PL
    AICHE JOURNAL, 1983, 29 (03) : 525 - 525
  • [28] Performance of a Venturi meter in gas-liquid flow in the presence of dissolved gases
    Elperin, T
    Fominykh, A
    Klochko, M
    FLOW MEASUREMENT AND INSTRUMENTATION, 2002, 13 (1-2) : 13 - 16
  • [29] MODELING OF VERTICAL DOWNWARD GAS-LIQUID FLOW FOR THE DESIGN OF A NEW CONTACTOR
    ROUSTAN, M
    LINE, A
    WABLE, O
    CHEMICAL ENGINEERING SCIENCE, 1992, 47 (13-14) : 3681 - 3688
  • [30] VERTICAL UPWARD COCURRENT GAS-LIQUID ANNULAR-FLOW
    ZABARAS, G
    DUKLER, AE
    MOALEMMARON, D
    AICHE JOURNAL, 1986, 32 (05) : 829 - 843