Changes in anterior and posterior corneal curvatures in keratoconus

被引:179
|
作者
Tomidokoro, A
Oshika, T
Amano, S
Higaki, S
Maeda, N
Miyata, K
机构
[1] Omiya Red Cross Hosp, Dept Ophthalmol, Urawa, Saitama 3380001, Japan
[2] Univ Tokyo, Sch Med, Dept Ophthalmol, Tokyo 113, Japan
[3] Osaka Univ, Sch Med, Dept Ophthalmol, Osaka, Japan
[4] Miyata Eye Hosp, Miyazaki, Japan
关键词
D O I
10.1016/S0161-6420(00)00159-7
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Objective: To quantitatively evaluate the changes in anterior and posterior corneal curvatures of eyes with keratoconus. Design: Case-control retrospective and observational study. Participants: Thirty-one patients who were clinically diagnosed to have unilateral or bilateral keratoconus and 18 normal subjects. Intervention: The anterior and posterior topographies were obtained using scanning-slit videokeratography and assessed by Fourier series harmonic analysis. Main Outcome Measures: Quantitative descriptors of the topography data, spherical power, regular astigmatism, and irregular astigmatism (asymmetry and higher order irregularity) components were compared between the anterior and posterior surfaces and among groups of clinically diagnosed keratoconus (33 eyes), keratoconus suspect (13 eyes), and normal subjects (36 eyes). Results: Spherical power (P = 0.0003, Mann-Whitney U test with Bonferroni's correction of P values), regular astigmatism (P = 0.0166), and asymmetry (P = 0.0031) of the anterior surface were significantly greater in the keratoconus eyes than in the normal controls. For the posterior surface, spherical power (P < 0.0001), regular astigmatism (P = 0.0143), asymmetry (P < 0.0001), and higher order irregularity (P = 0.0032) of the keratoconus group were significantly greater than those of the control group. The keratoconus suspect eyes, when compared with the normal controls, showed a significantly greater amount of spherical power (P = 0.0166) and asymmetry (P < 0.0001) in the anterior surface and spherical power (P < 0.0001), regular astigmatism (P = 0.0244), asymmetry (P < 0.0001), and higher order irregularity (P = 0.0276) in the posterior surface. All refractive components demonstrated statistically significant correlations between the anterior and posterior surfaces (P < 0.0001, Spearman's rank correlation). Conclusions: Not only the anterior but also the posterior corneal curvature is affected in keratoconus. These changes are observed from the early stage of this disorder. (C) 2000 by the American Academy of Ophthalmology.
引用
收藏
页码:1328 / 1332
页数:5
相关论文
共 50 条
  • [21] Relationship between corneal swelling and anterior and posterior corneal curvature changes
    Cornish, Ruth
    Brennan, Noel A
    Jaworski, Andrew
    Optometry and Vision Science, 2000, 77 (12 SUPPL.)
  • [22] Anterior and posterior corneal higher-order aberrations in early diagnosis and grading of keratoconus
    Yekta, Abbasali
    Hashemi, Hassan
    Ostadimoghaddam, Hadi
    Hadizadeh, Mohsen
    Rafati, Shokoofeh
    Doostdar, Asgar
    Nabovati, Payam
    Sadoughi, Mohammad Mehdi
    Khabazkhoob, Mehdi
    CLINICAL AND EXPERIMENTAL OPTOMETRY, 2023, 106 (03) : 263 - 270
  • [23] Automated keratoconus detection using data from anterior and posterior corneal surface.
    Bessho, K
    Maeda, N
    Kuroda, T
    Oshika, T
    Fujikado, T
    Tano, Y
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2001, 42 (04) : S894 - S894
  • [24] Characteristics of Corneal Astigmatism of Anterior and Posterior Surface in a Normal Control Group and Patients With Keratoconus
    Shajari, Mehdi
    Friderich, Stefan
    Sadeghian, Miad Pour
    Schmack, Ingo
    Kohnen, Thomas
    CORNEA, 2017, 36 (04) : 457 - 462
  • [25] A hybrid deep learning framework for keratoconus detection based on anterior and posterior corneal maps
    Al-Timemy, Ali H.
    Hazarbassanov, Rossen M.
    Mosa, Zahraa M.
    Alyasseri, Zaid
    Lavric, Alexandru
    Oliveira da Rosa, Claudio Alan
    Griz, Camila Palmeira
    Takahashi, Hidenori
    Yousefi, Siamak
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2021, 62 (11)
  • [26] I year posterior corneal changes after Bowman Layer Transplant for keratoconus
    Tourkmani, Abdo Karim
    Lyons, Conor
    Hossain, Parwez N.
    Konstantopoulos, Aristides
    Anderson, David F.
    Alio, Jorge L.
    EUROPEAN JOURNAL OF OPHTHALMOLOGY, 2022, 32 (03) : 1370 - 1374
  • [27] Association between anterior and posterior keratoconus
    Vajpayee, RB
    Sharma, N
    AUSTRALIAN AND NEW ZEALAND JOURNAL OF OPHTHALMOLOGY, 1998, 26 (02): : 181 - 183
  • [28] Changes in the anterior and posterior radii of the corneal curvature and anterior chamber depth by orthokeratology
    Tsukiyama, Junko
    Miyamoto, Yuko
    Higaki, Shiro
    Fukuda, Masahiko
    Shimomura, Yoshikazu
    EYE & CONTACT LENS-SCIENCE AND CLINICAL PRACTICE, 2008, 34 (01): : 17 - 20
  • [29] Direct measurement of anterior corneal curvature changes attributable to epithelial removal in keratoconus
    Ziaei, Mohammed
    Meyer, Jay
    Gokul, Akilesh
    Vellara, Hans
    McGhee, Charles N. J.
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2018, 44 (01): : 71 - 77
  • [30] Changes of Corneal Biomechanics With Keratoconus
    Wolffsohn, James S.
    Safeen, Saima
    Shah, Sunil
    Laiquzzaman, Mohammad
    CORNEA, 2012, 31 (08) : 849 - 854