Results of dynamic condylar screw for subtrochanteric fractures

被引:34
|
作者
Kulkarni, SS [1 ]
Moran, CG [1 ]
机构
[1] Univ Nottingham Hosp, Dept Trauma & Orthopaed, Nottingham NG7 2UH, England
关键词
D O I
10.1016/S0020-1383(02)00085-2
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
A consecutive series of 58 patients, treated with the dynamic condylar screw (DCS) for subtrochanteric fractures were retrospectively reviewed. The mechanism of injury was low-energy in 47 cases and high-energy in 11 cases. Five patients died before fracture healing. Ten out of 1 1 young patients, (nine with high-energy injuries), united primarily. In contrast, the primary union rate in the elderly was 74%. Implant failure was seen in 11 cases (20%). Restricted weight bearing status post-operatively was associated with significantly lower incidence of implant failure (P < 0.05, chi(2)-test). The use of bone graft was not related to fracture union (P > 0.5). After revision surgery the overall union rate in the elderly was 90%. Using the DCS, the results were good in the young patients with high-energy injuries. However, the implant failure rate is high in elderly patients who suffer low-energy fractures. The DCS should not be used if weight bearing cannot be minimized in this group. (C) 2003 Elsevier Science Ltd. All rights reserved.
引用
收藏
页码:117 / 122
页数:6
相关论文
共 50 条
  • [41] 6-YEAR EXPERIENCE WITH THE DYNAMIC CONDYLAR SCREW IN SUPRACONDYLAR AND INTERCONDYLAR FRACTURES
    BABST, R
    ROSSO, R
    MARX, A
    HESS, P
    REGAZZONI, P
    HELVETICA CHIRURGICA ACTA, 1991, 57 (05) : 821 - 824
  • [42] APPLICATION OF THE DYNAMIC CONDYLAR SCREW DYNAMIC HIP SCREW IN THE EQUINE
    AUER, JA
    VETERINARY SURGERY, 1987, 16 (01) : 81 - 82
  • [43] LOW-ENERGY SUBTROCHANTERIC FRACTURES IN ELDERLY PATIENTS - RESULTS OF FIXATION WITH THE SLIDING SCREW PLATE
    MULLAJI, AB
    THOMAS, TL
    JOURNAL OF TRAUMA-INJURY INFECTION AND CRITICAL CARE, 1993, 34 (01): : 56 - 61
  • [44] Subtrochanteric Femoral Fractures Treated by Condylar Plate, A study of 56 cases
    Laghari, Muhammad Ayoob
    Makhdoom, Asadullah
    Pahore, Muhammad Khan
    Memon, Abass
    JOURNAL OF THE LIAQUAT UNIVERSITY OF MEDICAL AND HEALTH SCIENCES, 2012, 11 (02): : 54 - 59
  • [45] Minimally invasive percutaneous plating of distal femoral fractures using the dynamic condylar screw
    Jeon, IH
    Oh, CW
    Kim, SJ
    Park, BC
    Kyung, HS
    Ihn, JC
    JOURNAL OF TRAUMA-INJURY INFECTION AND CRITICAL CARE, 2004, 57 (05): : 1048 - 1052
  • [46] TREATMENT OF UNSTABLE FRACTURES OF THE PROXIMAL FEMUR USING THE DYNAMIC CONDYLAR SCREW - ARE THERE ADVANTAGES IN GERONTOTRAUMATOLOGY
    BAUMER, F
    JUROWICH, B
    TARUTTIS, H
    ZENTRALBLATT FUR CHIRURGIE, 1992, 117 (08): : 460 - 464
  • [47] Treatment Outcome of Sub-Trochanteric Fractures of Femur Fixed with Dynamic Condylar Screw
    Mirza, Muhammad Iqbal
    Gillani, Syed Faraz Ul Hassan Shah
    Raza, Javed Hassan
    Nadeem, Ana Dilawaiz
    ANNALS OF KING EDWARD MEDICAL UNIVERSITY LAHORE PAKISTAN, 2018, 24 (04): : 913 - 917
  • [48] 1ST EXPERIENCES WITH THE DYNAMIC CONDYLAR SCREW (DCS) IN DISTAL FEMUR FRACTURES
    REGAZZONI, P
    LEUTENEGGER, A
    RUEDI, T
    STAEHELIN, F
    HELVETICA CHIRURGICA ACTA, 1986, 53 (1-2) : 61 - 64
  • [49] Custom 95° condylar blade plate for pediatric subtrochanteric femur fractures
    Segal, LS
    ORTHOPEDICS, 2000, 23 (02) : 103 - 107
  • [50] Indirect reduction with a condylar blade plate for osteosynthesis of subtrochanteric femoral fractures
    Siebenrock, KA
    Müller, U
    Ganz, R
    INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 1998, 29 : 7 - 15