Cortical mapping and frameless stereotactic navigation in the high-field intraoperative magnetic resonance imaging suite Technical note

被引:28
|
作者
Weingarten, David M.
Asthagiri, Ashok R.
Butman, John A. [4 ]
Sato, Susumu [2 ]
Wiggs, Edythe A. [3 ]
Damaska, Bonita [4 ]
Heiss, John D. [1 ]
机构
[1] Natl Inst Neurol Disorders & Stroke, Surg Neurol Branch, NIH, Bethesda, MD 20892 USA
[2] Natl Inst Neurol Disorders & Stroke, Clin Epilepsy Sect, Bethesda, MD 20892 USA
[3] Natl Inst Neurol Disorders & Stroke, Dev & Metab Neurol Branch, Bethesda, MD 20892 USA
[4] NIH, Ctr Clin, Dept Diagnost Radiol, Bethesda, MD 20892 USA
基金
美国国家卫生研究院;
关键词
brain mapping; intraoperative magnetic resonance imaging; brain tumor surgery; stereotactic techniques; LOW-GRADE GLIOMAS; ELECTRICAL-STIMULATION; MOTOR CORTEX; CEREBRAL-CORTEX; FUNCTIONAL MRI; LOCALIZATION; RESECTION; NEUROSURGERY; GUIDANCE; SURGERY;
D O I
10.3171/2009.5.JNS09164
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Frameless stereotactic neuronavigation provides tracking of surgical instruments on radiographic images and orients the surgeon to tumor margins at surgery. Bipolar electrical stimulation mapping (ESM) delineates safe limits for resection of brain tumors adjacent to eloquent cortex. These standard techniques could complement the capability of intraoperative MR (iMR) imaging to evaluate for occult residual disease during surgery and promote more complete tumor removal. The use of frameless neuronavigation in the high-field iMR imaging suite requires that a few pieces of standard equipment be replaced by nonferromagnetic instruments. Specific use of ESM in a high-field iMR imaging suite has not been reported in the literature. To study whether frameless neuronavigation and electrical stimulation mapping could be successfully integrated in the high-field iMR imaging suite, the authors employed these modalities in 10 consecutive cases involving patients undergoing conscious craniotomy for primary brain tumors located in or adjacent to eloquent cortices. Equipment included a custom high-field MR imaging -compatible head holder and dynamic reference frame attachment, a standard MR imaging -compatible dynamic reference frame, a standard MR imaging machine with a table top that could be translated to a pedestal outside the 5-gauss line for the operative intervention, and standard neuronavigational and cortical stimulation equipment. Both ESM and frameless stereotactic guidance were performed outside the 5-gauss line. The presence of residual neoplasm was evaluated using iMR imaging; resection was continued until eloquent areas were encountered or iMR imaging confirmed complete removal of any residual tumor. Mapping identified essential language (5 patients), sensory (6), and motor (7) areas. The combined use of frameless stereotactic navigation, ESM, and iMR imaging resulted in complete radiographic resection in 7 cases and resection to an eloquent margin in 3 cases. Postoperative MR imaging confirmed final iMR imaging findings. No patient experienced a permanent new neurological deficit. Familiar techniques such as frameless navigation and ESM can be rapidly, inexpensively, safely, and effectively integrated into the high-field iMR imaging suite. (DOI: 10.3171/2009.5.JNS09164)
引用
收藏
页码:1185 / 1190
页数:6
相关论文
共 50 条
  • [41] Anesthesia can be safely provided for children in a high-field intraoperative magnetic resonance imaging environment
    Cox, Robin G.
    Levy, Ron
    Hamilton, Mark G.
    Ewen, Alastair
    Farran, Peter
    Neil, Stuart G.
    PEDIATRIC ANESTHESIA, 2011, 21 (04) : 454 - 458
  • [42] High-Field Atherosclerotic Plaque Magnetic Resonance Imaging
    Yuan, Chun
    Wang, Jinnan
    Balu, Niranjan
    NEUROIMAGING CLINICS OF NORTH AMERICA, 2012, 22 (02) : 271 - +
  • [43] Safety aspects in high-field magnetic resonance imaging
    Muehlenweg, M.
    Schaefers, G.
    Trattnig, S.
    RADIOLOGE, 2008, 48 (03): : 258 - 267
  • [44] Superconducting array for high-field magnetic resonance imaging
    Wosik, J.
    Xue, L.
    Xie, L.-M.
    Kamel, M. R.
    Nesteruk, K.
    Bankson, James A.
    APPLIED PHYSICS LETTERS, 2007, 91 (18)
  • [45] Amyloid Imaging Using High-Field Magnetic Resonance
    Amatsubo, Tomone
    Yanagisawa, Daijiro
    Morikawa, Shigehiro
    Taguchi, Hiroyasu
    Tooyama, Ikuo
    MAGNETIC RESONANCE IN MEDICAL SCIENCES, 2010, 9 (03) : 95 - 99
  • [46] Intraoperative Visualization of Residual Tumor: The Role of Perfusion-Weighted Imaging in a High-Field Intraoperative Magnetic Resonance Scanner
    Roder, Constantin
    Bender, Benjamin
    Ritz, Rainer
    Honegger, Juergen
    Feigl, Guenther
    Naegele, Thomas
    Tatagiba, Marcos Soares
    Ernemann, Ulrike
    Bisdas, Sotirios
    NEUROSURGERY, 2013, 72 (06) : 151 - 158
  • [47] Analysis of 137 Patients Who Underwent Endoscopic Transsphenoidal Pituitary Adenoma Resection Under High-Field Intraoperative Magnetic Resonance Imaging Navigation
    Zhang, Huaping
    Wang, Fuyu
    Zhou, Tao
    Wang, Peng
    Chen, Xiaolei
    Zhang, Jiashu
    Zhou, Dingbiao
    WORLD NEUROSURGERY, 2017, 104 : 802 - 815
  • [48] Intraoperative high-field magnetic resonance imaging in transsphenoidal surgery of hormonally inactive pituitary macroadenomas - Comments
    Post, Kalmon D.
    Couldwell, William T.
    Mayberg, Marc R.
    NEUROSURGERY, 2006, 59 (01) : 113 - 114
  • [49] IMPACT OF INTRAOPERATIVE HIGH-FIELD MAGNETIC RESONANCE IMAGING GUIDANCE ON GLIOMA SURGERY: A PROSPECTIVE VOLUMETRIC ANALYSIS
    Hatiboglu, Mustafa Aziz
    Weinberg, Jeffrey S.
    Suki, Dima
    Rao, Ganesh
    Prabhu, Sujit S.
    Shah, Komal
    Jackson, Ed
    Sawaya, Raymond
    NEUROSURGERY, 2009, 64 (06) : 1073 - 1081
  • [50] Use of High-Field Intraoperative Magnetic Resonance Imaging to Enhance the Extent of Resection of Enhancing and Nonenhancing Gliomas
    Mohammadi, Alireza Mohammad
    Sullivan, T. Barrett
    Barnett, Gene H.
    Recinos, Violette
    Angelov, Lilyana
    Kamian, Kambiz
    Vogelbaum, Michael A.
    NEUROSURGERY, 2014, 74 (04) : 339 - 348