Comparative study on long-term stability in mandibular sagittal split ramus osteotomy: hydroxyapatite/poly-L-lactide mesh versus titanium miniplate

被引:11
|
作者
Park, Young-Wook [1 ]
Kang, Hyun-Sik [1 ]
Lee, Jang-Ha [1 ]
机构
[1] Gangneung Wonju Natl Univ, Coll Dent, Dept Oral & Maxillofacial Surg, 7 Jukheon Gil, Kangnung 25457, Gangwon Do, South Korea
关键词
Mandibular SSRO; HA/PLLA mesh; Titanium miniplate; Long-term skeletal stability; BIMAXILLARY ORTHOGNATHIC SURGERY; SKELETAL STABILITY; FORGED COMPOSITES; FIXATION; DEVICES; PLATES;
D O I
10.1186/s40902-019-0192-6
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Background: Resorbable devices have recently been adopted in the field of orthognathic surgery with controversies about their postoperative skeletal stability. Hence, we determined the long-term skeletal stability of unsintered hydroxyapatite/poly-L-lactic acid (HA/PLLA) mesh for osteofixation of mandibular sagittal split ramus osteotomy (SSRO), and compared it with that of titanium miniplate. Methods: Patients were divided into resorbable mesh and titanium miniplate fixation groups. A comparative study of the change in the mandibular position was performed with preoperative, 1-day, 6-month, and 2-year postoperative lateral cephalograms. Results: At postoperative 6 months-compared with postoperative 1 day, point B (supra-mentale) was significantly displaced anteriorly in the titanium-fixation group. Moreover, at postoperative 2 years-compared with postoperative 6 months, point B was significantly displaced inferiorly in the titanium-fixation. However, the HA/PLLA mesh-fixation group did not show any significant change with respect to point B postoperatively. Conclusions: The HA/PLLA mesh-fixation group demonstrated superior long-term skeletal stability with respect to the position of mandible, when compared with the titanium-fixation group.
引用
收藏
页数:6
相关论文
共 43 条
  • [21] Stepwise Advancement Herbst Appliance versus Mandibular Sagittal Split Osteotomy Treatment Effects and Long-term Stability of Adult Class II Patients
    Chaiyongsirisern, A.
    Rabie, A. Bakr
    Wong, Ricky W. K.
    ANGLE ORTHODONTIST, 2009, 79 (06) : 1084 - 1094
  • [22] Long-Term Bioresorption of Bone Fixation Devices Made from Composites of Unsintered Hydroxyapatite Particles and Poly-L-Lactide
    Sukegawa, Shintaro
    Kanno, Takahiro
    Kawai, Hotaka
    Shibata, Akane
    Takahashi, Yuka
    Nagatsuka, Hitoshi
    Furuki, Yoshihiko
    JOURNAL OF HARD TISSUE BIOLOGY, 2015, 24 (02) : 219 - 224
  • [23] Assessment of biomechanical strength of titanium versus unsintered-hydroxyapatite/poly-L-lactic acid (u-HA/PLLA) osteosynthesis screws in bilateral sagittal split ramus osteotomy
    Shijirbold, Ankhtsetseg
    Ramanathan, Mrunalini
    Matsuda, Yuhei
    Sankepally, Nithish
    Fujioka-Kobayashi, Masako
    Kanno, Takahiro
    JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY MEDICINE AND PATHOLOGY, 2025, 37 (03) : 440 - 445
  • [24] Three-Dimensional Analysis of Long-Term Stability After Bilateral Sagittal Split Ramus Osteotomy Fixed With a Single Miniplate With 4 Monocortical Screws and 1 Bicortical Screw: A Retrospective 2-Center Study
    Hernandez-Alfaro, Federico
    Raffaini, Mirco
    Paredes-de-Sousa-Gil, Ariane
    Magri, Alice Sara
    Guijarro-Martinez, Raquel
    Valls-Ontanon, Adaia
    JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 2017, 75 (05) : 1036 - 1045
  • [25] Comparative study of biomechanical stability of resorbable and titanium fixation systems after sagittal split ramus osteotomy with a novel designed in-vitro testing unit
    Ulu, Murat
    Soylu, Emrah
    Kelebek, Seyfi
    Dikici, Serkan
    Oflaz, Hakan
    JOURNAL OF CRANIO-MAXILLOFACIAL SURGERY, 2018, 46 (02) : 299 - 304
  • [26] Biodegradation and strength retention of poly-L-lactide screws in vivo.: An experimental long-term study in sheep
    Jukkala-Partio, K
    Pohjonen, T
    Laitinen, O
    Partio, EK
    Vasenius, J
    Toivonen, T
    Kinnunen, J
    Törmälä, P
    Rokkanen, P
    ANNALES CHIRURGIAE ET GYNAECOLOGIAE, 2001, 90 (03) : 219 - 224
  • [27] Does adjunctive fixation in conjunction with miniplate affect condylar position and morphology after mandibular advancement through bilateral sagittal split ramus osteotomy? A retrospective 3-dimensional CT comparative study
    Al-Watary, Mohammed Qasem
    Telha, Wael Ahmed
    Ge, Han
    Wu, Yifan
    Sun, Xiaoshuang
    Qing, Zhao
    Li, Jihua
    JOURNAL OF CRANIO-MAXILLOFACIAL SURGERY, 2024, 52 (06) : 778 - 785
  • [28] Transmission electron microscopic visualization of the degradation and phagocytosis of a poly-L-lactide screw in cancellous bone:: A long-term experimental study
    Laitinen, O
    Pihlajamäki, H
    Sukura, A
    Böstman, O
    JOURNAL OF BIOMEDICAL MATERIALS RESEARCH, 2002, 61 (01): : 33 - 39
  • [29] A long-term clinical study on drawn poly-L-lactide implants in orthopaedic surgery (vol 7, pg 119, 1997)
    Matsusue, Y
    Nakamura, T
    Iida, H
    Shimizu, K
    JOURNAL OF LONG-TERM EFFECTS OF MEDICAL IMPLANTS, 1997, 7 (3-4) : CP1 - CP1
  • [30] Short- and Long-Term Changes of Condylar Position After Bilateral Sagittal Split Ramus Osteotomy for Mandibular Advancement in Combination With Le Fort I Osteotomy Evaluated by Cone-Beam Computed Tomography
    Chen, Shuo
    Lei, Jie
    Wang, Xing
    Fu, Kai-yuan
    Farzad, Payam
    Yi, Biao
    JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 2013, 71 (11) : 1956 - 1966