A new high-resolution PET scanner dedicated to brain research

被引:48
|
作者
Watanabe, M [1 ]
Shimizu, K [1 ]
Omura, T [1 ]
Takahashi, M [1 ]
Kosugi, T [1 ]
Yoshikawa, E [1 ]
Sato, N [1 ]
Okada, H [1 ]
Yamashita, T [1 ]
机构
[1] Hamamatsu Photon KK, Hamakita 4348601, Japan
关键词
instrumentation; performance measurements; positron emission tomography (PET);
D O I
10.1109/TNS.2002.1039541
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
A high-resolution positron emission tomography (PET) scanner dedicated to brain studies has been developed and its physical performance was evaluated. The block detector consists of a new compact position-sensitive photomultiplier tube (PS-PMT, Hamamatsu R7600-C12) and an 8 x 4 bismuth germanate (BGO) array. The size of each crystal is 2.8 mm x 6.55 mm x 30 mm. The system has a total of 11520 crystals arranged in 24 detector rings 508 mm in diameter (480 per ring). The field of view (FOV) is 330 mm in diameter x 163 mm, which is sufficient to measure the entire human brain. The diameter of the scanner's opening is equal to the transaxial FOV (330 mm). The system can be operated in three-dimensional (3-D) data acquisition mode, when the slice septa are retracted. The mechanical motions of the gantry and bed are specially designed to measure the patient in various postures; lying, sitting, and even standing postures. The spatial resolution of 2.9 mm in both the transaxial and axial directions is obtained at the center of the FOV. The total system sensitivity is 6.4 kc/s/kBq/ml in two-dimensional (2-D) mode, with a 20-cm-diameter cylindrical phantom. The imaging capabilities of the scanner were studied with the Hoffman brain phantom and with a normal volunteer.
引用
收藏
页码:634 / 639
页数:6
相关论文
共 50 条
  • [41] Region of interest specific high-resolution imaging in dedicated brain SPECT
    Kalluri, Kesava
    Mathur, Parth
    Pells, Sophia
    May, Micaehla
    Segars, William
    Lindsay, Clifford
    Kupinski, Matthew
    Furenlid, Lars
    Kuo, Phillip
    King, Michael
    JOURNAL OF NUCLEAR MEDICINE, 2023, 64
  • [42] High-resolution scanner for neuroanatomical analysis
    Krout, KE
    Jenkins, JM
    Loewy, AD
    JOURNAL OF NEUROSCIENCE METHODS, 2002, 113 (01) : 37 - 40
  • [43] Performance of the Sherbrooke avalanche photodiode PET scanner: A new high resolution device for animal research.
    Lecomte, R
    Cadorette, J
    Rodrigue, S
    Rouleau, D
    Yao, R
    JOURNAL OF NUCLEAR MEDICINE, 1996, 37 (05) : 744 - 744
  • [44] Performance Estimation for the High Resolution CaLIPSO Brain PET Scanner: A Simulation Study
    Kochebina, Olga
    Jan, Sebastien
    Stute, Simon
    Sharyy, Viatcheslav
    Verrecchia, Patrice
    Mancardi, Xavier
    Yvon, Dominique
    IEEE TRANSACTIONS ON RADIATION AND PLASMA MEDICAL SCIENCES, 2019, 3 (03) : 363 - 370
  • [45] HIGH-RESOLUTION TUBING WELD SCANNER
    TRBOVICH, T
    BAKER, RA
    JOLLY, WD
    MATERIALS EVALUATION, 1981, 39 (10) : A14 - A14
  • [46] A VERSATILE HIGH-RESOLUTION IMAGE SCANNER
    MCNANEY, JT
    ELECTRO-OPTICAL SYSTEMS DESIGN, 1982, 14 (09): : 47 - &
  • [47] A HIGH-RESOLUTION INTERACTIVE IMAGE SCANNER
    SIMON, W
    BLUMENTHAL, S
    IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1980, 27 (08) : 468 - 472
  • [48] Investigation of a Dedicated, High Resolution PET/CT Scanner for Staging and Treatment Planning of Head and Neck Cancer
    Raylman, Raymond R.
    Stolin, Alexander V.
    Sompalli, Prashanth
    Randall, Nicole Bunda
    Martone, Peter F.
    Clinthorne, Neal H.
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2015, 62 (05) : 2057 - 2066
  • [49] IMPACT OF NEW SCATTER CORRECTION STRATEGIES ON HIGH-RESOLUTION RESEARCH TOMOGRAPH PET STUDIES
    Mansor, M.
    Boellaard, R.
    Huisman, M. C.
    van Berckel, B. N. M.
    Lammertsma, A. A.
    van Velden, F. H. P.
    JOURNAL OF CEREBRAL BLOOD FLOW AND METABOLISM, 2016, 36 : 636 - 637
  • [50] A high-resolution GSO-based brain PET camera
    Karp, JS
    Adam, LE
    Freifelder, R
    Muehllehner, G
    Liu, F
    Surti, S
    1999 IEEE NUCLEAR SCIENCE SYMPOSIUM - CONFERENCE RECORD, VOLS 1-3, 1999, : 1077 - 1081