Silk® Flow Diverter Device for Intracranial Aneurysm Treatment: A Systematic Review and Meta-Analysis

被引:18
|
作者
Florez, William A. [1 ]
Garcia-Ballestas, Ezequiel [1 ,2 ]
Quinones-Ossa, Gabriel Alexander [1 ,3 ]
Janjua, Tariq [4 ]
Konar, Subhas [5 ]
Agrawal, Amit [6 ]
Moscote-Salazar, Luis Rafael [1 ,7 ]
机构
[1] Latin Amer Council Neurocrit Care CLaNi, Cartagena, Colombia
[2] Univ Cartagena, Fac Med, Ctr Biomed Res CIB, Cartagena, Colombia
[3] Univ El Bosque, Fac Med, Bogota, Colombia
[4] Reg Hosp, Dept Neurol & Crit Care, St Paul, MN USA
[5] Natl Inst Mental Hlth & Neurosci, Dept Neurosurg, Bangalore, Karnataka, India
[6] All India Inst Med Sci, Dept Neurosurg, Bhopal, Madhya Pradesh, India
[7] RED LATINO, Latin Amer Org Trauma & Neurocrit Care, Bogota, Colombia
关键词
Aneurysm; Intracranial aneurysm; Neurosurgery; Neurosurgical procedures; Cerebrovascular circulation;
D O I
10.5469/neuroint.2021.00234
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Flow diverters have become a critical instrument for complex aneurysms treatment. However, limited data are currently available regarding short and long-term outcomes for the Silk flow diverter. The objective of the study is to determine neurological prognosis and mortality rates for the Silk flow diversion device used in intracranial aneurysms. A systematic review with meta-analysis was performed using databases. The following descriptors were used for the search: "SILK", "Flow Diverter", "Mortality", and "Prognosis". The following data were extracted: mortality, good functional outcome, Glasgow outcome scale, complete or near-complete occlusion rates, rate of retreatment, and complications (thromboembolic and hemorrhagic complications). A total of 14 studies were selected. Among the 14 studies, 13 were retrospective observational cohort studies and 1 was a prospective observational cohort study. The mortality rate was 2.84%. The clinical good outcomes rate was 93.3%. The poor outcome rate was 6.6%. The overall thromboembolic complication rate was 6.06% (95% confidence interval [CI] 0.00-6.37, P=0.12, I-2=3.13%). The total hemorrhagic complication rate was 1.62% (95% CI 0.00-5.34, P=0.28, I-2=1.56%). The complete aneurysm occlusion rate was 80.4% (95% CI 8.65-9.38, P<0.0001, I-2=9.09%). The Silk diverter device has a good safety and efficacy profile for treating intracranial aneurysms with high complete occlusion rates.
引用
收藏
页码:222 / 231
页数:10
相关论文
共 50 条
  • [31] Intracranial Arterial Fenestration and Risk of Aneurysm: A Systematic Review and Meta-Analysis
    Guo, Xiang
    Gao, Lingyun
    Shi, Zhitao
    Liu, Deguo
    Wang, Yuhong
    Sun, Zhanguo
    Chen, Yueqin
    Chen, Weijian
    Yang, Yunjun
    WORLD NEUROSURGERY, 2018, 115 : E592 - E598
  • [32] Pipeline Vantage Embolization Device for the treatment of intracranial aneurysms: A systematic review and meta-analysis
    Goertz, Lukas
    Hohenstatt, Sophia
    Zopfs, David
    Kottlors, Jonathan
    Pennig, Lenhard
    Schlamann, Marc
    Michael, Arwed Elias
    Liebig, Thomas
    Moehlenbruch, Markus A.
    Kabbasch, Christoph
    INTERVENTIONAL NEURORADIOLOGY, 2024,
  • [33] Hemodynamic Investigation of the Flow Diverter Treatment of Intracranial Aneurysm
    Boniforti, Maria Antonietta
    Magini, Roberto
    Salinas, Tania Orosco
    FLUIDS, 2023, 8 (07)
  • [34] Intracranial Aneurysm Wall Enhancement Associated with Aneurysm Rupture: A Systematic Review and Meta-analysis
    Wang, Xinrui
    Zhu, Chengcheng
    Leng, Yue
    Degnan, Andrew J.
    Lu, Jianping
    ACADEMIC RADIOLOGY, 2019, 26 (05) : 664 - 673
  • [35] SILK flow diverter for treatment of intracranial aneurysms: initial experience and cost analysis
    Shankar, Jai Jai Shiva
    Vandorpe, Robert
    Pickett, Gwynedd
    Maloney, William
    JOURNAL OF NEUROINTERVENTIONAL SURGERY, 2013, 5 : III11 - III15
  • [36] Treatment of Middle Cerebral Artery Aneurysms with Flow-Diverter Stents: A Systematic Review and Meta-Analysis
    Cagnazzo, F.
    Mantilla, D.
    Lefevre, P-H.
    Dargazanli, C.
    Gascou, G.
    Costalat, V.
    AMERICAN JOURNAL OF NEURORADIOLOGY, 2017, 38 (12) : 2289 - 2294
  • [37] Combined balloon plus stent technique for treatment of intracranial aneurysm: a systematic review and meta-analysis
    Habibi, Mohammad Amin
    Arshadi, Mohammad Reza
    Gharedaghi, Hossein
    Rashidi, Farhang
    Asgarzadeh, Ali
    EGYPTIAN JOURNAL OF NEUROSURGERY, 2025, 40 (01)
  • [38] Periprocedural complications of second-generation flow diverter treatment using Pipeline Flex for unruptured intracranial aneurysms: a systematic review and meta-analysis
    Bhatia, Kartik Dev
    Kortman, Hans
    Orru, Emanuele
    Klostranec, Jesse M.
    Pereira, Vitor M.
    Krings, Timo
    JOURNAL OF NEUROINTERVENTIONAL SURGERY, 2019, 11 (08) : 817 - 824
  • [39] Flow diverter retreatment for intracranial aneurysms: A meta-analysis of efficacy and feasibility
    Lee, Irene
    Kao, Yung-Shuo
    Lai, Yen-Jun
    Yen, Ho-Hsian
    INTERVENTIONAL NEURORADIOLOGY, 2024, 30 (01) : 37 - 42
  • [40] Clinical Outcome of Pipeline Embolization Device with and without Coils to Treat Intracranial Aneurysm: A Systematic Review and Meta-Analysis
    Kesumayadi, Irfan
    Sakamoto, Makoto
    Hosoya, Tomohiro
    Kambe, Atsushi
    Uno, Tetsuji
    Yoshioka, Hiroki
    Kurosaki, Masamichi
    AMERICAN JOURNAL OF NEURORADIOLOGY, 2025, 46 (02) : 272 - 277