Impact of gas turbine flexibility improvements on combined cycle gas turbine performance

被引:22
|
作者
Abudu, Kamal [1 ]
Igie, Uyioghosa [1 ]
Roumeliotis, Ioannis [1 ]
Hamilton, Richard [2 ]
机构
[1] Cranfield Univ, Sch Aerosp Transport & Mfg, Cranfield MK43 0AL, Beds, England
[2] Mitsubishi Hitachi Power Syst Europe, 37 North Wharf Rd, London W2 1AF, England
基金
欧盟地平线“2020”;
关键词
Flexibility; Gas turbine; MEL; Ramp-up rate; Power augmentation; AIR ENERGY-STORAGE; INTEGRATION;
D O I
10.1016/j.applthermaleng.2021.116703
中图分类号
O414.1 [热力学];
学科分类号
摘要
The improvement of gas turbines flexibility has been driven by more use of renewable sources of power due to environmental concerns. There are different approaches to improving gas turbine flexibility, and they have performance implications for the bottoming cycle in the combined cycle gas turbine (CCGT) operation. The CCGT configuration is favourable in generating more power output, due to the higher thermal efficiency that is key to the economic viability of electric utility companies. However, the flexibility benefits obtained in the gas turbine is often not translated to the overall CCGT operation. In this study, the flexibility improvements are the minimum environmental load (MEL) and ramp-up rates, that are facilitated by gas turbine compressor air extraction and injection, respectively. The bottoming cycle has been modelled in this study, based on the detailed cascade approach, also using the exhaust gas conditions of the topping cycle model from recent studies of gas turbine flexibility by the authors. At the design full load, the CCGT performance is verified and subsequent off-design cases from the gas turbine air extraction and injection simulations are replicated for the bottoming cycle. The MEL extension on the gas turbine that brings about a reduction in the engine power output results in a higher steam turbine power output due to higher exhaust gas temperature of the former. This curtails the extended MEL of the CCGT to 19% improvement, as opposed to 34% for the stand-alone gas turbine. For the CCGT ramp-up rate improvement with air injection, a 51% increase was attained. This is 3% points lower than the stand-alone gas turbine, arising from the lower steam turbine ramp-up rate. The study has shown that the flexibility improvements in the topping cycle also apply to the overall CCGT, despite constraints from the bottoming cycle.
引用
收藏
页数:14
相关论文
共 50 条
  • [21] Load Regulation Strategies and Performance Analysis of Gas Turbine Combined Cycle
    Zhang Xuelei
    Zhou Lanxin
    2011 INTERNATIONAL CONFERENCE ON MACHINE INTELLIGENCE (ICMI 2011), PT 1, 2011, 3 : 393 - 398
  • [22] Allocating the causes of performance deterioration in combined cycle gas turbine plants
    Mathioudakis, K
    Stamatis, A
    Bonataki, E
    JOURNAL OF ENGINEERING FOR GAS TURBINES AND POWER-TRANSACTIONS OF THE ASME, 2002, 124 (02): : 256 - 262
  • [23] Investigation on performance of cycle combined Brayton and Ambient Pressure Gas Turbine
    Xue, Lichao
    Wang, Wei
    Huang, Zhongyue
    CHALLENGES OF POWER ENGINEERING AND ENVIRONMENT, VOLS 1 AND 2, 2007, : 69 - 72
  • [24] Performance of a novel semiclosed gas-turbine refrigeration combined cycle
    Boza, Joseph J.
    Lear, William E.
    Sherif, S. A.
    JOURNAL OF ENERGY RESOURCES TECHNOLOGY-TRANSACTIONS OF THE ASME, 2008, 130 (02): : 0224011 - 02240111
  • [25] Influence of Precooling Cooling Air on the Performance of a Gas Turbine Combined Cycle
    Kwon, Ik Hwan
    Kang, Do Won
    Kang, Soo Young
    Kim, Tong Seop
    TRANSACTIONS OF THE KOREAN SOCIETY OF MECHANICAL ENGINEERS B, 2012, 36 (02) : 171 - 179
  • [26] ASSESSMENT OF GAS TURBINE AND COMBINED CYCLE POWER PLANT PERFORMANCE DEGRADATION
    Hepperle, Nina
    Therkorn, Dirk
    Schneider, Ernst
    Staudacher, Stephan
    PROCEEDINGS OF THE ASME TURBO EXPO 2011, VOL 4, 2012, : 569 - 577
  • [27] Thermodynamic assessment of impact of inlet air cooling techniques on gas turbine and combined cycle performance
    Mohapatra, Alok Ku
    Sanjay
    ENERGY, 2014, 68 : 191 - 203
  • [28] The impact of variable demand upon the performance of a combined cycle gas turbine (CCGT) power plant
    Bass, Robert J.
    Malalasekera, Weeratunge
    Willmot, Peter
    Versteeg, Henk K.
    ENERGY, 2011, 36 (04) : 1956 - 1965
  • [29] COMPARISON OF THE HTTT REHEAT-GAS-TURBINE COMBINED CYCLE WITH THE HTTT NON-REHEAT GAS-TURBINE COMBINED CYCLE
    RICE, IG
    JENKINS, PE
    JOURNAL OF ENGINEERING FOR POWER-TRANSACTIONS OF THE ASME, 1982, 104 (01): : 129 - 142
  • [30] Cycle optimization and high performance analysis of gas engine-gas turbine combined cycles
    Tsuji, Tadashi
    Proceedings of the ASME Turbo Expo 2005, Vol 5, 2005, : 145 - 152