Mixed-mode reversed phase/positively charged repulsion chromatography for intact protein separation

被引:8
|
作者
Ding, Ling [1 ,2 ]
Guo, Zhimou [1 ]
Hu, Zhuo [1 ]
Liang, Xinmiao [1 ]
机构
[1] Chinese Acad Sci, Dalian Inst Chem Phys, Key Lab Separat Sci Analyt Chem, Dalian 116023, Peoples R China
[2] Univ Chinese Acad Sci, Beijing 100049, Peoples R China
基金
中国国家自然科学基金;
关键词
Mixed-mode stationary phase; Reversed-phase liquid chromaitography; Positively charged repulsion; Intact protein separation; Click chemistry; PERFORMANCE LIQUID-CHROMATOGRAPHY; RECOMBINANT MONOCLONAL-ANTIBODIES; TOP-DOWN PROTEOMICS; STATIONARY PHASES; HORIZONTAL POLYMERIZATION; HYDROPHOBIC INTERACTION; THERAPEUTIC PROTEINS; GRADIENT ELUTION; ION-EXCHANGE; PEPTIDES;
D O I
10.1016/j.jpba.2017.01.004
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A mixed-mode reversed phase/positively charged repulsion stationary phase C8PN composed of octyl and amino group has been developed for separation of intact protein. Before the separation of proteins, a set of probe compounds were employed to evaluate the chromatographic properties of C8PN, demonstrating typical reversed phase/positively charged repulsion interaction on this stationary phase as estimated. Then the new C8PN stationary phase was used to separate a standard protein mixture on the reversed phase mode. Compared with a commercial C4 stationary phase, it showed different selectivity for some proteins. In order to better understand the properties of C8PN, the effect of acetonitrile content was investigated based on retention equation. Higher values of the equation parameters on C8PN demonstrated that the protein retentions were more sensitive to the change of acetonitrile content. Besides, the influences of buffer salt additives on the protein retentions were also studied. The retention factors of the proteins got larger with the increase of buffer salt concentration, which confirmed the positively charged repulsion interaction on the column. Finally, the C8PN was further applied to separate oxidized and reduced- forms of Recombinant Human Growth Hormone. Our study indicated the advantages and application potential of mixed-mode reversed phase/positively charged repulsion stationary phase for intact protein separation. (C) 2017 Elsevier B.V. All rights reserved.
引用
收藏
页码:63 / 69
页数:7
相关论文
共 50 条
  • [41] Preparation of small peptoid-modified zwitterion-exchange/reversed-phase mixed-mode chromatography stationary phases for the separation of arenes and antibiotics
    Xu, Meng
    Wu, Zhenwei
    ANALYTICA CHIMICA ACTA, 2024, 1296
  • [42] Preparation and Evaluation of Poly-l-Lysine Stationary Phase for Hydrophilic Interaction/Reversed-Phase Mixed-Mode Chromatography
    Yuanyuan Li
    Zhigang Xu
    Yaoyao Feng
    Xiaoyan Liu
    Tong Chen
    Haixia Zhang
    Chromatographia, 2011, 74 : 523 - 530
  • [43] Preparation and Evaluation of Poly-L-Lysine Stationary Phase for Hydrophilic Interaction/Reversed-Phase Mixed-Mode Chromatography
    Li, Yuanyuan
    Xu, Zhigang
    Feng, Yaoyao
    Liu, Xiaoyan
    Chen, Tong
    Zhang, Haixia
    CHROMATOGRAPHIA, 2011, 74 (7-8) : 523 - 530
  • [44] USE OF MIXED-MODE, HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY FOR THE SEPARATION OF PEPTIDE AND PROTEIN MIXTURES
    HANCOCK, WS
    SPARROW, JT
    JOURNAL OF CHROMATOGRAPHY, 1981, 206 (01): : 71 - 82
  • [45] SEPARATION OF FATTY-ACID BINDING-PROTEIN BY HIGH-PERFORMANCE MIXED-MODE CHROMATOGRAPHY
    SAMANTA, A
    CORDIS, GA
    PRASAD, MR
    DAS, DK
    JOURNAL OF CHROMATOGRAPHY, 1988, 459 : 221 - 227
  • [46] Multiple heart-cutting mixed-mode chromatography-reversed-phase 2D-liquid chromatography method for separation and mass spectrometric characterization of synthetic oligonucleotides
    Li, Feiyang
    Su, Xiaoli
    Baeurer, Stefanie
    Laemmerhofer, Michael
    JOURNAL OF CHROMATOGRAPHY A, 2020, 1625 (1625)
  • [47] An analytical method for alkaloids of Coptis chinensis based on mixed-mode surface electrostatic exclusion/reversed-phase chromatography
    Zhang Huarong
    Guo Zhimou
    Yu Wei
    Yan Jingyu
    Jin Gaowa
    Wang Lianzhi
    CHINESE JOURNAL OF CHROMATOGRAPHY, 2018, 36 (10) : 1053 - 1060
  • [48] Eluting possibilities with mixed-mode chromatography
    Rios, Maribel
    Pharmaceutical Technology, 2007, 31 (05) : 40 - 48
  • [49] Modeling of mixed-mode chromatography of peptides
    Bernardi, Susanna
    Getaz, David
    Forrer, Nicola
    Morbidelli, Massimo
    JOURNAL OF CHROMATOGRAPHY A, 2013, 1283 : 46 - 52
  • [50] Two-dimensional liquid chromatography separation of peptides using reversed-phase/weak cation-exchange mixed-mode column in first dimension
    Cai, Xiaoming
    Guo, Zhimou
    Xue, Xingya
    Xu, Junyan
    Zhang, Xiuli
    Liang, Xinmiao
    JOURNAL OF CHROMATOGRAPHY A, 2012, 1228 : 242 - 249