Voltage Quality Behaviour of a Wind Turbine Based Remote Area Power System

被引:0
|
作者
Mendis, Nishad [1 ]
Muttaqi, Kashem M. [1 ]
Perera, Sarath [1 ]
机构
[1] Univ Wollongong, Sch Elect Comp Engn & Telecommun Engn, Wollongong, NSW 2522, Australia
关键词
D O I
暂无
中图分类号
TP3 [计算技术、计算机技术];
学科分类号
0812 ;
摘要
The power quality behaviour of a Remote Area Power System (RAPS) consisting of a Doubly Fed Induction Generator (DFIG), its main loads and a dummy load is presented in this paper. The dummy load is used to maintain the power balance of the system under changing wind and loading conditions. The performance of the remote area power system subject to various loading conditions has been evaluated in terms of the voltage quality, an aspect which has not received much attention in the past The existing Distributed Generation (DG) power quality standards are taken as the basis to compare the voltage quality of the simulated waveforms. The simulation results indicate that the system evaluated is able to maintain the load bus bar voltage and frequency within tight limits whereas a better harmonic performance can be achieved if adequate filtering is employed. The model was developed using SimPowerSystem tool box in MATLAB.
引用
收藏
页码:1323 / 1328
页数:6
相关论文
共 50 条
  • [11] Dynamic behaviour of a Francis turbine during voltage regulation in the electrical power system
    Vagnoni, E.
    Valentin, D.
    Avellan, F.
    INTERNATIONAL JOURNAL OF ELECTRICAL POWER & ENERGY SYSTEMS, 2021, 125
  • [12] Adjustable Speed Generation System for Wind Turbine Power Quality Improvement
    Koczara, Wlodzimierz
    Iwanski, Grzegorz
    Chlodnicki, Zdzislaw
    IECON: 2009 35TH ANNUAL CONFERENCE OF IEEE INDUSTRIAL ELECTRONICS, VOLS 1-6, 2009, : 4318 - +
  • [13] Power Quality Enhancement for a Grid Connected Wind Turbine Energy System
    Bubshait, Abdullah S.
    Mortezaei, Ali
    Simoes, Marcelo Godoy
    Busarello, Tiago Davi Curi
    IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS, 2017, 53 (03) : 2495 - 2505
  • [14] Load Frequency Control Design for Two Area Interconnected Power System with DFIG Based Wind Turbine
    Komboigo, Charles
    Urasaki, Naomitsu
    Senju, Tomonobu
    Lotfy, Mohammed Elsayed
    Howlader, Abdul Motin
    Datta, Manoj
    INTERNATIONAL JOURNAL OF EMERGING ELECTRIC POWER SYSTEMS, 2019, 20 (06)
  • [15] δ Index System for Wind Resource Assessment based on Power Characteristics of Wind Turbine
    Liu, Ning (liuning_go@163.com), 1600, Science Press (38):
  • [16] Power Control of DFIG Based Wind Turbine During Stator Voltage Drop
    Lazrak, Ahmed
    Abbou, Ahmed
    Sidki, Mohammed
    PROCEEDINGS OF 2015 3RD IEEE INTERNATIONAL RENEWABLE AND SUSTAINABLE ENERGY CONFERENCE (IRSEC'15), 2015, : 197 - 203
  • [17] Power Quality Analysis And Remote Monitoring System Design of Wind Farms Based on Virtual Instrument
    Liu Hongda
    Ma Zhongli
    Lan Hai
    ICFCSE 2011: 2011 INTERNATIONAL CONFERENCE ON FUTURE COMPUTER SUPPORTED EDUCATION, VOL 1, 2011, : 165 - 168
  • [18] Research of Wind Turbine Based on Power Fuzzy Control System
    Hu, Linjing
    Xi, Dongmin
    Wang, Yonglan
    POWER AND ENERGY ENGINEERING CONFERENCE 2010, 2010, : 111 - 115
  • [19] Measurement of starting characteristics of a remote area Darrieus wind turbine
    Dept. of Electrical Engineering, Monash University, Clayton, Vic. 3168, Australia
    不详
    不详
    Wind Eng., 6 (365-372):
  • [20] Research and design of the remote monitoring system for power quality in wind farms
    He, Qun
    Jiang, Guo Qian
    Yu, Zi Kou
    Xie, Ping
    INFORMATION TECHNOLOGY APPLICATIONS IN INDUSTRY, PTS 1-4, 2013, 263-266 : 387 - 391