摘要
The power quality behaviour of a Remote Area Power System (RAPS) consisting of a Doubly Fed Induction Generator (DFIG), its main loads and a dummy load is presented in this paper. The dummy load is used to maintain the power balance of the system under changing wind and loading conditions. The performance of the remote area power system subject to various loading conditions has been evaluated in terms of the voltage quality, an aspect which has not received much attention in the past The existing Distributed Generation (DG) power quality standards are taken as the basis to compare the voltage quality of the simulated waveforms. The simulation results indicate that the system evaluated is able to maintain the load bus bar voltage and frequency within tight limits whereas a better harmonic performance can be achieved if adequate filtering is employed. The model was developed using SimPowerSystem tool box in MATLAB.
引用
收藏
页码:1323 / 1328
页数:6
相关论文
共 50 条
  • [1] Enhanced Reactive Power Support of a PMSG based Wind Turbine for a Remote Area Power System
    Sayeef, Saad
    Mendis, Nishad
    Muttaqi, Kashem
    Perera, Sarath
    2010 20TH AUSTRALASIAN UNIVERSITIES POWER ENGINEERING CONFERENCE (AUPEC 2010): POWER QUALITY FOR THE 21ST CENTURY, 2010,
  • [2] Reactive Power Voltage Stability Control of Power System with Wind Turbine Based on STATCOM
    Yao, Yan
    Gao, Feiling
    Zhou, Ziwang
    2022 6TH INTERNATIONAL CONFERENCE ON POWER AND ENERGY ENGINEERING, ICPEE, 2022, : 31 - 36
  • [3] Wind Turbine Effects on Power System Voltage Fluctuations
    Erduman, A.
    Kilickiran, H. C.
    Kekezoglu, B.
    Durusu, A.
    Tanrioven, M.
    2013 3RD INTERNATIONAL CONFERENCE ON ELECTRIC POWER AND ENERGY CONVERSION SYSTEMS (EPECS), 2013,
  • [4] Active power filter based on wind turbine for electric power system quality improvement
    Rekik, Mouna
    Krichen, Lotfi
    2014 11TH INTERNATIONAL MULTI-CONFERENCE ON SYSTEMS, SIGNALS & DEVICES (SSD), 2014,
  • [5] Control Coordination of a Wind Turbine Generator and a Battery Storage Unit in a Remote Area Power Supply System
    Mendis, Nishad
    Muttaqi, Kashem M.
    Sayeef, S.
    Perera, Sarath
    IEEE POWER AND ENERGY SOCIETY GENERAL MEETING 2010, 2010,
  • [6] A Control Approach for Voltage and Frequency Regulation of a Wind-Diesel-Battery based Hybrid Remote Area Power Supply System
    Mendis, Nishad
    Muttaqi, Kashem M.
    Sayeef, Saad
    Perera, Sarath
    IECON 2010 - 36TH ANNUAL CONFERENCE ON IEEE INDUSTRIAL ELECTRONICS SOCIETY, 2010,
  • [7] POWER QUALITY AND POWER PERFORMANCE MEASUREMENT SYSTEM FOR WIND TURBINE CERTIFICATION
    Martins, Matheus
    Carnielutti, Fernanda
    Pinheiro, Humberto
    2009 BRAZILIAN POWER ELECTRONICS CONFERENCE, VOLS 1 AND 2, 2009, : 734 - 740
  • [8] Reduction of Voltage Violations at Remote Location by Intelligent Active and Reactive Power Control of a DFIG Based Wind Turbine
    da Costa, Jean Patric
    Zacharias, Peter
    Gafaro, Francisco
    PROCEEDINGS OF THE 2011-14TH EUROPEAN CONFERENCE ON POWER ELECTRONICS AND APPLICATIONS (EPE 2011), 2011,
  • [9] Voltage Fluctuations in a Remote Wind-Diesel Hybrid Power System
    Islam, Sheikh Mominul
    Iqbal, M. Tariq
    Quaicoe, John E.
    PROCEEDINGS OF ICECE 2008, VOLS 1 AND 2, 2008, : 699 - 705
  • [10] Dynamic response of a remote area power system to fluctuating wind speed
    Sharma, H
    Islam, S
    Nayar, CV
    Pryor, T
    2000 IEEE POWER ENGINEERING SOCIETY WINTER MEETING - VOLS 1-4, CONFERENCE PROCEEDINGS, 2000, : 499 - 504