Equivalent Circuit of Distribution Line for Lightning-Induced Voltage Analysis Using Analytical Formulas

被引:0
|
作者
Sekioka, Shozo [1 ]
机构
[1] Shonan Inst Technol, Dept Elect & Elect Engn, Fujisawa, Kanagawa, Japan
关键词
lightning surge; lightning-induced voltage; lightning protection design; distribution line; EMTP; ELECTROMAGNETIC-FIELD;
D O I
10.1002/eej.22959
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
This paper proposes an equivalent circuit at a transition point of distribution line for lightning-induced voltage analysis. The lightning-induced voltages caused by a piecewise linearly varying lightning current are expressed by analytical formulas. The equivalent circuit is represented by resistors and current sources, which are known from past history and given by the lightning-induced voltage on an infinite-length line. Transient voltages and currents at the transition point are accurately obtained in small computation time using the equivalent circuit. Thus, the proposed equivalent circuit is very convenient for analyzing the lightning-induced effect in complicated electric power networks. This paper presents an example of EMTP data cards to use the proposed equivalent circuit in the EMTP.
引用
收藏
页码:26 / 34
页数:9
相关论文
共 50 条
  • [41] Lightning-Induced Voltages on Distribution Lines with Shield Wires
    Piantini, Alexandre
    2016 33RD INTERNATIONAL CONFERENCE ON LIGHTNING PROTECTION (ICLP), 2016,
  • [42] Survey on analytical and numerical methods for lightning-induced voltages calculations
    Silva Alves, Adriany Fabricia
    Araujo, Marcel Ayres
    ELECTRICAL ENGINEERING, 2024, 106 (01) : 905 - 916
  • [43] Analysis of lightning-induced forest fires in Austria
    Mueller, Mortimer M.
    Vacik, Harald
    Diendorfer, Gerhard
    Arpaci, Alexander
    Formayer, Herbert
    Gossow, Hartmut
    THEORETICAL AND APPLIED CLIMATOLOGY, 2013, 111 (1-2) : 183 - 193
  • [44] FIELD MEASUREMENTS OF LIGHTNING-INDUCED VOLTAGE TRANSIENTS IN PV ARRAYS
    Vangala, P.
    Ropp, M.
    Haggerty, K.
    Lynn, K.
    Wilson, W.
    PVSC: 2008 33RD IEEE PHOTOVOLTAIC SPECIALISTS CONFERENCE, VOLS 1-4, 2008, : 2116 - +
  • [45] 3-D FDTD Analysis of Lightning-Induced Voltages in Distribution Lines Due to Inclined Lightning
    Natsui, Masashi
    Ametani, Akihiro
    Mahseredjian, Jean
    Sekioka, Shozo
    Yamamoto, Kazuo
    2021 IEEE POWER & ENERGY SOCIETY GENERAL MEETING (PESGM), 2021,
  • [46] Analysis of Lightning-Induced Overvoltage Waveform Parameters
    Wang, She
    Xie, Shijun
    Zhuang, Chijie
    Ouyang, Yong
    Geng, Yinan
    Zeng, Rong
    Liu, Gang
    Cai, Hansheng
    Li, Te
    2018 34TH INTERNATIONAL CONFERENCE ON LIGHTNING PROTECTION (ICLP 2018), 2018,
  • [47] On the use of Homogeneous Ground Model for Lightning-Induced Voltage Calculation
    Paulino, Jose Osvaldo S.
    Boaventura, Wallace do C.
    Lopes, Ivan Jose da S.
    Barbosa, Celio Fonseca
    2015 INTERNATIONAL SYMPOSIUM ON LIGHTNING PROTECTION (XIII SIPDA), 2015, : 191 - 196
  • [48] Statistical Assessment of Lightning-Induced Overvoltages in Low Voltage Lines
    Napolitano, F.
    Tossani, F.
    Penaloza, J. D. R.
    Borghetti, A.
    Lo Piparo, G.
    Mazzetti, C.
    Nucci, C. A.
    2018 IEEE INTERNATIONAL CONFERENCE ON ENVIRONMENT AND ELECTRICAL ENGINEERING AND 2018 IEEE INDUSTRIAL AND COMMERCIAL POWER SYSTEMS EUROPE (EEEIC / I&CPS EUROPE), 2018,
  • [49] Observation of Natural Lightning-Induced Voltage on Overhead Power Lines
    Cai, Li
    Wang, Jianguo
    Zhou, Mi
    Chen, Shaodong
    Xue, Jian
    IEEE TRANSACTIONS ON POWER DELIVERY, 2012, 27 (04) : 2350 - 2359
  • [50] Evaluation of the extended modal-domain model in the calculation of lightning-induced voltages on parallel and double-circuit distribution line configurations
    Leal, Osis E. S.
    De Conti, Alberto
    ELECTRIC POWER SYSTEMS RESEARCH, 2021, 194