Oil flooded compression cycle enhancement for two-stage heat pump in cold climate region: System design and theoretical analysis

被引:16
|
作者
Luo, Baojun [1 ]
机构
[1] Hunan Univ, Coll Mech & Vehicle Engn, Changsha 410082, Hunan, Peoples R China
关键词
Heat pump; Vapor injection; Oil flooding; Flooded compression; Cold climate; R32; SCROLL COMPRESSOR; PERFORMANCE; R410A; OPTIMIZATION; REGENERATION;
D O I
10.1016/j.enconman.2016.02.050
中图分类号
O414.1 [热力学];
学科分类号
摘要
In order to improve the performance of air source heat pump in cold climate region, a combined oil flooded compression with regenerator and vapor injection cycle system is suggested in this paper, which integrates oil flooded compression with regenerator into a conventional vapor injection cycle. A mathematical model is developed and parametric studies on this cycle are conducted to evaluate the benefits of the novel system. The performances of the novel system using R410A and R32 are compared with those of vapor injection cycle system. The improvement of coefficient of performance (COP) can reach up to nearly 9% based on the same isentropic efficiency, while 17.2% based on assumption that there is a 10% rise in isentropic efficiency brought by oil flooded compression cycle. The heating capacity is reduced by 8-18% based on the same volumetric efficiency, while could be less than 10% in a practical system. The discharge temperature is largely decreased and can be below 100 degrees C at -40 degrees C T-e and 50 degrees C T-c condition for R32. The theoretical results demonstrate this novel heat pump has a high potential for improving the performance of air source heat pump in cold climate region. (C) 2016 Elsevier Ltd. All rights reserved.
引用
收藏
页码:52 / 59
页数:8
相关论文
共 50 条
  • [41] Energy consumption simulation and analysis of the two-stage centrifugal vapor-compression water source heat pump
    Jin, Quan
    Shu, Haiwen
    Lin Duanmu
    FIRST INTERNATIONAL CONFERENCE ON BUILDING ENERGY AND ENVIRONMENT, PROCEEDINGS VOLS 1-3, 2008, : 152 - 159
  • [42] Performance Analysis of High-temperature Two-stage Compression Heat Pump with Vapor Injection Dynamic Control
    Luo, Win-Jet
    Lai, Jin-Chang
    Hsieh, Ming-Chu
    Huang, I-Hsing
    SENSORS AND MATERIALS, 2020, 32 (12) : 4259 - 4275
  • [43] Comparison of CO2 transcritical cycle in water source heat pump two-stage heating system
    Ma, Yitai
    Li, Minxia
    Wang, Jinggang
    Lu, Wei
    Nuantong Kongtiao/HV & AC, 2002, 32 (06):
  • [44] Studies on a two-stage transcritical carbon dioxide heat pump cycle with flash intercooling
    Agrawal, Neeraj
    Bhattacharyya, Souvik
    APPLIED THERMAL ENGINEERING, 2007, 27 (2-3) : 299 - 305
  • [45] Analysis of heat pump operated two-stage humidification-dehumidification desalination system with subcooler and heat regenerator
    Wang, Bingdong
    Shen, Jiubing
    Zhu, Wenting
    Wang, Wenhuan
    DESALINATION, 2024, 581
  • [46] Preliminary theoretical analyses of thermal performance and available energy consumption of two-stage cascade cycle heat pump water heater
    Wang, Gang
    Chen, Zeshao
    Li, Chuan
    Jiang, Bin
    INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2017, 82 : 381 - 388
  • [47] Design and rating of a two-stage vapor-compression refrigeration system
    Khan, JUR
    Zubair, SM
    ENERGY, 1998, 23 (10) : 867 - 878
  • [49] Experimental study on two-stage compression refrigeration/heat pump system with dual-cylinder rolling piston compressor
    Xu Shuxue
    Ma Guoyuan
    APPLIED THERMAL ENGINEERING, 2014, 62 (02) : 803 - 808