Partial discharge characteristics of long-term operated 550kV GCB epoxy Spacer

被引:0
|
作者
Watanabe, S [1 ]
Hayakawa, N [1 ]
Kumai, T [1 ]
Okubo, H [1 ]
机构
[1] Nagoya Univ, Nagoya, Aichi, Japan
关键词
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
We developed partial discharge current pulse waveform analysis (PD-CPWA) method in order to estimate insulation degradation of solid insulators. Focusing on the time transition of sequential PD pulses from their inception to breakdown (BD), PD-CPWA was applied to epoxy samples cut from an actual 550kV GCB spacer which had been used in a substation for 25 years. PD parameters such as peak value I, rise time tr, di/dt in a single PD current pulse waveform and time interval Deltat of sequential PD pulses were analyzed. Experimental results revealed that PD generation until BD was not continuous, but disappeared frequently. tr increased drastically and Deltat shorter than 1 msec appeared at about 0.4 sec before BD, which might be prediction parameters of BD.
引用
收藏
页码:462 / 465
页数:4
相关论文
共 41 条
  • [21] Early Supported Discharge for Stroke Patients in Singapore: Patients Characteristics, Clinical Progress and Long-term Outcome
    Yong, J. Q.
    Lim, L. X. M.
    Ong, S. S.
    Yeh, I. L.
    Ling, A. M. W.
    Liang, Y. J.
    Kee, F. H. W.
    Chan, B. P. L.
    CEREBROVASCULAR DISEASES, 2013, 35 : 588 - 588
  • [22] Long-term partial nitritation and microbial characteristics in treating low C/N ratio domestic wastewater
    Wang, Bo
    Zhao, Mengyue
    Guo, Yuanyuan
    Peng, Yongzhen
    Yuan, Yue
    ENVIRONMENTAL SCIENCE-WATER RESEARCH & TECHNOLOGY, 2018, 4 (06) : 820 - 827
  • [23] Long-term ageing characteristics of cemented paste backfill: Usability of sand as a partial substitute of hazardous tailings
    Sari, Muhammet
    Yilmaz, Erol
    Kasap, Tugrul
    JOURNAL OF CLEANER PRODUCTION, 2023, 401
  • [24] Long-term investigations of partial discharge and gassing behavior of ester-based insulating oils for a heated oil gap
    Rumpelt, Patrick
    Fritsche, Ronny
    Bakija, Beriz
    Jenau, Frank
    2017 52ND INTERNATIONAL UNIVERSITIES POWER ENGINEERING CONFERENCE (UPEC), 2017,
  • [25] Does Glomerular Filtration Rate at Discharge After Partial Nephrectomy Predict Long-Term Glomerular Filtration Rate Stability?
    Bernstein, Ari
    Barry, Emily
    Fram, Ethan B.
    Sankin, Alexander
    Kovac, Evan
    Stern, Joshua M.
    JOURNAL OF ENDOUROLOGY, 2019, 33 (06) : 488 - 491
  • [26] Motor Unit Discharge Characteristics and Conduction Velocity of the Vastii Muscles in Long-Term Resistance-Trained Men
    Skarabot, Jakob
    Folland, Jonathan P.
    Forsyth, Jules
    Vazoukis, Apostolos
    Holobar, Ales
    Del Vecchio, Alessandro
    MEDICINE & SCIENCE IN SPORTS & EXERCISE, 2023, 55 (05) : 824 - 836
  • [27] LONG-TERM DISCHARGE CHARACTERISTICS OF LITHIUM-IODINE CELLS WITH AN ADDITIVE IN POLY(2-VINYLPYRIDINE) IODIDE
    LIN, ML
    JIN, YX
    ZHANG, YZ
    HOU, YF
    WANG, SD
    JOURNAL OF POWER SOURCES, 1987, 20 (1-2) : 141 - 143
  • [28] Considerations on the Long-term Reliability of On-line Partial Discharge Ceramic Sensor for Thermal Power Generators and its Demonstration in the Field
    Sun, Jong-Ho
    Youn, Young-Woo
    Hwang, Don-Ha
    Kang, Dong-Sik
    JOURNAL OF ELECTRICAL ENGINEERING & TECHNOLOGY, 2012, 7 (01) : 103 - 108
  • [29] Effects of MgO Nanocrystal Powder on Long-Term Sustain and Address Discharge Characteristics in ac-Plasma Display Panel
    Kim, Jae Hyun
    Park, Choon-Sang
    Dal Park, Hyung
    Shin, Bhum Jae
    Tae, Heung-Sik
    JOURNAL OF NANOSCIENCE AND NANOTECHNOLOGY, 2017, 17 (01) : 335 - 340
  • [30] LONG-TERM DISCHARGE CHARACTERISTICS OF LITHIUM-IODINE CELLS WITH AN ADDITIVE IN POLY(2-VINYLPYRIDINE) IODIDE.
    Lin, Min-Liang
    Jin, Ye-Xian
    Zhang, Yong-Zhen
    Hou, Yu-Feng
    Wang, Shi-Da
    1600, (20): : 1 - 2