Partial discharge characteristics of long-term operated 550kV GCB epoxy Spacer

被引:0
|
作者
Watanabe, S [1 ]
Hayakawa, N [1 ]
Kumai, T [1 ]
Okubo, H [1 ]
机构
[1] Nagoya Univ, Nagoya, Aichi, Japan
关键词
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
We developed partial discharge current pulse waveform analysis (PD-CPWA) method in order to estimate insulation degradation of solid insulators. Focusing on the time transition of sequential PD pulses from their inception to breakdown (BD), PD-CPWA was applied to epoxy samples cut from an actual 550kV GCB spacer which had been used in a substation for 25 years. PD parameters such as peak value I, rise time tr, di/dt in a single PD current pulse waveform and time interval Deltat of sequential PD pulses were analyzed. Experimental results revealed that PD generation until BD was not continuous, but disappeared frequently. tr increased drastically and Deltat shorter than 1 msec appeared at about 0.4 sec before BD, which might be prediction parameters of BD.
引用
收藏
页码:462 / 465
页数:4
相关论文
共 41 条
  • [1] Application of optical partial discharge detection technology in 550kV GIS
    Zhou, Mingyu
    Huang, Yanqing
    Fechner, Tobias
    Luo, Yi
    Wang, Haitian
    Xu, Ruoyu
    2024 IEEE INTERNATIONAL CONFERENCE ON HIGH VOLTAGE ENGINEERING AND APPLICATIONS, ICHVE 2024, 2024,
  • [2] DEVELOPMENT OF 550KV GAS SPACER CABLE .2. VOLTAGE CHARACTERISTICS AND CONSTRUCTION
    TAKAGI, T
    HAYASHI, H
    DOHMAE, Y
    HIGASHINO, T
    ITAKA, K
    ARAKI, T
    KUSAKABE, E
    MORITA, M
    HATA, H
    IEEE TRANSACTIONS ON POWER APPARATUS AND SYSTEMS, 1978, 97 (05): : 1740 - 1748
  • [3] Detection and Diagnosis of Multiple-void Discharge Sources in On-site 550kV GIS Insulating Spacer
    Shao Xianjun
    Li Feiran
    Chen Xiaoxin
    Wang Ziling
    Mei Bingxiao
    He Wenlin
    2019 2ND INTERNATIONAL CONFERENCE ON ELECTRICAL MATERIALS AND POWER EQUIPMENT (ICEMPE 2019), 2019, : 605 - 610
  • [4] Long-Term Partial Discharge Characteristics till Breakdown in a 22 kV Cast Resin Transformer
    Miyagawa, Mizuki
    Yao, Yuanhang
    Koresawa, Ryota
    Kawano, Hideaki
    Hikita, Masayuki
    Kozako, Masahiro
    Takei, Katsutoshi
    Shibata, Teruo
    Uzuki, Tamotsu
    Futakawa, Kazuhiro
    Ozeki, Hiroyuki
    Proceedings of the International Symposium on Electrical Insulating Materials, 2023, : 207 - 210
  • [5] Long-Term AC Partial Discharge Characteristics Till Dielectric Breakdown in an Aged 22 kV Cast Resin Transformer
    Miyagawa, Mizuki
    Yao, Yuanhang
    Kawano, Hideaki
    Hikita, Masayuki
    Kozako, Masahiro
    Harada, Yoshihiro
    Takei, Katsutoshi
    Ikeda, Masaru
    Miyazaki, Kazunori
    Futakawa, Kazuhiro
    IEEE TRANSACTIONS ON DIELECTRICS AND ELECTRICAL INSULATION, 2024, 31 (06) : 3462 - 3468
  • [6] Study on the characteristics of long-term discharge of a catchment
    Hong, Lin
    Takase, Keiji
    Sato, Koichi
    Journal of Hydrodynamics, 2000, 12 (02) : 31 - 41
  • [7] Long-term sequential characteristics of negative partial discharge in pressurized SF6 gas
    Takahashi, T
    Fréchette, MF
    Larocque, RY
    Hudon, C
    Umemura, T
    Matsumoto, S
    Okubo, H
    GASEOUS DIELECTRICS IX, 2001, : 205 - 210
  • [9] Long-Term Partial Discharge Behavior of Protrusion Defect in HVDC GIS
    Vu-Cong, Thanh
    Toigo, Caterina
    Jacquier, Frank
    Girodet, Alain
    Tuczek, Maximilian Nikolaus
    Riechert, Uwe
    Mor, Armando Rodrigo
    IEEE TRANSACTIONS ON DIELECTRICS AND ELECTRICAL INSULATION, 2022, 29 (06) : 2294 - 2302
  • [10] Long-term Online Partial Discharge Trend Monitoring for Cast Resin Transformers in Switchboard
    Kakimoto, Yasutomo
    Jogo, Tatsuki
    Kozako, Masahiro
    Hikita, Masayuki
    Sato, Masaharu
    Abe, Hiroyuki
    Hirokawa, Mitsuharu
    Sato, Hideaki
    2020 8TH INTERNATIONAL CONFERENCE ON CONDITION MONITORING AND DIAGNOSIS (CMD 2020), 2020, : 133 - 135