Device for online monitoring of insulation faults in high-voltage switchgears

被引:8
|
作者
Song, Jiajia [1 ,2 ]
Zhang, Jinbo [1 ,2 ]
Fan, Xinnan [1 ,2 ]
机构
[1] Hohai Univ, Coll IoT Engn, Changzhou 213022, Jiangsu, Peoples R China
[2] Jiangsu Key Lab Power Transmiss & Distribut Equip, Changzhou, Jiangsu, Peoples R China
关键词
Partial discharge; pulse current method; O-3; detection;
D O I
10.1177/1550147721999284
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
Partial discharges are the major cause of deterioration in the insulation characteristics of switchgears. Therefore, timely detection of partial discharge in switchgear and potential insulation faults is an urgent problem that needs to be addressed in the power supervision industry. In this study, a device was proposed for online monitoring of high-voltage switchgears based on pulse current method and ozone (O-3) detection. The pulse current method obtains the PD signal by monitoring the phase holes on the switch indicator. Occurrence of a partial discharge in a certain phase leads to the production of a discharge pulse, which can be coupled out by a capacitive sensor. The current spectrum and the O-3 produced by partial discharge were processed via fast Fourier transform for accurate diagnosis of the occurrence of partial discharge and its severity in switchgears. The proposed method allows for convenient acquisition of the partial discharge signal, simple installation of the device, and realization with inexpensive sensors.
引用
收藏
页数:11
相关论文
共 50 条
  • [21] Polymer Nanocomposites in High-Voltage Insulation
    Chi, Xiaohong
    Wang, Weiwang
    Li, Shengtao
    Frechette, Michel
    Zhang, Xiaohong
    IEEE NANOTECHNOLOGY MAGAZINE, 2018, 12 (02) : 33 - 40
  • [22] Development of Insulation Systems for High-Voltage Busbars with Solid Insulation
    Kovalev D.I.
    Varivodov V.N.
    Golubev D.V.
    Mirzabekyan G.Z.
    Kovalev, D.I. (journal-elektrotechnika@mail.ru), 1600, Pleiades journals (92): : 185 - 192
  • [23] INVESTIGATION OF LOSSES IN INSULATION OF HIGH-VOLTAGE CABLES WITH XLPE INSULATION
    Shchebeniuk, L. A.
    Antonets, T. Yu.
    ELECTRICAL ENGINEERING & ELECTROMECHANICS, 2016, (04) : 58 - 62
  • [24] Research on an Online Monitoring and Diagnosis System of High-voltage Circuit Breaker
    Ni, Pinghao
    Wang, Wei
    POWER AND ENERGY SYSTEMS III, 2014, 492 : 212 - 217
  • [25] High-voltage circuit breaker online monitoring and fault diagnosis technology
    Niu, Weihua
    Zhang, Jing
    ENERGY SCIENCE AND APPLIED TECHNOLOGY (ESAT 2016), 2016, : 665 - 667
  • [26] High-voltage insulation with enhanced delamination resistance
    Schlögl, S.
    Lenko, D.
    Gummi, Fasern, Kunststoffe, 2015, 68 (02): : 108 - 109
  • [27] HIGH-VOLTAGE GLYCERIN-FILM INSULATION
    KOVSHAROV, NF
    FEDUSHCHAK, VF
    INSTRUMENTS AND EXPERIMENTAL TECHNIQUES, 1984, 27 (03) : 764 - 765
  • [28] A HIGH-VOLTAGE TEST GENERATOR FOR INSULATION TESTING
    ELLISON, DH
    EXON, JLT
    BRYAN, AB
    JOURNAL OF PHYSICS E-SCIENTIFIC INSTRUMENTS, 1983, 16 (11): : 1046 - 1051
  • [29] HIGH-VOLTAGE INSULATION OF BINARY CURRENT LEADS
    GERHOLD, J
    CRYOGENICS, 1994, 34 : 623 - 626
  • [30] Alumina based ceramics for high-voltage insulation
    Touzin, M.
    Goeuriot, D.
    Guerret-Piecourt, C.
    Juve, D.
    Fitting, H-J
    JOURNAL OF THE EUROPEAN CERAMIC SOCIETY, 2010, 30 (04) : 805 - 817