Can lithium disilicate ceramic crowns be fabricated on the basis of CBCT data?

被引:13
|
作者
Kauling, Ana Elisa Colle [1 ]
Keul, Christine [1 ]
Erdelt, Kurt [1 ]
Kuehnisch, Jan [2 ]
Gueth, Jan-Frederik [1 ,3 ]
机构
[1] LMU, Univ Hosp, Dept Prosthodont, Munich, Germany
[2] LMU, Univ Hosp, Dept Operat Dent & Periodontol, Munich, Germany
[3] LMU, Univ Hosp, Dept Prosthodont, Munich, Germany
关键词
Cone-beam computed tomography; Digital impression; Direct digitalization; Fit; Indirect restorations; FIXED DENTAL PROSTHESES; IN-VIVO PRECISION; MARGINAL FIT; DIGITAL METHODS; ACCURACY; IMPRESSIONS; TOMOGRAPHY; ZIRCONIA; RESTORATIONS; SIMULATION;
D O I
10.1007/s00784-019-02802-6
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Objectives Evaluating the fit of CAD/CAM lithium disilicate ceramic crowns fabricated on basis of direct and indirect digitalization of impressions by CBCT or of dental casts. Material and methods A metal model with a molar chamfer preparation was digitized (n = 12 per group) in four ways: IOS-direct digitalization using an Intra-Oral scanner (CS3600), cone-beam computed tomography scan (CBCT 1)-indirect digitalization of impression (CBCT-CS9300), CBCT 2-indirect digitalization of impression (CBCT-CS8100), and Extra-Oral scanner (EOS)-indirect digitalization of gypsum-cast (CeramillMap400). Accuracy of 3D datasets was evaluated in relation to a reference dataset by best-fit superimposition. Marginal fit of lithium disilicate crowns after grinding was evaluated by replica technique. Significant differences were detected for 3D accuracy by Mann-Whitney U and for fit of crowns by One-way ANOVA followed by Scheffe's post hoc (p = 0.05). Results 3D analysis revealed mean positive and negative deviations for the groups IOS (- 0.011 +/- 0.007 mm/0.010 +/- 0.003 mm), CBCT 1 (- 0.046 +/- 0.008 mm/0.093 +/- 0.004 mm), CBCT 2 (- 0.049 +/- 0.030 mm/0.072 +/- 0.015 mm), and EOS (- 0.023 +/- 0.007 mm/0.028 +/- 0.007 mm). Marginal fit presented the results IOS (0.056 +/- 0.022 mm), CBCT 1 (0.096 +/- 0.034 mm), CBCT 2 (0.068 +/- 0,026 mm), and EOS (0.051 +/- 0.017 mm). Conclusions The marginal fit of EOS and IOS, IOS and CBCT 2, and CBCT 2 and CBCT 1 showed statistical differences. The marginal fit of CBCT 1 and CBCT 2 is within the range of clinical acceptance; however, it is significant inferior to EOS and IOS.
引用
收藏
页码:3739 / 3748
页数:10
相关论文
共 50 条
  • [21] Influence of the Application and Light-Curing of Bonding Adhesives Inside Lithium Disilicate Ceramic Crowns
    Maluly-Proni, Ana Teresa
    Oliveira-Reis, Bruna
    Jardim, Vitor Ribeiro
    Vasconcelos, Getulio
    Assuncao, Wirley Goncalves
    dos Santos, Paulo Henrique
    EUROPEAN JOURNAL OF PROSTHODONTICS AND RESTORATIVE DENTISTRY, 2020, 28 (02): : 65 - 74
  • [22] Clinical Outcomes and Predictors of Satisfaction in Patients with Improved Lithium Disilicate All-Ceramic Crowns
    Samer, Mazin Saleh
    Faraz, Qahtani
    Al-Dubai, Sami Abdo Radman
    Vohra, Fahim
    Abdullah, Hadijah
    Taiyeb-Ali, Tara Bai
    Saub, Roslan
    MEDICAL PRINCIPLES AND PRACTICE, 2017, 26 (05) : 470 - 479
  • [23] GLASS-CERAMIC MATERIALS ON THE LITHIUM DISILICATE BASIS: ACHIEVEMENTS AND DEVELOPMENT PROSPECTS
    Savvova, Oksana
    Voronov, Gennadii
    Topchyi, Vitalii
    Smyrnova, Yuliya
    CHEMISTRY & CHEMICAL TECHNOLOGY, 2018, 12 (03): : 391 - 399
  • [24] Clinical evaluation of the fit of lithium disilicate crowns fabricated with three different CAD-CAM systems
    Ahn, Jong-Ju
    Bae, Eun-Bin
    Lee, Jin-Ju
    Choi, Jae-Won
    Jeon, Young-Chan
    Jeong, Chang-Mo
    Yun, Mi-Jung
    Lee, So-Hyoun
    Lee, Kyu-Bok
    Huh, Jung-Bo
    JOURNAL OF PROSTHETIC DENTISTRY, 2022, 127 (02): : 239 - 247
  • [25] Comparison of Intaglio Surface Adjustment in the Oral Cavity for Lithium Disilicate Crowns Fabricated Using Different Scanners
    Son, Keunbada
    Yu, Beom-Young
    Lee, Jeong-Hyeon
    Son, Young-Tak
    Lee, Kyu-Bok
    JOURNAL OF PROSTHODONTICS-IMPLANT ESTHETIC AND RECONSTRUCTIVE DENTISTRY, 2021, 30 (03): : 276 - 281
  • [26] Comparative Study of the Trueness of the Inner Surface of Crowns Fabricated from Three Types of Lithium Disilicate Blocks
    Son, Keunbada
    Yu, Beom-young
    Yoon, Tae Ho
    Lee, Kyu-bok
    APPLIED SCIENCES-BASEL, 2019, 9 (09):
  • [27] Fit of lithium disilicate crowns fabricated from conventional and digital impressions assessed with micro-CT
    Kim, Jae-Hyun
    Jeong, Ji-Hye
    Lee, Jin-Han
    Cho, Hye-Won
    JOURNAL OF PROSTHETIC DENTISTRY, 2016, 116 (04): : 551 - 557
  • [28] The Structural Integrity and Fracture Behaviour of Teeth Restored with PEEK and Lithium-Disilicate Glass Ceramic Crowns
    Aldhuwayhi, Sami
    Alauddin, Muhammad Syafiq
    Martin, Nicolas
    POLYMERS, 2022, 14 (05)
  • [29] Influence of veneer pore defects on fracture behavior of bilayered lithium disilicate glass-ceramic crowns
    Jian, Yutao
    Dao, Li
    Wang, Xiaodong
    Zhang, Xinping
    Swain, Michael, V
    Zhao, Ke
    DENTAL MATERIALS, 2019, 35 (04) : E83 - E95
  • [30] Evaluation of the Marginal Fit of Virgilite Based Lithium Disilicate Ceramic Crowns: An In-Vitro Comparative Study
    Sultan, Sherif El Sayed
    Alsabilah, Khaled Ahmad Saud
    Alharbi, Bader Mahali
    Alnaser, Addulrhman Fahad
    JOURNAL OF PHARMACY AND BIOALLIED SCIENCES, 2024, 16 : S2479 - S2481