The effect of different finish line and convergence angle on the marginal fit of zirconia all-ceramic restorations

被引:0
|
作者
Ahmadzadeh, Assadolah [1 ]
Lavaf, Shirin [2 ]
Sarbazi, Amir Hossein [3 ]
Rohani, Ali [4 ]
Sepehri, Sajad [3 ]
机构
[1] Ahvaz Jundishapur Univ Med Sci, Sch Dent Med, Dept Prothodont, Ahvaz, Iran
[2] Islamic Azad Univ, Sch Dent, Dept Prosthodont, Tehran Branch, Tehran, Iran
[3] Ahvaz Jundishapur Univ Med Sci, Sch Dent Med, Dept Prothodont, Prosthodont, Ahvaz, Iran
[4] Ahvaz Jundishapur Univ Med Sci, Sch Dent Med, Ahvaz, Iran
关键词
Finish Line; Convergence Angle; Marginal Fit; CAD/CAM CROWN-COPINGS; PRECISION;
D O I
暂无
中图分类号
R-3 [医学研究方法]; R3 [基础医学];
学科分类号
1001 ;
摘要
Background and Objectives: The precise degree of marginal fit is one of the most significant criteria for the durable success of all-ceramic restorations. Since the finishing line designs and preparation angles can affect the marginal fit, the aim of the present study was to compare the effect of different finish line and convergence angle on the marginal fit of zirconia all-ceramic restorations. Materials and methods: In the present in vitro study a total of four brass dies were designed with Auto CAD software and manufactured with CNC machine (Siemens, SI Numerik 802D-SL; USA) as follow: Die A: Convergence angle of 12 degrees and radial shoulder margin, Die B: Convergence angle of 6 degrees and sloping shoulder of 135 degrees, Die C: Convergence angle of 6 degrees and radial shoulder margin, Die D: Convergence angle of 12 degrees and sloping shoulder of 135 degrees. A total of 40 plaster dies were divided in four groups of 10 (n=10), ten impressions were carried out by the double impression technique with a poly vinyl siloxane impression material for each master die. The impression was poured with type IV Plaster. A ceramic restoration was made for each plaster die then the marginal gaps were measured with SEM. Data were analysed using the two-way analysis of variance (ANOVA) and SPSS ver. 16. Results: The lowest mean (+/- standard deviation) marginal gap was observed in group A (31.9423), group D (36.03), group B (40.9537), group C (46.703), respectively. Different convergance angle had significant effect on marginal fittness (P <0.05), but marginal design had no significant effect on marginal fitness (p>0.05) and both of them together could affect on marginal fitness (p<0/05). Conclusion: The type of the finish line did not influence the marginal fit. The convergence angle influences the distance from the edge of the crown to the edge of the tooth finish line. It seems that use the convergance angle of 12 degree and radial shoulder margin can reduce the marginal gap in zirconia all-ceramic restorations.
引用
收藏
页码:678 / 684
页数:7
相关论文
共 50 条
  • [41] Effect of in vitro aging on the flexural strength and probability to fracture of Y-TZP zirconia ceramics for all-ceramic restorations
    Siarampi, Eleni
    Kontonasaki, Eleana
    Andrikopoulos, Konstantinos S.
    Kantiranis, Nikolaos
    Voyiatzis, George A.
    Zorba, Triantafillia
    Paraskevopoulos, Konstantinos M.
    Koidis, Petros
    DENTAL MATERIALS, 2014, 30 (12) : E306 - E316
  • [42] Effect of abutment shade, ceramic thickness, and coping type on the final shade of zirconia all-ceramic restorations: in vitro study of color masking ability
    Oh, Seon-Hee
    Kim, Seok-Gyu
    JOURNAL OF ADVANCED PROSTHODONTICS, 2015, 7 (05): : 368 - 374
  • [43] Clinical evaluation of marginal fit of a new experimental all-ceramic system before and after cementation
    Wolfart, S
    Wegner, SM
    Al-Halabi, A
    Kern, M
    INTERNATIONAL JOURNAL OF PROSTHODONTICS, 2003, 16 (06) : 587 - 592
  • [44] Marginal and internal fit of all-ceramic CAD/CAM crown-copings on chamfer preparations
    Bindl, A
    Mörmann, WH
    JOURNAL OF ORAL REHABILITATION, 2005, 32 (06) : 441 - 447
  • [45] Marginal adaptation of all-ceramic crowns using different luting-cements.
    Behr, M
    Rosentritt, M
    Lang, R
    Regnet, T
    Handel, G
    JOURNAL OF DENTAL RESEARCH, 2002, 81 : A421 - A421
  • [46] Marginal gap distance and cyclic fatigue loading for different all-ceramic endocrowns
    Elsayed, S. M.
    Emam, Z. N.
    Abu-Nawareg, M.
    Zidan, A. Z.
    Elsisi, H. A.
    Abuelroos, E. M.
    Fansa, H. A.
    Shokier, H. M. R.
    Elbanna, K. A.
    EUROPEAN REVIEW FOR MEDICAL AND PHARMACOLOGICAL SCIENCES, 2023, 27 (03) : 879 - 887
  • [47] Investigation of the fracture resistance of three types of zirconia posts in all-ceramic post-and-core restorations
    Jeong, SM
    Ludwig, K
    Kern, M
    INTERNATIONAL JOURNAL OF PROSTHODONTICS, 2002, 15 (02) : 154 - 158
  • [49] Digital assessment of marginal accuracy in ceramic crowns fabricated with different marginal finish line configurations
    Faruqi, Saif
    Ganji, Kiran Kumar
    Bandela, Vinod
    Nagarajappa, Anil Kumar
    Mohamed, Roshan Noor
    Al Ahmed, Muhannad
    Farhan, Mohammed
    Alwakid, Waleed Naif
    Al-Hammad, Kholood A. S.
    Alam, Mohammad Khursheed
    JOURNAL OF ESTHETIC AND RESTORATIVE DENTISTRY, 2022, 34 (05) : 789 - 795
  • [50] The effect of margin thickness, degree of convergence and bonding interlayer on the marginal failure of glass-simulated all-ceramic crowns
    Sornsuwan, Tanapon
    Swain, Michael V.