Silicon microstrip detectors in 3D technology for the sLHC

被引:0
|
作者
Parzefall, Ulrich [1 ]
Dalla Betta, Gian-Franco [2 ,3 ]
Eckert, Simon [1 ]
Eklund, Lars [4 ]
Fleta, Celeste [4 ]
Jakobs, Karl [1 ]
Kuehn, Susanne [1 ]
Pahn, Gregor [1 ]
Parkes, Chris [4 ]
Pennicard, David [4 ]
Ronchin, Sabina [5 ]
Zoboli, Andrea [2 ,3 ]
Zorzi, Nicola [5 ]
机构
[1] Univ Freiburg, Inst Phys, D-79104 Freiburg, Germany
[2] Ist Nazl Fis Nucl, I-38050 Povo, Italy
[3] Univ Trento, I-38050 Povo, Italy
[4] Univ Glasgow, Dept Phys & Astron, Glasgow G12 8QQ, Lanark, Scotland
[5] FBK irst, Ctr Mat & Microsyst, I-38050 Povo, Italy
关键词
Silicon detectors; 3D detectors; COLUMNAR ELECTRODES;
D O I
10.1016/j.nima.2009.03.122
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
The projected luminosity upgrade of the large hadron collider (LHC), the sLHC, will constitute a challenging radiation environment for tracking detectors. Massive improvements in radiation hardness are required with respect to the LHC. In the layout for the new ATLAS tracker, silicon strip detectors (SSDs) with short strips cover the region from 28 to 60cm distance to the beam. These SSDs will be exposed to fluences up to 10(15) N-eq/cm(2), hence radiation resistance is the major concern. It is advantageous to fuse the superior radiation hardness of the 3D design originally conceived for pixel-style applications with the benefits of the well-known planar technology for strip detectors. This is achieved by ganging rows of 3D columns together to form strips. Several prototype sLHC detector modules using 3D SSD with short strips, processed on p-type silicon, and LHC-speed front-end electronics from the present ATLAS semi-conductor tracker (SCT) were built. The modules were tested before and after irradiation to fluences of 10(15) N-eq/cm(2). The tests were performed with three systems: a highly focused IR-laser with Slam spot size to make position-resolved scans of the charge collection efficiency (CCE), a Sr-90 beta-source set-up to measure the signal levels for a minimum ionizing particles (MIPs), and a beam test with 180GeV pions at CERN. This article gives a brief overview of the performance of these 31) modules, and draws conclusions about options for using 3D strip sensors as tracking detectors at the sLHC. (C) 2009 Elsevier B.V. All rights reserved.
引用
收藏
页码:17 / 20
页数:4
相关论文
共 50 条
  • [41] Hybrid Detectors for Neutrons Combining Phenyl-Polysiloxanes with 3D Silicon Detectors
    Dalla Palma, Matteo
    Dalla Betta, Gian-Franco
    Collazuol, Gianmaria
    Marchi, Tommaso
    Povoli, Marco
    Mendicino, Roberto
    Boscardin, Maurizio
    Ronchin, Sabina
    Zorzi, Nicola
    Giacomini, Gabriele
    Quaranta, Alberto
    Carturan, Sara
    Cinausero, Marco
    Gramegna, Fabiana
    2013 3RD INTERNATIONAL CONFERENCE ON ADVANCEMENTS IN NUCLEAR INSTRUMENTATION, MEASUREMENT METHODS AND THEIR APPLICATIONS (ANIMMA), 2013,
  • [42] A control and monitor system for serial powering of silicon strip detectors at SLHC
    Ikegami, Y.
    Hanawa, K.
    Hara, K.
    Kohriki, T.
    Matsukuma, K.
    Terada, S.
    Unno, Y.
    2008 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (2008 NSS/MIC), VOLS 1-9, 2009, : 1881 - +
  • [43] 3D silicon pixel detectors for the High-Luminosity LHC
    Lange, J.
    Areste, M. Carulla
    Cavallaro, E.
    Foerster, F.
    Grinstein, S.
    Paz, I. Lopez
    Manna, M.
    Pellegrini, G.
    Quirion, D.
    Terzo, S.
    Furelos, D. Vazquez
    JOURNAL OF INSTRUMENTATION, 2016, 11
  • [44] 3D simulations of new low capacitance silicon pixel detectors
    Long, Qiang
    Guo, Qinwen
    Long, Zhongliang
    Li, Zheng
    PROCEEDINGS OF THE 2ND INTERNATIONAL FORUM ON MANAGEMENT, EDUCATION AND INFORMATION TECHNOLOGY APPLICATION (IFMEITA 2017), 2017, 130 : 566 - 569
  • [45] Slim edges in double-sided silicon 3D detectors
    Povoli, M.
    Bagolini, A.
    Boscardin, M.
    Dalla Betta, G. -F.
    Giacomini, G.
    Vianello, E.
    Zorzi, N.
    JOURNAL OF INSTRUMENTATION, 2012, 7
  • [46] The geometrical dependence of radiation hardness in planar and 3D silicon detectors
    Davia, C.
    Watts, S. J.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2009, 603 (03): : 319 - 324
  • [47] 3D silicon pixel detectors for the ATLAS Forward Physics experiment
    Lange, J.
    Cavallaro, E.
    Grinstein, S.
    Lopez Paz, I.
    JOURNAL OF INSTRUMENTATION, 2015, 10
  • [48] Design, simulation, production and initial characterisation of 3D silicon detectors
    Pennicard, D.
    Pellegrini, G.
    Lozano, M.
    Fleta, C.
    Bates, R.
    Parkes, C.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2009, 598 (01): : 67 - 70
  • [49] New 3D Silicon detectors for dosimetry in Microbeam Radiation Therapy
    Lerch, M. L. F.
    Dipuglia, A.
    Cameron, M.
    Fournier, P.
    Davis, J.
    Petasecca, M.
    Cornelius, I.
    Perevertaylo, V.
    Rosenfeld, A. B.
    MICRO-MINI & NANO-DOSIMETRY & INNOVATIVE TECHNOLOGIES IN RADIATION THERAPY (MMND&ITRO2016), 2017, 777
  • [50] Studies of radiation damage in silicon microstrip detectors for the D empty set silicon tracker
    Gomez, R
    Bischoff, A
    Boswell, C
    Dionson, J
    Ellison, J
    Heinson, AP
    JoffeMinor, T
    Gutierrez, P
    Guglielmo, G
    Gu, W
    Cooper, W
    Johnson, M
    Lipton, R
    Mishra, S
    Rapidis, PA
    Spiegel, L
    1995 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE RECORD, VOLS 1-3, 1996, : 867 - 871