Freshly prepared magnetic ferrite for the speciation of silver using dispersive micro-solid phase extraction and electrothermal atomic absorption spectrometry
被引:10
|
作者:
Lopez-Garcia, Ignacio
论文数: 0引用数: 0
h-index: 0
机构:
Univ Murcia, Dept Analyt Chem, Fac Chem, Reg Campus Int Excellence Campus Mare Nostrum, E-30100 Murcia, SpainUniv Murcia, Dept Analyt Chem, Fac Chem, Reg Campus Int Excellence Campus Mare Nostrum, E-30100 Murcia, Spain
Lopez-Garcia, Ignacio
[1
]
Jose Marin-Hernandez, Juan
论文数: 0引用数: 0
h-index: 0
机构:
Univ Murcia, Dept Analyt Chem, Fac Chem, Reg Campus Int Excellence Campus Mare Nostrum, E-30100 Murcia, SpainUniv Murcia, Dept Analyt Chem, Fac Chem, Reg Campus Int Excellence Campus Mare Nostrum, E-30100 Murcia, Spain
Jose Marin-Hernandez, Juan
[1
]
Hernandez-Cordoba, Manuel
论文数: 0引用数: 0
h-index: 0
机构:
Univ Murcia, Dept Analyt Chem, Fac Chem, Reg Campus Int Excellence Campus Mare Nostrum, E-30100 Murcia, SpainUniv Murcia, Dept Analyt Chem, Fac Chem, Reg Campus Int Excellence Campus Mare Nostrum, E-30100 Murcia, Spain
Hernandez-Cordoba, Manuel
[1
]
机构:
[1] Univ Murcia, Dept Analyt Chem, Fac Chem, Reg Campus Int Excellence Campus Mare Nostrum, E-30100 Murcia, Spain
A micro-solid phase extraction procedure based on the use of freshly prepared magnetic ferrite particles allows small amounts of silver in solution to be preconcentrated. Phase separation is carried out using a magnet. For a typical 10 mL water sample at a pH close to 8, the solid recovered phase (about 2 mg) is dissolved in 0.1 mL of a solution containing 8% v/v concentrated hydrofluoric acid and 4% v/v concentrated nitric acid and then introduced into an electrothermal atomizer to obtain the silver atomic absorption signal. The detection limit is 3 ng L-1 and the relative standard deviation for five measurements at the 50 ng L-1 silver level is 5.7%. Only silver(i) is retained. By repeating the procedure with another aliquot of sample after a suitable oxidation process, the discrimination between solid and dissolved silver can be achieved. The results are verified by analyzing reference water samples with a certified silver content. In addition to the application to water analysis, data for silver in items of clothing, sticking plasters and vegetables are given. The procedure is suitable for potable waters but not for seawater due to the interference caused by the high chloride concentration.
机构:
Kunming Univ Sci & Technol, Fac Life Sci & Technol, Kunming 650500, Yunnan Province, Peoples R ChinaKunming Univ Sci & Technol, Fac Life Sci & Technol, Kunming 650500, Yunnan Province, Peoples R China
Xiong, Wei
Cheng, Chunsheng
论文数: 0引用数: 0
h-index: 0
机构:
Yunnan Prov Food Safety Res Inst, Kunming 650500, Yunnan Province, Peoples R ChinaKunming Univ Sci & Technol, Fac Life Sci & Technol, Kunming 650500, Yunnan Province, Peoples R China
Cheng, Chunsheng
Yang, Yaling
论文数: 0引用数: 0
h-index: 0
机构:
Kunming Univ Sci & Technol, Fac Life Sci & Technol, Kunming 650500, Yunnan Province, Peoples R ChinaKunming Univ Sci & Technol, Fac Life Sci & Technol, Kunming 650500, Yunnan Province, Peoples R China