Towards a metamaterial approach for fast timing in PET: experimental proof-of-concept

被引:58
|
作者
Turtos, R. M. [1 ,2 ]
Gundacker, S. [1 ,2 ]
Auffray, E. [1 ,2 ]
Lecoq, P. [1 ,2 ]
机构
[1] CERN, CH-1211 Geneva 23, Switzerland
[2] Univ Milano Bicocca, Piazza Ateneo Nuovo 1, I-20126 Milan, Italy
来源
PHYSICS IN MEDICINE AND BIOLOGY | 2019年 / 64卷 / 18期
关键词
fast timing; scintillators-based detectors; TOF-PET; SEMICONDUCTOR NANOCRYSTALS; ZNO;
D O I
10.1088/1361-6560/ab18b3
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Achieving fast timing in positron emission tomography (PET) at the level of few tens of picoseconds of picoseconds is limited by the photon emission rate of existent materials with standard scintillation mechanisms. This has led to consider quantum confined excitonic sub-1 ns emission in semiconductors as a viable solution to enhance the amount of fast-emitted photons produced per gamma event. However the introduction of nanocrystals and nanostructures into the domain of radiation detectors is a challenging problem. In order to move forward along this line, the standard bulk detector geometry and readout should be updated to allow for the implementation of new materials and within others, compensate for some of their intrinsic limitations. In this paper we will cover two study cases in which a fast emitter is combined with state-of-the-art scintillators in a sampling geometry designed to provide better timing for a fraction of the 511 keV events. For this test, we use a fast plastic scintillator BC-422 able to deliver a detector time resolution (DTR) of 25 ps FWHM (equivalent coincidence time resolution CTR of 35 ps) and we combined it with LYSO or BGO 200 mu m thick plates building a sampling pixel composed by two active scintillating materials. We develop a new proof of concept readout that allows for the identification of different types of events, carrying standard or improved timing information. Results are showing a DTR of 67 ps FWHM (equivalent to a CTR of 95 ps) for one third of the events depositing 511 keV in the BGO + BC-422 3.8 x 3.8 x 3 mm(3) sampling pixel. The other two third of the 511 keV events perform like standard bulk 3 mm long BGO crystals with a time resolution of around 117 ps (equivalent to a CTR of 165 ps). For the case of LYSO + BC-422 sampling pixel, shared 511 keV events reach a DTR of 39 ps (CTR of 55 ps) in comparison to 57 ps (CTR of 83 ps) for 511 keV events fully contained in LYSO of the same size. This work is a step forward in the integration of fast semiconductor nanocrystals and nanostructures with present detector technologies.
引用
收藏
页数:12
相关论文
共 50 条
  • [31] A First Step towards a Comprehensive Approach to Harmonic Analysis of Synchronous Peripheral Volume Pulses: A Proof-of-Concept Study
    Wu, Hsien-Tsai
    Haryadi, Bagus
    Chen, Jian-Jung
    JOURNAL OF PERSONALIZED MEDICINE, 2021, 11 (12):
  • [32] Towards Chronic Liver Dysfunction Self-monitoring: a Proof-of-Concept Study
    Germanese, Danila
    Colantonio, Sara
    D'Acunto, Mario
    Brunetto, Maurizia
    Romagnoli, Veronica
    Salvati, Antonio
    2019 IEEE SYMPOSIUM ON COMPUTERS AND COMMUNICATIONS (ISCC), 2019, : 1107 - 1112
  • [33] Towards Privacy-Preserving Federated Deep Learning infrastructure : proof-of-concept
    Zhang, C.
    Choudhury, A.
    Bermejo, I.
    Dekker, A.
    RADIOTHERAPY AND ONCOLOGY, 2022, 170 : S949 - S950
  • [34] From proof-of-concept to exploitable(One step towards automatic exploitability assessment)
    Yan Wang
    Wei Wu
    Chao Zhang
    Xinyu Xing
    Xiaorui Gong
    Wei Zou
    Cybersecurity, 2
  • [35] From proof-of-concept to exploitable: (One step towards automatic exploitability assessment)
    Wang, Yan
    Wu, Wei
    Zhang, Chao
    Xing, Xinyu
    Gong, Xiaorui
    Zou, Wei
    CYBERSECURITY, 2019, 2 (01)
  • [36] A proof-of-concept study: advantages of the subxiphoid over the lateral intercostal approach
    He, Gengxu
    Yao, Tong
    Zhao, Lei
    Geng, Hong
    Ji, Qiang
    Zuo, Kun
    Luo, Yuanzhi
    Zhou, Kai
    INTERDISCIPLINARY CARDIOVASCULAR AND THORACIC SURGERY, 2024, 38 (05):
  • [37] A Proof-of-Concept Computer Vision Approach for Measurement of Tympanic Membrane Perforations
    Nwosu, Obinna
    Suresh, Krish
    Knoll, Renata
    Lee, Daniel J.
    Crowson, Matthew G.
    LARYNGOSCOPE, 2024, 134 (06): : 2906 - 2911
  • [38] An immersive view approach by secure interactive multimedia proof-of-concept implementation
    Pablo Antón
    Antonio Maña
    Antonio Muñoz
    Hristo Koshutanski
    Multimedia Tools and Applications, 2015, 74 : 8401 - 8420
  • [39] An immersive view approach by secure interactive multimedia proof-of-concept implementation
    Anton, Pablo
    Mana, Antonio
    Munoz, Antonio
    Koshutanski, Hristo
    MULTIMEDIA TOOLS AND APPLICATIONS, 2015, 74 (19) : 8401 - 8420
  • [40] Linking the Anomaly Initialization Approach to the Mapping Paradigm: A Proof-of-Concept Study
    Weber, Robin J. T.
    Carrassi, Alberto
    Doblas-Reyes, Francisco J.
    MONTHLY WEATHER REVIEW, 2015, 143 (11) : 4695 - 4713