Near-Infrared Fluorescent Activated Polymeric Probe for Imaging Intraluminal Colorectal Cancer Tumors

被引:8
|
作者
Kopansky-Groisman, Eva [1 ]
Kogan-Zviagin, Inga [1 ]
Sella-Tavor, Osnat [2 ]
Oron-Herman, Mor [3 ]
David, Ayelet [1 ]
机构
[1] Ben Gurion Univ Negev, Fac Hlth Sci, Dept Clin Biochem & Pharmacol, IL-84105 Beer Sheva, Israel
[2] Given Imaging Ltd, New Ind Pk, IL-20692 Yoqneam, Israel
[3] Sheba Med Ctr, Adv Technol Ctr, IL-52621 Tel Hashomer, Israel
关键词
CATHEPSIN-B; MISS RATE; MACROMOLECULAR THERAPEUTICS; SIDE-CHAINS; EXPRESSION; ENDOSCOPY; COLONOSCOPY; PROGRESSION; COPOLYMERS; ADENOMA;
D O I
10.1021/acs.biomac.9b00806
中图分类号
Q5 [生物化学]; Q7 [分子生物学];
学科分类号
071010 ; 081704 ;
摘要
Detection and removal of preneoplastic tumors is crucial for successful colorectal cancer (CRC) therapy. Here we describe the design of a Cathepsin B (CB)-activated polymeric probe, P-(GGFLGK-IR783), for imaging CRC tumors established by intrarectal or subcutaneous (s.c.) implantation of human colon cancer cells (SW-480 and HT-29) in mice. Multiple copies of the near-infrared fluorescent (NIRF) dye IR783 were attached to a single HPMA copolymer backbone via a CB-cleavable linker (GFLG), and the influence of the dye loading on the fluorescence quenching and activation by CB was assessed in vitro, ex vivo, and in vivo. The optimal dose and dosing regimen of P-(GGFLGK-IR783) for colonic tumor detection was determined. Increasing the IR783 loading in the copolymer from 2.5 to 20 mol % resulted in quenching of the fluorescence signal that was activated in vitro by the action of CB from different origins. Following intravenous administration, P-(GGFLGK-IR783)(7.5%) preferentially accumulated in intrarectal and s.c. implanted tumors, allowing tumor visualization after 4 h and even 48 h postadministration. Activation of P-(GGFLGK-IR783)(7.5%) by CB was clearly detected in s.c. implanted tumors, revealing about a 4-fold increase in the fluorescence signal in tumors vs healthy colon tissue. The probe containing the CB-cleavable linker produced higher fluorescence signal intensity in tumors, relative to the noncleavable probe. These results indicate that P-(GGFLGK-IR783)(7.5%) may aid in detecting CRC tumors and can help to guide selective removal of polyps during colonoscopic procedures.
引用
收藏
页码:3547 / 3556
页数:10
相关论文
共 50 条
  • [31] A near-infrared fluorescent probe for sulfide detection
    Yang, Xiaojing
    Zhang, Chengkai
    Shen, Liqiao
    Bao, Haibo
    Xu, Jingwei
    Fang, Xuexun
    Zhao, Yongxia
    Yang, Wei
    SENSORS AND ACTUATORS B-CHEMICAL, 2017, 242 : 332 - 337
  • [32] Glutathione-activated near-infrared II fluorescent probe for lung metastatic diagnosis and intraoperative imaging of tumor
    Wang, Yonghai
    Zhao, Guiling
    Liu, Yu
    Wang, Rui
    Xing, Yanlong
    Dou, Kun
    Yu, Fabiao
    SENSORS AND ACTUATORS B-CHEMICAL, 2025, 426
  • [33] Biomedical Imaging of Colorectal Cancer by Near Infrared Fluorescent Nanoparticles
    Tivony, Ran
    Larush, Liraz
    Sela-Tavor, Osnat
    Magdassi, Shlomo
    JOURNAL OF BIOMEDICAL NANOTECHNOLOGY, 2014, 10 (06) : 1041 - 1048
  • [34] Near-Infrared Fluorescent Sorbitol Probe for Targeted Photothermal Cancer Therapy
    Lee, Sungsu
    Jung, Jin Seok
    Jo, Gayoung
    Yang, Dae Hyeok
    Koh, Yang Seok
    Hyun, Hoon
    CANCERS, 2019, 11 (09)
  • [35] Construction of GSH activated near-infrared fluorescent and photoacoustic dual-modal probe for in vivo tumor imaging
    Qin, Jingcan
    Tian, Hao
    Kong, Fei
    Guo, Yuanyuan
    Du, Wenxian
    Zhang, Chuan
    Gu, Hongmei
    Li, Yuehua
    SENSORS AND ACTUATORS B-CHEMICAL, 2022, 371
  • [36] A near-infrared fluorescent probe with viscosity sensitivity in lysosome for cancer visualization
    Yong Wang
    Lixian Fu
    Yiyun Tan
    Yue Ding
    Weixia Qing
    Analytical and Bioanalytical Chemistry, 2024, 416 : 341 - 348
  • [37] A near-infrared fluorescent probe with viscosity sensitivity in lysosome for cancer visualization
    Wang, Yong
    Fu, Lixian
    Tan, Yiyun
    Ding, Yue
    Qing, Weixia
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2024, 416 (02) : 341 - 348
  • [38] Activatable Two-Photon Near-Infrared Fluorescent Probe Tailored toward Peroxynitrite In Vivo Imaging in Tumors
    Wang, Weiwei
    Xiong, Jianhua
    Song, Xinjian
    Wang, Zhao
    Zhang, Fan
    Mao, Zhiqiang
    ANALYTICAL CHEMISTRY, 2020, 92 (19) : 13305 - 13312
  • [39] Near-infrared fluorescent labeled peptosome for application to cancer imaging
    Tanisaka, Hiroki
    Kizaka-Kondoh, Shinae
    Makino, Akira
    Tanaka, Shotaro
    Hiraoka, Masahiro
    Kimura, Shunsaku
    BIOCONJUGATE CHEMISTRY, 2008, 19 (01) : 109 - 117
  • [40] A near-infrared, highly specific NQO1-activated turn-on fluorescent probe for the detection and imaging of cancer cells in vivo
    Punganuru, Surendra Reddy
    Arutla, Viswanath
    Srivenugopal, Kalkunte S.
    CANCER RESEARCH, 2019, 79 (13)