Non-contact mapping

被引:0
|
作者
Schneider, MAE
Schmitt, C
机构
[1] Herzkatheter EPU, Deutsch Herzzentrum, D-80636 Munich, Germany
[2] Herzkatheter EPU, Med Klin 1, D-80636 Munich, Germany
来源
关键词
ablation; atrial flutter; atrial fibrillation; ventricular tachycardia; non-contact mapping;
D O I
暂无
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
The non-contact mapping device (Ensite, Endocardial Solution) enables a simultaneous, spatial detection of the myocardial depolarization. An isopotential map is visualized in the 3D reconstruction of the cardiac chamber. The analysis of focal premature beats, of unstable arrhythmias and of macro reentry mechansims is possible. The current article demonstrates the use of the non-contact mapping device for analysis and ablation of atrial flutter, premature beat associated atrial fibrillation and of ventricular tachycardias.
引用
收藏
页码:177 / 185
页数:9
相关论文
共 50 条
  • [31] Mapping of atrial activation and tachyarrhythmias using a non-contact right atrial catheter
    Kadish, A
    Hauck, J
    Beatty, G
    Schilling, R
    Pederson, B
    Voth, E
    Gornick, C
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1997, 29 (02) : 2070 - 2070
  • [32] Global electrophysiological and hemodynamic assessment of ventricular pacing employing non-contact mapping
    Nicholas D. Skadsberg
    Daniel R. Kaiser
    Trent M. Fischer
    Paul A. Iaizzo
    Journal of Interventional Cardiac Electrophysiology, 2009, 26 : 185 - 194
  • [33] Ventricular tachycardia ablation in organic heart disease guided by non-contact mapping
    Katsivas, A.
    Koutouzis, M.
    Nikolidakis, S.
    Kyriakides, Z. S.
    EUROPEAN HEART JOURNAL, 2006, 27 : 451 - 451
  • [34] Characteristics of the conduction of the left atrium in atrial fibrillation using non-contact mapping
    Takashima, Hideo
    Kumagai, Koichiro
    Matsumoto, Naomichi
    Yasuda, Tomoo
    Nakashima, Hideko
    Yamaguchi, Yoshio
    Hida, Satoru
    Muraoka, Soichi
    Mitsutake, Chiharu
    Miura, Shin-Ichiro
    Saku, Keijiro
    JOURNAL OF CARDIOLOGY, 2010, 56 (02) : 166 - 175
  • [35] Localization of pulmonary vein ectopic activity using a non-contact mapping system
    Packer, DL
    Johnson, SB
    CIRCULATION, 1999, 100 (18) : 373 - 373
  • [36] Non-contact mapping to guide radiofrequency ablation of atypical right atrial flutter
    Tai, CT
    Liu, TY
    Lee, PC
    Lin, YJ
    Chang, MS
    Chen, SA
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2004, 44 (05) : 1080 - 1086
  • [37] Radiofrequency Catheter Ablation Using Non-Contact Mapping for Inappropriate Sinus Tachycardia
    Chad E. Bonhomme
    Florin T. Deger
    Jeff Schultz
    Steve S. Hsu
    Journal of Interventional Cardiac Electrophysiology, 2004, 10 : 159 - 163
  • [38] Feasibility of combined non-contact and electroanatomical mapping for guiding ablation of complex arrhythmias
    Munger, TM
    Friedman, PA
    Grice, SK
    Hammill, SC
    Packer, DL
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2000, 35 (02) : 126A - 126A
  • [39] Accuracy of reproduction of human endocardial electrograms by a novel non-contact mapping system
    Schilling, RJ
    Peters, NS
    Davies, DW
    CIRCULATION, 1997, 96 (08) : 2155 - 2155
  • [40] Global electrophysiological and hemodynamic assessment of ventricular pacing employing non-contact mapping
    Skadsberg, Nicholas D.
    Kaiser, Daniel R.
    Fischer, Trent M.
    Iaizzo, Paul A.
    JOURNAL OF INTERVENTIONAL CARDIAC ELECTROPHYSIOLOGY, 2009, 26 (03) : 185 - 194