Device management of arrhythmias after Fontan conversion

被引:17
|
作者
Tsao, Sabrina [1 ,3 ]
Deal, Barbara J. [1 ,3 ]
Backer, Carl L. [2 ,4 ]
Ward, Kendra [1 ,3 ]
Franklin, Wayne H. [1 ,3 ]
Mavroudis, Constantine [5 ]
机构
[1] Childrens Mem Hosp, Div Cardiol, Chicago, IL 60614 USA
[2] Childrens Mem Hosp, Div Cardiovasc Thorac Surg, Chicago, IL 60614 USA
[3] Northwestern Univ, Dept Pediat, Feinberg Sch Med, Chicago, IL 60611 USA
[4] Northwestern Univ, Feinberg Sch Med, Dept Surg, Chicago, IL 60611 USA
[5] Case Western Reserve Univ, Cleveland Clin Childrens Hosp, Cleveland Clin Lerner Sch Med, Ctr Pediat & Congenital Heart Dis, Cleveland, OH 44106 USA
来源
关键词
MAZE PROCEDURE; OPERATION;
D O I
10.1016/j.jtcvs.2008.11.066
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objectives: We assessed our pacemaker strategy, use of antitachycardia therapies, generator longevity, and need for programming changes in patients having Fontan conversion with arrhythmia surgery. Methods: Between 1994 and 2008, of 121 consecutive patients having Fontan conversion and arrhythmia surgeries, 120 patients underwent pacemaker implantation at the time of Fontan conversion (mean age 22.9 +/- 8.1 years). Prior pacemakers were in place in 32/120 (26.7%) patients. Between 1994 and 1998, single-chamber atrial antitachycardia pacemakers were implanted ( n = 12); atrial rate-responsive pacemakers (n = 31) were implanted between 1998 and 2002. Dual-chamber rate-responsive pacemakers (n = 16) were used between 2002 and 2003, and subsequently dual-chamber antitachycardia pacemakers (n = 61) have become the pacemaker of choice. Leads have evolved from transatrial endocardial leads to epicardial unipolar and subsequently bipolar leads. Results: Among 87 patients with adequate follow-up, all are currently atrially paced at a minimum lower rate >= 70 beats per minute. Single-chamber atrial pacemakers were implanted in 43 (antitachycardia in 12), and dual-chamber pacemakers in 77 (antitachycardia in 61); multisite ventricular leads were placed in 7 patients. Far-field R-wave sensing in 78.6% of unipolar atrial leads led to use of epicardial bipolar leads. Late atrioventricular block (24%) led to routine implantation of dual-chamber pacemakers. Antitachycardia pacing was utilized in 7%. One patient required acute lead revision and 4 required late upgrade to dual-chamber pacemakers. There was no pacemaker-related infection. Twenty patients required generator change, and the mean device longevity was 7.53 years. Conclusions: Customized pacemaker therapy can optimize management of patients following Fontan conversion. Device longevity is excellent. Based on our experience with 120 Fontan conversions, we recommend placement of a dual-chamber antitachycardia pacemaker with bipolar steroid-eluting epicardial leads in all patients at the time of the conversion.
引用
收藏
页码:937 / 940
页数:4
相关论文
共 50 条
  • [41] Late Arrhythmias Following Fontan Surgery
    Deal, Barbara J.
    WORLD JOURNAL FOR PEDIATRIC AND CONGENITAL HEART SURGERY, 2012, 3 (02) : 194 - 200
  • [42] Atrial Arrhythmias in Adults with Fontan Palliation
    Matthew Laubham
    Ben Blais
    Anna N. Kamp
    Cardiology and Therapy, 2023, 12 : 473 - 487
  • [43] Current management of late failure after classic Fontan modifications: Fontan conversions
    Erek, E
    Yalcinbas, YK
    Sarioglu, A
    Sarioglu, T
    THORACIC AND CARDIOVASCULAR SURGEON, 2006, 54 (01): : 21 - 25
  • [44] Hemoptysis after CardioSEAL device ernbolization of a venous collateral after the Fontan operation
    Pastuszko, P
    Rome, JJ
    Gleason, MM
    Bellah, RD
    Montenegro, LM
    Gaynor, JW
    JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2005, 129 (06): : 1447 - 1448
  • [45] ARRHYTHMIAS AFTER THE FONTAN OPERATION IN THE CURRENT ERA: DOES THE EXTRACARDIAC CONDUIT REDUCE THE INCIDENCE OF POST-OPERATIVE ARRHYTHMIAS?
    Lasa, Javier
    Glatz, Andrew
    Shah, Maully
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2011, 57 (14) : E431 - E431
  • [46] Beyond Fontan conversion: Surgical therapy of arrhythmias including patients with associated complex congenital heart disease
    Deal, BJ
    Mavroudis, C
    Backer, CL
    ANNALS OF THORACIC SURGERY, 2003, 76 (02): : 542 - 553
  • [47] Ventricular Arrhythmias After Left Ventricular Assist Device
    Nakahara, Shashima
    Chien, Christopher
    Gelow, Jill
    Dalouk, Khidir
    Henrikson, Charles A.
    Mudd, James
    Stecker, Eric C.
    CIRCULATION-ARRHYTHMIA AND ELECTROPHYSIOLOGY, 2013, 6 (03): : 648 - 654
  • [48] Are Arrhythmias Adequately Incorporated into Studies on Long-Term Outcomes After the Fontan Operation?
    Pexton, Natalie
    Balaji, Seshadri
    PEDIATRIC CARDIOLOGY, 2025,
  • [49] Intra/extracardiac fenestrated modification leads to lower incidence of arrhythmias after the Fontan operation
    Sinha, Pranava
    Zurakowski, David
    He, Dingchao
    Yerebakan, Can
    Freedenberg, Vicki
    Moak, Jeffrey P.
    Jonas, Richard A.
    JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2013, 145 (03): : 678 - 682
  • [50] Fontan conversion with novel direct ablation after childbirth: Report of a case
    Tsukasa Ozawa
    Takeshiro Fujii
    Noritsugu Shiono
    Satoshi Hamada
    Hiroshi Masuhara
    Masanori Hara
    Yuki Sasaki
    Tomoyuki Katayanagi
    Katsunori Yoshihara
    Yoshifumi Okano
    Shinichi Takatsuki
    Tsutomu Saji
    Nobuya Koyama
    Yoshinori Watanabe
    Surgery Today, 2011, 41 : 1684 - 1688