Adaptive Frequency-Based Reference Compensation Current Control Strategy of Shunt Active Power Filter for Unbalanced Nonlinear Loads

被引:9
|
作者
Chen, Cheng-I [1 ]
Lan, Chien-Kai [2 ]
Chen, Yeong-Chin [3 ]
Chen, Chung-Hsien [4 ]
机构
[1] Natl Cent Univ, Dept Elect Engn, Taoyuan 32001, Taiwan
[2] Natl Changhua Univ Educ, Dept Mechatron Engn, Changhua 50074, Taiwan
[3] Asia Univ, Dept Comp Sci & Informat Engn, Taichung 41354, Taiwan
[4] Met Ind Res & Dev Ctr, Taichung 40768, Taiwan
关键词
adaptive frequency detection technique; reference compensation current control strategy; shunt active power filter (SAPF); power quality; IEEE Standard 519-2014; DC-link voltage; hardware-in-the-loop (HIL); HARMONICS;
D O I
10.3390/en12163080
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
The shunt active power filter (SAPF) is an effective means for the modification of power quality. However, the compensation performance of SAPF would be deteriorated when the unbalanced nonlinear loads are present in the power system. To enhance the compensation performance of SAPF, the adaptive frequency-based reference compensation current control strategy is proposed in this paper. The proposed solution procedure can be divided into three stages including adaptive frequency detection, phase synchronization, and adaptive compensation. With the tracking of power system frequency, the phase synchronization for the SAPF compensation can be effectively modified under the power variation of unbalanced nonlinear loads. Based on the correct synchronization phase angle, the reference compensation current of SAPF can be accurately obtained with the adaptive linear neural network (ALNN) in the stage of adaptive compensation. In addition, the direct current (DC)-link voltage of SAPF can also be effectively regulated to maintain the compensation performance. To verify the effectiveness of the proposed adaptive frequency-based reference compensation current control strategy, the comprehensive case studies implemented with the hardware-in-the-loop (HIL) mechanism are performed to examine the compliance with the specification limits of IEEE Standard 519-2014. The experimental results reveal that the performance of proposed SAPF control strategy is superior to that of the traditional instantaneous reactive power compensation control technique (p-q method) and sliding discrete Fourier transform (DFT).
引用
收藏
页数:14
相关论文
共 50 条
  • [21] Compensation of supply current harmonics, reactive power, and unbalanced load current balance in the closed-loop control of a shunt active power filter
    Bielecka, Agata
    Wojciechowski, Daniel
    SCIENTIFIC JOURNALS OF THE MARITIME UNIVERSITY OF SZCZECIN-ZESZYTY NAUKOWE AKADEMII MORSKIEJ W SZCZECINIE, 2020, 61 (133): : 9 - 16
  • [22] Shunt active power filter with harmonic current control strategy.
    Doval, J
    Nogueiras, A
    Peñalver, CM
    Lago, A
    PESC 98 RECORD - 29TH ANNUAL IEEE POWER ELECTRONICS SPECIALISTS CONFERENCE, VOLS 1 AND 2, 1998, : 1631 - 1635
  • [23] Double hysteresis current control strategy for shunt active power filter
    Electric Power College, South China University of Technology, Guangzhou 510640, China
    不详
    Dianli Xitong Baohu yu Kongzhi, 2009, 9 (60-64):
  • [24] Current Loop Control Strategy Research for Shunt Active Power Filter
    Chen Yuqing
    Zhang Kehu
    Ji Zhaojun
    Zhen Hongfen
    Kong Feng
    2009 INTERNATIONAL CONFERENCE ON ELECTRICAL MACHINES AND SYSTEMS, VOLS 1-3, 2009, : 698 - +
  • [25] Performance Tolerant Control of Shunt Active Power Filter Under Unbalanced Nonlinear Load
    Frifita, K.
    Boussak, M.
    Naamane, A.
    M'Sirdi, N.
    2015 16TH INTERNATIONAL CONFERENCE ON SCIENCES AND TECHNIQUES OF AUTOMATIC CONTROL AND COMPUTER ENGINEERING (STA), 2015, : 278 - 283
  • [26] Predictive Tuned Filter based Reference Current Generation for Shunt Active Power Filter under Distorted and Unbalanced Supply Voltage
    Gali, Vijayakumar
    Gupta, Nitin
    Gupta, R. A.
    2018 NATIONAL POWER ENGINEERING CONFERENCE (NPEC), 2018,
  • [27] Power Quality Enhancement for Nonlinear Unbalanced Loads through Improved Active Power Filter Control
    Youssef, Tarek A.
    Elsayed, Ahmed T.
    Berzoy, Alberto
    Mohammed, Osama A.
    IECON 2014 - 40TH ANNUAL CONFERENCE OF THE IEEE INDUSTRIAL ELECTRONICS SOCIETY, 2014, : 5202 - 5207
  • [28] Nonlinear Loads Compensation Using a Shunt Active Power Filter Controlled by Feedforward Neural Networks
    Flores-Garrido, Juan L.
    Salmeron, Patricio
    Gomez-Galan, Juan A.
    APPLIED SCIENCES-BASEL, 2021, 11 (16):
  • [29] Research on control strategy for three-phase three-wire shunt active power filter under unbalanced loads
    Wei, Xue-liang
    Dai, Ke
    Peng, Hua-liang
    Kang, Yong
    Chen, Jian
    EUROCON 2007: THE INTERNATIONAL CONFERENCE ON COMPUTER AS A TOOL, VOLS 1-6, 2007, : 372 - 376
  • [30] Model reference adaptive control design for a shunt active power filter system
    Shyu, Kuo-Kai
    Yang, Ming-Ji
    Chen, Yen-Mo
    Lin, Yi-Fei
    IECON 2006 - 32ND ANNUAL CONFERENCE ON IEEE INDUSTRIAL ELECTRONICS, VOLS 1-11, 2006, : 2720 - +