X-ray phase contrast and absorption imaging for the quantification of transient cavitation in high-speed nozzle flows

被引:16
|
作者
Karathanassis, I. K. [1 ,2 ]
Heidari-Koochi, M. [1 ]
Zhang, Q. [3 ]
Hwang, J. [4 ]
Koukouvinis, P. [1 ,2 ]
Wang, J. [3 ]
Gavaises, M. [1 ]
机构
[1] City Univ London, Sch Math Comp Sci & Engn, London EC1V 0HB, England
[2] Sandia Natl Labs, Combust Res Facil, Livermore, CA 94550 USA
[3] Argonne Natl Lab, Adv Photon Source, Lemont, IL 60439 USA
[4] Mississippi State Univ, Dept Mech Engn, Ctr Adv Vehicular Syst CAVS, Starkville, MS 39762 USA
基金
英国工程与自然科学研究理事会;
关键词
CENTRIFUGAL PUMP; VISUALIZATION; DYNAMICS; EROSION; NOISE; MECHANISMS; BEHAVIOR; GAS; PIV;
D O I
10.1063/5.0038475
中图分类号
O3 [力学];
学科分类号
08 ; 0801 ;
摘要
High-flux synchrotron radiation has been employed in a time-resolved manner to characterize the distinct topology features and dynamics of different cavitation regimes arising in a throttle orifice with an abrupt flow-entry contraction. Radiographs obtained though both x-ray phase-contrast and absorption imaging have been captured at 67 890 frames per second. The flow lies in the turbulent regime (Re=35 500), while moderate (CN=2.0) to well-established (CN=6.0) cavitation conditions were examined encompassing the cloud and vortical cavitation regimes with pertinent transient features, such as cloud-cavity shedding. X-ray phase-contrast imaging, exploiting the shift in the x-ray wave phase during interactions with matter, offers sharp-refractive index gradients in the interface region. Hence, it is suitable for capturing fine morphological fluctuations of transient cavitation structures. Nevertheless, the technique cannot provide information on the quantity of vapor within the orifice. Such data have been obtained utilizing absorption imaging, where beam attenuation is not associated with scattering and refraction events, and hence can be explicitly correlated with the projected vapor thickness in line-of-sight measurements. A combination of the two methods is proposed as it has been found that it is capable of quantifying the vapor content arising in the complex nozzle flow while also faithfully illustrating the dynamics of the highly transient cavitation features.
引用
收藏
页数:20
相关论文
共 50 条
  • [41] X-ray phase contrast imaging at MAMI
    M. El-Ghazaly
    H. Backe
    W. Lauth
    G. Kube
    P. Kunz
    A. Sharafutdinov
    T. Weber
    The European Physical Journal A - Hadrons and Nuclei, 2006, 28 : 197 - 208
  • [42] X-ray phase-contrast imaging
    Endrizzi, Marco
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2018, 878 : 88 - 98
  • [43] Revealing the origins of vortex cavitation in a Venturi tube by high speed X-ray imaging
    Soyama, Hitoshi
    Liang, Xiaoyu
    Yashiro, Wataru
    Kajiwara, Kentaro
    Asimakopoulou, Eleni Myrto
    Bellucci, Valerio
    Birnsteinova, Sarlota
    Giovanetti, Gabriele
    Kim, Chan
    Kirkwood, Henry J.
    Koliyadu, Jayanath C. P.
    Letrun, Romain
    Zhang, Yuhe
    Ulicny, Jozef
    Bean, Richard
    Mancuso, Adrian P.
    Villanueva-Perez, Pablo
    Sato, Tokushi
    Vagovic, Patrik
    Eakins, Daniel
    Korsunsky, Alexander M.
    ULTRASONICS SONOCHEMISTRY, 2023, 101
  • [44] Research on Nozzle Geometry Measurement with Synchrotron Radiation X-ray Phase Contrast Imaging Technique
    Xu, Cangsu
    Luo Qiyuan
    Jian, Ma
    Fang, Qi
    Xu Yifan
    MATERIALS, TRANSPORTATION AND ENVIRONMENTAL ENGINEERING, PTS 1 AND 2, 2013, 779-780 : 1007 - +
  • [45] X-RAY PHASE CONTRAST IMAGING OF CAVITATION AND DISCHARGED LIQUID JET IN NOZZLES WITH VARIOUS SIZES
    Prasetya, Rubby
    Sou, Akira
    Moon, Seoksu
    Pratama, Raditya Hendra
    Wada, Yoshitaka
    Yokohata, Hideaki
    ATOMIZATION AND SPRAYS, 2019, 29 (01) : 59 - 78
  • [46] High Aspect Ratio Gratings for X-Ray Phase Contrast Imaging
    Mohr, Juergen
    Grund, Thomas
    Kunka, Danays
    Kenntner, Johannes
    Leuthold, Juerg
    Meiser, Jan
    Schulz, Joachim
    Walter, Marco
    INTERNATIONAL WORKSHOP ON X-RAY AND NEUTRON PHASE IMAGING WITH GRATINGS, 2012, 1466 : 41 - 50
  • [47] Development of an X-ray interferometer for high-resolution phase-contrast X-Ray imaging
    Hirano, K
    Momose, A
    JAPANESE JOURNAL OF APPLIED PHYSICS PART 2-LETTERS, 1999, 38 (12B): : L1556 - L1558
  • [48] Quantification of porosity in composite plates using planar X-ray phase contrast imaging
    Shoukroun, D.
    Massimi, L.
    Endrizzi, M.
    Nesbitt, A.
    Bate, D.
    Fromme, P.
    Olivo, A.
    NDT & E INTERNATIONAL, 2023, 139
  • [49] Optimal contrast for X-ray phase-contrast imaging
    College of Medical Instrument, University of Shanghai Science and Technology, Shanghai 200093, China
    不详
    Guangzi Xuebao, 2008, 6 (1217-1220):
  • [50] The effect of transient needle lift on the internal flow and near-nozzle spray characteristics for modern GDI systems investigated by high-speed X-ray imaging
    Mamaikin, Dmitrii
    Knorsch, Tobias
    Rogler, Philipp
    Wang, Jin
    Wensing, Michael
    INTERNATIONAL JOURNAL OF ENGINE RESEARCH, 2022, 23 (02) : 300 - 318