In soil measurement of radiation dose caused by X-ray computed tomography

被引:10
|
作者
Lippold, Eva [1 ]
Kleinau, Philip [2 ]
Blaser, Sebastian R. G. A. [1 ]
Schluter, Steffen [1 ]
Phalempin, Maxime [1 ]
Vetterlein, Doris [1 ,3 ]
机构
[1] UFZ Helmholtz Ctr Environm Res, Dept Soil Syst Sci, Theodor Lieser Str 4, D-06120 Halle, Germany
[2] Mir Technol AWST GmbH, Dosimetrieserv, Otto Hahn Ring 6, D-81739 Munich, Germany
[3] Martin Luther Univ Halle Wittenberg, Soil Sci, Von Seckendorff Pl 3, D-06120 Halle, Germany
关键词
dosimeter; irradiation damage; soil X‐ ray absorption; X‐ ray CT;
D O I
10.1002/jpln.202000276
中图分类号
S3 [农学(农艺学)];
学科分类号
0901 ;
摘要
Radiation damage to plants through X-ray exposure has been reported to impair root growth. The literature on the critical dose for growth impairment is inconclusive, partly as dose measurements in soil are scarce. Here we fill this gap and show that the dose in a typical single pot scan amounts to 1.2 Gy. In addition, we demonstrate the shortcomings of estimating the dose from scan settings using the RadPro Calculator and highlight the efficient reduction of X-ray exposure by a lead shield.
引用
收藏
页码:343 / 345
页数:3
相关论文
共 50 条
  • [31] Industrial X-ray computed tomography
    Pechstein, Torsten
    TM-TECHNISCHES MESSEN, 2020, 87 (02) : 79 - 80
  • [32] Dynamic X-ray computed tomography
    Bonnet, S
    Koenig, A
    Roux, S
    Hugonnard, P
    Guillemaud, R
    Grangeat, P
    PROCEEDINGS OF THE IEEE, 2003, 91 (10) : 1574 - 1587
  • [33] Design for X-Ray Computed Tomography
    Moroni, Giovanni
    Petro, Stefano
    29TH CIRP DESIGN CONFERENCE 2019, 2019, 84 : 173 - 178
  • [34] Industrial computed X-ray tomography
    Luthi, T
    Flisch, A
    Wyss, P
    INSIGHT, 1998, 40 (03) : 196 - 197
  • [35] X-ray computed tomography of the heart
    Wijesekera, Nevin T.
    Duncan, Mark K.
    Padley, Simon P. G.
    BRITISH MEDICAL BULLETIN, 2010, 93 (01) : 49 - 67
  • [36] Assessment of the measurement procedure for dimensional metrology with X-ray computed tomography
    Kraemer, Alexandra
    Lanza, Gisela
    14TH CIRP CAT 2016 - CIRP CONFERENCE ON COMPUTER AIDED TOLERANCING, 2016, 43 : 362 - 367
  • [37] Quantitative Measurement of the Bone Density by X-Ray Micro Computed Tomography
    Binkowski, M.
    Davis, G. R.
    Wrobel, Z.
    Goodship, A. E.
    6TH WORLD CONGRESS OF BIOMECHANICS (WCB 2010), PTS 1-3, 2010, 31 : 856 - +
  • [38] Measurement of density variations in tablets using X-ray computed tomography
    Sinka, IC
    Burch, SF
    Tweed, JH
    Cunningham, JC
    INTERNATIONAL JOURNAL OF PHARMACEUTICS, 2004, 271 (1-2) : 215 - 224
  • [39] Review of the influence of noise in X-ray computed tomography measurement uncertainty
    Rodriguez-Sanchez, Angela
    Thompson, Adam
    Koerner, Lars
    Brierley, Nick
    Leach, Richard
    PRECISION ENGINEERING-JOURNAL OF THE INTERNATIONAL SOCIETIES FOR PRECISION ENGINEERING AND NANOTECHNOLOGY, 2020, 66 : 382 - 391
  • [40] APPLICATION OF X-RAY COMPUTED TOMOGRAPHY IN THE EVALUATION OF SOIL POROSITY IN SOIL MANAGEMENT SYSTEMS
    Beraldo, Jose M. G.
    Scannavino Junior, Francisco De A.
    Cruvinel, Paulo E.
    ENGENHARIA AGRICOLA, 2014, 34 (06): : 1162 - 1174