In soil measurement of radiation dose caused by X-ray computed tomography

被引:10
|
作者
Lippold, Eva [1 ]
Kleinau, Philip [2 ]
Blaser, Sebastian R. G. A. [1 ]
Schluter, Steffen [1 ]
Phalempin, Maxime [1 ]
Vetterlein, Doris [1 ,3 ]
机构
[1] UFZ Helmholtz Ctr Environm Res, Dept Soil Syst Sci, Theodor Lieser Str 4, D-06120 Halle, Germany
[2] Mir Technol AWST GmbH, Dosimetrieserv, Otto Hahn Ring 6, D-81739 Munich, Germany
[3] Martin Luther Univ Halle Wittenberg, Soil Sci, Von Seckendorff Pl 3, D-06120 Halle, Germany
关键词
dosimeter; irradiation damage; soil X‐ ray absorption; X‐ ray CT;
D O I
10.1002/jpln.202000276
中图分类号
S3 [农学(农艺学)];
学科分类号
0901 ;
摘要
Radiation damage to plants through X-ray exposure has been reported to impair root growth. The literature on the critical dose for growth impairment is inconclusive, partly as dose measurements in soil are scarce. Here we fill this gap and show that the dose in a typical single pot scan amounts to 1.2 Gy. In addition, we demonstrate the shortcomings of estimating the dose from scan settings using the RadPro Calculator and highlight the efficient reduction of X-ray exposure by a lead shield.
引用
收藏
页码:343 / 345
页数:3
相关论文
共 50 条
  • [1] Dose in x-ray computed tomography
    Kalender, Willi A.
    PHYSICS IN MEDICINE AND BIOLOGY, 2014, 59 (03): : R129 - R150
  • [2] X-ray computed tomography of frozen soil
    Torrance, J. K.
    Elliot, T.
    Martin, R.
    Heck, R. J.
    COLD REGIONS SCIENCE AND TECHNOLOGY, 2008, 53 (01) : 75 - 82
  • [3] Radiation dose estimation for pencil beam X-ray luminescence computed tomography imaging
    Romero, Ignacio O.
    Li, Changqing
    JOURNAL OF X-RAY SCIENCE AND TECHNOLOGY, 2021, 29 (05) : 773 - 784
  • [4] Porosity Measurement Method by X-ray Computed Tomography
    Prokop, Josef
    Sveda, Libor
    Jancarek, Alexandr
    Pina, Ladislav
    FRACTOGRAPHY OF ADVANCED CERAMICS III, 2009, 409 : 402 - 405
  • [5] Measurement of voids in composites by X-ray Computed Tomography
    Nikishkov, Yuri
    Airoldi, Luca
    Makeev, Andrew
    COMPOSITES SCIENCE AND TECHNOLOGY, 2013, 89 : 89 - 97
  • [6] Effects of X-Ray Dose On Rhizosphere Studies Using X-Ray Computed Tomography
    Zappala, Susan
    Helliwell, Jonathan R.
    Tracy, Saoirse R.
    Mairhofer, Stefan
    Sturrock, Craig J.
    Pridmore, Tony
    Bennett, Malcolm
    Mooney, Sacha J.
    PLOS ONE, 2013, 8 (06):
  • [7] Evaluation of Computed Tomography X-Ray Beam Dose Profiles
    Civa, Lejla M.
    Beganovic, Adnan
    Redzic, Mahira
    Lasic, Ivan
    Gazdic-Santic, Maja
    Skopljak-Beganovic, Amra
    Jasic, Rahima
    Vegar-Zubovic, Sandra
    PROCEEDINGS OF THE INTERNATIONAL CONFERENCE ON MEDICAL AND BIOLOGICAL ENGINEERING, CMBEBIH 2019, 2020, 73 : 137 - 141
  • [8] MINIMIZATION OF DOSE LOAD IN ALGORITHMS OF X-RAY COMPUTED TOMOGRAPHY
    Bulavin, L. A.
    Zabashta, Yu F.
    Motolyha, O., V
    UKRAINIAN JOURNAL OF PHYSICS, 2019, 64 (04): : 282 - 286
  • [9] Photon Counting Computed Tomography with the Radiation Dose of a Chest X-Ray: Feasibility and Diagnostic Yield
    Dettmer, Sabine
    Werncke, Thomas
    Mitkovska, Violeta Nikolova
    Brod, Torben
    Joean, Oana
    Vogel-Claussen, Jens
    Wacker, Frank
    Welte, Tobias
    Rademacher, Jessica
    RESPIRATION, 2024, 103 (02) : 88 - 94
  • [10] X-ray computed tomography
    Kalender, Willi A.
    PHYSICS IN MEDICINE AND BIOLOGY, 2006, 51 (13): : R29 - R43