Open-capsule intraocular lens to prevent posterior capsule opacification

被引:10
|
作者
Katsuki, Yoko [1 ,2 ]
Matsushima, Hiroyuki [1 ]
Mukai, Koichiro [1 ]
Watabiki, Satoshi [1 ]
Aose, Masamoto [1 ]
Terauchi, Wataru [1 ]
Nagamoto, Toshiyuki [3 ]
Senoo, Tadashi [1 ]
机构
[1] Dokkyo Med Univ, Dept Ophthalmol, 880 Kitakobayashi, Mibu, Tochigi 3210293, Japan
[2] HOYA Corp, Div Med, Tokyo, Japan
[3] Nagamoto Eye Clin, Tokyo, Japan
来源
关键词
OPTIC EDGE DESIGN; ENDOCAPSULAR EQUATOR RING; EPITHELIAL-CELLS; BENDING RING; AQUEOUS-HUMOR; LONG-TERM; SILICONE; SHARP; INHIBITION; EFFICACY;
D O I
10.1016/j.jcrs.2018.12.022
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: To develop a single-piece open-capsule intraocular lens (IOL) that can be inserted through a small incision and that prevents posterior capsule opacification (PCO) by expanding the capsule and circulating aqueous humor into the capsular bag. Setting: Department of Ophthalmology, Dokkyo Medical University, Tochigi, Japan. Design: Experimental study. Method: Using the same hydrophobic acrylic material as the NY-60 IOL, a prototype open-capsule IOL was constructed. The IOL has a single optic and 2 haptics, with a 2.8 mm high spacer and holes through which aqueous humor circulates into the capsular bag by separating the anterior capsule from the posterior capsule and expanding the capsule. The open-capsule IOL or NY-60 (as a control group) was inserted in rabbit eyes. Posterior capsule opacification development was evaluated by measuring the thickness of the cell layer at the center of the posterior capsule on histopathologic specimens and statistically comparing the thickness between the open-capsule IOL group and control group. Results: The open-capsule IOL could be inserted through a 3.2 mm corneal incision using a D cartridge. The mean thickness of the cell layer at the center of the posterior capsule was 4.78 mu m +/- 2.61 (SD) in the open-capsule IOL group and 101.14 +/- 25.19 mu m in the control group and was significantly smaller in the open-capsule IOL group. Conclusion: The prototype single-piece IOL could be implanted through a small incision and prevented PCO by expanding the lens capsule and circulating aqueous humor into the capsular bag. (C) 2019 Published by Elsevier Inc. on behalf of ASCRS and ESCRS
引用
收藏
页码:1007 / 1012
页数:6
相关论文
共 50 条
  • [1] Further Enhancement of Intraocular Open-Capsule Devices for Prevention of Posterior Capsule Opacification
    Slutzky, Lee
    Kleinmann, Guy
    TRANSLATIONAL VISION SCIENCE & TECHNOLOGY, 2018, 7 (01):
  • [2] Posterior capsule opacification: is intraocular lens material a factor?
    Arshinoff, Steve
    CANADIAN JOURNAL OF OPHTHALMOLOGY-JOURNAL CANADIEN D OPHTALMOLOGIE, 2009, 44 (02): : 136 - 137
  • [3] Effect of intraocular lens design on posterior capsule opacification
    Buehl, Wolf
    Findl, Oliver
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2008, 34 (11): : 1976 - 1985
  • [4] Effect of intraocular lens and anterior capsule opening type on posterior capsule opacification
    Birinci, H
    Kuruoglu, S
    Öge, I
    Öge, F
    Acar, E
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 1999, 25 (08): : 1140 - 1146
  • [5] Influence of intraocular lens implantation on anterior capsule contraction and posterior capsule opacification
    Aose, Masamoto
    Matsushima, Hiroyuki
    Mukai, Koichiro
    Katsuki, Yoko
    Gotoh, Norihito
    Senoo, Tadashi
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2014, 40 (12): : 2128 - 2133
  • [6] Posterior capsule opacification after implantation of a hydrogel intraocular lens
    Hayashi, K
    Hayashi, H
    BRITISH JOURNAL OF OPHTHALMOLOGY, 2004, 88 (02) : 182 - 185
  • [7] Relationship between intraocular lens biomaterials and posterior capsule opacification
    Ursell, PG
    Spalton, DJ
    Pande, MV
    Hollick, EJ
    Barman, S
    Boyce, J
    Tilling, K
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 1998, 24 (03): : 352 - 360
  • [8] Rate of posterior capsule opacification in eyes with the Akreos intraocular lens
    Khandwala, Mona A.
    Marjnovic, Branka
    Kotagiri, Ajay K.
    Teimory, Masoud
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2007, 33 (08): : 1409 - 1413
  • [9] Relationship between posterior capsule opacification and intraocular lens biocompatibility
    Saika, S
    PROGRESS IN RETINAL AND EYE RESEARCH, 2004, 23 (03) : 283 - 305
  • [10] Effect of silicone intraocular lens design on posterior capsule opacification
    Yanagawa, H
    Kobayakawa, S
    Nagamine, K
    Tochikubo, T
    Miura, M
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2002, 43 : U88 - U88